 3. Create an I/O configuration. Use the SST ProfiBus Configuration Tool or Siemens COM PROFIBUS to create a configuration for the I/O you are scanning. Refer to the software’s online help for complete details on creating a configuration with one of these tools

4. Download the ProfiBus software module. Refer to the Hardware User’s Guide. Use the loader program pfbinst to download the ProfiBus module to the card. For example, if the card is installed at the default port and memory addresses, the command is: vmeinst vmeprofi 

 5. Configure the card as a DP Master Run the sample program cometcnf to configure the card as a DP master using the binary file you exported from the SST ProfiBus Configuration Tool or COM PROFIBUS. If the card is installed at port address 250 and the file is called test.2bf, the command is: cometcnf 250 test 

 6. Put the card online. Run the sample program vmecmd to put the card online. If the card is installed at port address 250, the command is: vmecmd 250 online 

 7. Scan I/O. Run the sample program dpmon to display and edit data. If the card is installed at port address 250, the command is: dpmon 250 From the program menu:- Press A to view the active station list, then press P to see what passive stations (in this case, I/O slaves) are present on the network.- Press M to view configured slaves. Press R to put the card in run mode. Select a slave and press Enter to view and edit its I/O data.-   Press E from the main menu to view diagnostic counters.

DP Slave Prior to performing this procedure, refer to the Hardware User’s Guide for more detailed information on installing the card. Use the following steps to bring a 5136-PFB-VME online as a DP slave. 

 1. Install the card. (Refer to the Hardware user’s Guide). Check the switch settings on the card and install the card in the computer. 

 2. Install the software, choosing one of the three options described here. 

 •     Run the batch file install.bat on the distribution disk to install the distribution software. This batch file install the software in the directory ssvmedos. 

 •    Run the setup.exe program from the appropriate Windows disk to install the SST ProfiBus Configuration Tool. 

 •    Run the batch file cometupdcomet to install the files for configuring the 5136-PFB-VME under COM PROFIBUS. 

 3. Download the ProfiBus software module. Use the loader program vmeinst to download the ProfiBus module to the card. For example: vmeinst vmeprofi 

 4. Create a network configuration. Edit the sample file netslv.ncf file to set the network parameters. At minimum, you need to set:- baud rate- station address 

 5. Create a slave configuration. Edit the sample file slave.scf to set the slave parameters. At minimum, you need to set:- number of inputs (bytes)- number of outputs (bytes)

6. Configure the card’s network parameters. Run the sample program pbnetcnf to configure the card’s network parameters. If the card is installed at port address 250 and the file is called netslave.ncf, the command is: pbnetcnf 250 netslave 

 7. Configure the card as a slave Run the sample program dpslvcnf to configure the card as a DP slave. If the card is installed at port address 250 and the file is called slave.scf, the command is: dpslvcnf 250 slave 8. Put the card online Run the sample program pbcmd to put the card online. If the card is installed at port address 250, the command is: vmecmd 250 online 9. Access the data. Run the sample program dpmon to access data. If the card is installed at port address 250, the command is: dpmon 250 From the program menu:- Press S to view the slave data.- Press D to view slave diagnostics- Press E to view diagnostic counters.


