KONG -Y
NameDescriptionContent
Location:

ABB 3BSE069463-600 PP885 touch screen

From: | Author:kongjiang | Time :2024-09-14 | 829 Browse: | 🔊 Click to read aloud ❚❚ | Share:

ABB 3BSE069463-600 PP885 touch screen

Section 1 Introduction

General

All Panel 800 Version 6 are developed to satisfy the demands of human-machinecommunication. Built-in functions such as displaying and controlling text, dynamicindication, time channels, alarm and recipe handling are included.

The Panel 800 Version 6 works primarily in an object-oriented way, making it easyto understand and use. Configuration is carried out on a PC using the Panel Builderconfiguration tool. The project can then be transferred and stored in the operatorpanel itself.

Various types of automation equipment such as PLCs, servos or drives can beconnected to the Panel 800 Version 6. In this manual, the term “the controller”refers to the connected equipment.

This manual explains how to install the operator panel. Please refer to thePanel Builder Programming and Installation manual for further information.Description User DocumentationInitial release of PP885 3BSE069463-600Amended UL battery information 3BSE069463-600 Rev AUpdated UL information 3BSE069463-600 Rev B

Disposal requirements under WEEE regulations 3BSE069463-600 Rev C

Section 2 Safety Precautions Both the installer and the owner and/or operator of the operator panel must read and understand this installation manual. General • Read the safety precautions carefully. • Check the delivery for transportation damage. If damage is found, notify the supplier as soon as possible. • The supplier is not responsible for modified, altered or reconstructed equipment. • Use only parts and accessories manufactured according to specifications of the supplier. • Read the installation and operating instructions carefully before installing, using or repairing the operator panel. • Never allow fluids, metal filings or wiring debris to enter any openings in the operator panel. This may cause fire or electrical shock. • Only qualified personnel may operate the operator panel. • Storing the operator panel where the temperature is lower/higher than recommended in this manual can cause the LCD display liquid to congeal/become isotopic. • The LCD display liquid contains a powerful irritant. In case of skin contact, wash immediately with plenty of water. In case of eye contact, hold the eye open, flush with plenty of water and get medical attention. • The figures in this manual serves an illustrative purpose. Because of the many variables associated with any particular installation, the supplier cannot assume responsibility for actual use based on the figures. 3BSE069463-600 Rev D 11 UL and cUL Installation Section 2 Safety Precautions • The supplier neither guarantees that the operator panel is suitable for your particular application, nor assumes responsibility for your product design, installation or operation. • It is recommended to turn on and shut down the operator panel at least once before installing any components/cards or before connecting the operator panel to external devices, like for example serial devices

During Installation • The operator panel is designed for stationary installation on a planar surface, where the following conditions are fulfilled: – no high explosive risks – no strong magnetic fields – no direct sunlight – no large, sudden temperature changes • Install the operator panel according to the accompanying installation instructions. • Ground the operator panel according to the accompanying installationinstructions. • Only qualified personnel may install the operator panel. • Separate the high voltage, signal and supply cables. • Make sure that the voltage and polarity of the power source is correct beforeconnecting the operator panel to the power outlet. • Peripheral equipment must be appropriate for the application and location. • In a Zone 2 environment, this equipment shall be installed in an enclosure thatprovides a degree of protection not less than IP 54 or greater than IP 65 inaccordance with IEC/EN 600079-0. TheIPrating of the equipment is limited tothe IP rating of the enclosure it is to be installed into. • In a Zone 22 environment, this equipment shall be installed in an enclosurethat provides a degree of protection not less than IP 64 or greater than IP 65 inaccordance with IEC/EN 600079-0. The IPrating of the equipment is limited tothe IP rating of the enclosure it is to be installed into.During Use • Keep the operator panel clean. • Emergency stop and other safety functions may not be controlled from theoperator panel. • Do not use excessive force or sharp objects when operating the touch screen.14 3BSE069463-600 Rev DSection 2 Safety Precautions Appearance of Air in Touch ScreenService and Maintenance • Only qualified personnel should carry out repairs. • The agreed warranty applies. • Before carrying out any cleaning or maintenance operations, disconnect theequipment from the electrical supply. • Clean the display and surrounding front cover with a soft cloth and milddetergent. • Replacing the battery incorrectly may result in explosion. Only use batteriesrecommended by the supplier. During the warranty period, the battery needs tobe replaced by an authorized ABB service center.Dismantling and Scrapping • The operator panel or parts thereof shall be recycled according to localregulations. • The following components contain substances that might be hazardous to healthand the environment: lithium battery, electrolytic capacitor and display.Appearance of Air in Touch ScreenThe layer structure of the touch screen contains air and in rare cases appearance ofbubbles can arise. This is purely cosmetic and does not affect any functionality of theoperator panel. The appearance can occur under certain environmental conditionssuch as temperature, humidity, and atmospheric pressure.

  • SAMSUNG SMRTD-8 RTD Pt100 Temperature Input Module (8CH)
  • SAMSUNG SMAIC-8 Analog Input Module (8CH)
  • SAMSUNG SMDO-8 Digital Output Module (8CH)
  • SAMSUNG SMDI-8 Digital Input Module (8CH)
  • SAMSUNG SMCPU-08 Central Processing Unit Controller
  • Embedded MXM GPU Modules EGX-MXM-A4500 ADLINK
  • Embedded MXM GPU Modules EGX-MXM-AD2000 ADLINK
  • ADLINK Embedded MXM GPU Modules EGX-MXM-AD3500
  • ADLINK Embedded MXM GPU Modules EGX-MXM-AD5000
  • Embedded MXM GPU Modules EGX-MXM-AD ADLINK
  • Embedded MXM GPU Modules MXM-AXe ADLINK
  • ADLINK Embedded MXM GPU Modules EGX-MXM-BW500
  • Embedded MXM GPU Modules EGX-MXM-BW2000 ADLINK
  • ADLINK Embedded MXM GPU Modules EGX-MXM-BW4000
  • Embedded MXM GPU Modules EGX-MXM-BW5000 ADLINK
  • SAMSUNG SSAS-PRO SPTB-AI dedicated analog input terminal board
  • SAMSUNG SSAS-PRO SPTB-DO dedicated digital output terminal board
  • SAMSUNG SSAS-PRO SPTB-DI dedicated terminal board
  • SAMSUNG SSAS-PRO SPBK-X32-12 Heavy-duty 8-slot system chassis backplane
  • SAMSUNG SSAS-PRO SPBK-X32-08 Heavy-duty 8-slot system chassis backplane
  • SAMSUNG SSAS-PRO SPSU-X32 heavy-duty rack-mounted
  • SAMSUNG SSAS-PRO SPIRU-16 versatile universal mixed I/O module
  • SAMSUNG SSAS-PRO SPRI-16 RTD Temperature Input Module
  • SAMSUNG SSAS-PRO SPAO-8 Analog Output Module
  • SAMSUNG SSAS-PRO SPAI-16 Analog Input Module
  • SAMSUNG SSAS-PRO SPRDO-16 Relay digital output module
  • SAMSUNG SSAS-PRO SPDO-16 (Transistor Digital Output Module)
  • SAMSUNG SSAS-PRO SPDI-24 high-density digital input module
  • SAMSUNG SPDI-16 (Digital Input Module)
  • ADLINK 3U Enclosures & Systems AD-3100
  • Power Supplies cPS-H300S/AC ADLINK
  • CPCI Serial Peripheral cPCI-A3H10 ADLINK
  • ADLINK CPCI Serial Peripheral cPCI-A3XMC
  • CPCI Serial Peripheral cPCI-A3H20 ADLINK
  • CPCI Serial Peripheral cPCI-A3MXM ADLINK
  • ADLINK CPCI Serial Peripheral cPCI-A3COM
  • ADLINK CPCI Serial Peripheral cPCI-A3USB
  • ADLINK CPCI Serial Peripheral cPCI-A3ETH
  • CPCI Serial Peripheral cPCI-A3CAN ADLINK
  • 3U CompactPCI Serial Blades cPCI-A3525 Series
  • 3U CompactPCI Serial Blades cPCI-A3535 Series ADLINK
  • CompactPCI Backplanes cBP-6402 ADLINK
  • ADLINK CompactPCI Backplanes cBP-6402R
  • ADLINK CompactPCI Backplanes cBP-6105R
  • CompactPCI Backplanes cBP-6405R ADLINK
  • CompactPCI Backplanes cBP-6108F ADLINK
  • CompactPCI Backplanes cBP-6108R ADLINK
  • CompactPCI Backplanes cBP-6014R ADLINK
  • ADLINK 6U Enclosures & Systems cPCIS-6130R
  • ADLINK 6U Enclosures & Systems cPCIS-6230R/ 6240R Series
  • ADLINK 6U Enclosures & Systems cPCIS-6235R
  • ADLINK 6U Enclosures & Systems cPCIS-6400X Series
  • ADLINK 6U Enclosures & Systems cPCIS-6400U Series
  • ADLINK 6U Enclosures & Systems cPCIS-6418U
  • ADLINK 6U Enclosures & Systems cPCIS-3300BLS
  • ADLINK 6U Enclosures & Systems cPCIS-3320/AC
  • ADLINK Power Supplies cPS-H640/AC
  • ADLINK Power Supplies cPS-H640/48
  • ADLINK 6U Rear Transition Modules cPCI-R6100 Series
  • ADLINK 6U Rear Transition Modules cPCI-R6002 Series
  • ADLINK 6U Rear Transition Modules cPCI-R6600 Series
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6660
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6636(KL) Series
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6640 Series
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6540 Series
  • ADLINK CompactPCI Backplanes cBP-3064
  • ADLINK CompactPCI Backplanes cBP-3213PR
  • ADLINK 3U Enclosures & Systems cPCIS-2500 Series
  • ADLINK 3U Enclosures & Systems cPCIS-2630 Series
  • ADLINK 3U Enclosures & Systems cPCIS-2632 Series
  • ADLINK 3U Enclosures & Systems cPCIS-2642 Series
  • ADLINK U Enclosures & Systems cPCIS-2633 Series
  • ADLINK U Enclosures & Systems cPCIS-ET1100 Series
  • ADLINK Power Supplies cPS-H325/AC
  • ADLINK Power Supplies cPS-H325/48
  • ADLINK Power Supplies cPS-H325/110
  • ADLINK Power Supplies cPS-H325/24
  • ADLINK PCI-7841/cPCI-7841 Dual-port Isolated CAN Interface Cards
  • ADLINK Peripherals & Accessories cPCI-3548
  • ADLINK Peripherals & Accessories cPCI-8301
  • ADLINK Peripherals & Accessories cPCI-3W10
  • ADLINK Analog Output cPCI-6208/6216 Series
  • ADLINK Multi-Function DAQ cPCI-9116
  • ADLINK 3U CompactPCI Blades CT-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3630
  • ADLINK 3U CompactPCI Blades cPCI-3640 Series
  • 3U CompactPCI Blades cPCI-3520 Series
  • ADLINK IMB-M42H ATX Motherboards
  • Adlink PCIe-GIE74 /PCIe-GIE74V Frame Grabbers / Video Capture Cards
  • ADLINK USB-1605 Removable screw terminal blocks or high-density D-Sub
  • Adlink ETX-NR667-L7400/LXE ETX Module
  • ADLINK NuPRO-842LV/P industrial control motherboard
  • ADLINK cPCI-8994 Serial Communication
  • ADLINK / PCI-7432 Digital I/O
  • ADLINK IEC-915GV Compact industrial-grade fanless embedded system
  • ADLINK ADLINK, PLX / PCI-7296 Digital I/O
  • ADLINK HPCI-14S12U 0040 Backplane Selection Guide
  • ADLINK MXE-5500 /MXE-5501/M16G (G) Fanless Embedded Computer
  • Adlink Multi-Function DAQ PCI-9112
  • ADLINK NuPRO-852LV Control Board
  • ADLINK CompactPCI cPCI-7432R Digital I/O Module
  • ADLINK NUPRO-E320LV PICMG Single Board Computers
  • ADLINK PICMG Single Board Computers NuPRO-E72
  • ADLINK PICMG Single Board Computers NuPRO-865
  • Vibro-Meter Rack VM600SYSMK2-ABE04x 6U 19-inch rack Mk2 system
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 (single card) 600-044L
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 600-04
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045L
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045
  • Vibro-Meter I/O interface card  IOCN Mk2    600-051
  • Vibro-Meter CPU controller   CPUM Mk2  600-050
  • Vibro-Meter I/O interface card    IOC10 Mk2 (rear card)    600-046
  • Vibro-Meter Temperature / Analog Acquisition  AMC10 Mk2  600-042
  • Vibro-Meter I/O interface card IOC4 Mk2 600-043
  • Vibro-Meter Protective measuring card MPC4 Mk2 SIL2 601-041-A10
  • Vibro-Meter Protective measuring card MPC4 Mk2 601-041-A0
  • Vibro-Meter PSU-VM600 VM600 Rack Power Module
  • Vibro-Meter ABE056 - 1U ultra-thin single-rack
  • Vibro-Meter ABE046 - 6U 19-inch rack
  • Vibro-Meter ABE045 - 6U 19-inch rack
  • Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)
  • Vibro-Meter ABE042 6U 19-inch rack (4 slots)
  • Vibro-Meter I/O interface card XIO16T
  • Vibro-Meter XMC16 16-channel combustion monitoring card
  • Vibro-Meter XMV16 - 16-channel vibration condition monitoring card
  • Vibro-Meter RLC16 Relay Card