  • SAMSUNG SSAS-PRO SPTB-AI dedicated analog input terminal board
  • SAMSUNG SSAS-PRO SPTB-DO dedicated digital output terminal board
  • SAMSUNG SSAS-PRO SPTB-DI dedicated terminal board
  • SAMSUNG SSAS-PRO SPBK-X32-12 Heavy-duty 8-slot system chassis backplane
  • SAMSUNG SSAS-PRO SPBK-X32-08 Heavy-duty 8-slot system chassis backplane
  • SAMSUNG SSAS-PRO SPSU-X32 heavy-duty rack-mounted
  • SAMSUNG SSAS-PRO SPIRU-16 versatile universal mixed I/O module
  • SAMSUNG SSAS-PRO SPRI-16 RTD Temperature Input Module
  • SAMSUNG SSAS-PRO SPAO-8 Analog Output Module
  • SAMSUNG SSAS-PRO SPAI-16 Analog Input Module
  • SAMSUNG SSAS-PRO SPRDO-16 Relay digital output module
  • SAMSUNG SSAS-PRO SPDO-16 (Transistor Digital Output Module)
  • SAMSUNG SSAS-PRO SPDI-24 high-density digital input module
  • SAMSUNG SPDI-16 (Digital Input Module)
  • ADLINK 3U Enclosures & Systems AD-3100
  • Power Supplies cPS-H300S/AC ADLINK
  • CPCI Serial Peripheral cPCI-A3H10 ADLINK
  • ADLINK CPCI Serial Peripheral cPCI-A3XMC
  • CPCI Serial Peripheral cPCI-A3H20 ADLINK
  • CPCI Serial Peripheral cPCI-A3MXM ADLINK
  • ADLINK CPCI Serial Peripheral cPCI-A3COM
  • ADLINK CPCI Serial Peripheral cPCI-A3USB
  • ADLINK CPCI Serial Peripheral cPCI-A3ETH
  • CPCI Serial Peripheral cPCI-A3CAN ADLINK
  • 3U CompactPCI Serial Blades cPCI-A3525 Series
  • 3U CompactPCI Serial Blades cPCI-A3535 Series ADLINK
  • CompactPCI Backplanes cBP-6402 ADLINK
  • ADLINK CompactPCI Backplanes cBP-6402R
  • ADLINK CompactPCI Backplanes cBP-6105R
  • CompactPCI Backplanes cBP-6405R ADLINK
  • CompactPCI Backplanes cBP-6108F ADLINK
  • CompactPCI Backplanes cBP-6108R ADLINK
  • CompactPCI Backplanes cBP-6014R ADLINK
  • ADLINK 6U Enclosures & Systems cPCIS-6130R
  • ADLINK 6U Enclosures & Systems cPCIS-6230R/ 6240R Series
  • ADLINK 6U Enclosures & Systems cPCIS-6235R
  • ADLINK 6U Enclosures & Systems cPCIS-6400X Series
  • ADLINK 6U Enclosures & Systems cPCIS-6400U Series
  • ADLINK 6U Enclosures & Systems cPCIS-6418U
  • ADLINK 6U Enclosures & Systems cPCIS-3300BLS
  • ADLINK 6U Enclosures & Systems cPCIS-3320/AC
  • ADLINK Power Supplies cPS-H640/AC
  • ADLINK Power Supplies cPS-H640/48
  • ADLINK 6U Rear Transition Modules cPCI-R6100 Series
  • ADLINK 6U Rear Transition Modules cPCI-R6002 Series
  • ADLINK 6U Rear Transition Modules cPCI-R6600 Series
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6660
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6636(KL) Series
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6640 Series
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6540 Series
  • ADLINK CompactPCI Backplanes cBP-3064
  • ADLINK CompactPCI Backplanes cBP-3213PR
  • ADLINK 3U Enclosures & Systems cPCIS-2500 Series
  • ADLINK 3U Enclosures & Systems cPCIS-2630 Series
  • ADLINK 3U Enclosures & Systems cPCIS-2632 Series
  • ADLINK 3U Enclosures & Systems cPCIS-2642 Series
  • ADLINK U Enclosures & Systems cPCIS-2633 Series
  • ADLINK U Enclosures & Systems cPCIS-ET1100 Series
  • ADLINK Power Supplies cPS-H325/AC
  • ADLINK Power Supplies cPS-H325/48
  • ADLINK Power Supplies cPS-H325/110
  • ADLINK Power Supplies cPS-H325/24
  • ADLINK PCI-7841/cPCI-7841 Dual-port Isolated CAN Interface Cards
  • ADLINK Peripherals & Accessories cPCI-3548
  • ADLINK Peripherals & Accessories cPCI-8301
  • ADLINK Peripherals & Accessories cPCI-3W10
  • ADLINK Analog Output cPCI-6208/6216 Series
  • ADLINK Multi-Function DAQ cPCI-9116
  • ADLINK 3U CompactPCI Blades CT-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3630
  • ADLINK 3U CompactPCI Blades cPCI-3640 Series
  • 3U CompactPCI Blades cPCI-3520 Series
  • ADLINK IMB-M42H ATX Motherboards
  • Adlink PCIe-GIE74 /PCIe-GIE74V Frame Grabbers / Video Capture Cards
  • ADLINK USB-1605 Removable screw terminal blocks or high-density D-Sub
  • Adlink ETX-NR667-L7400/LXE ETX Module
  • ADLINK NuPRO-842LV/P industrial control motherboard
  • ADLINK cPCI-8994 Serial Communication
  • ADLINK / PCI-7432 Digital I/O
  • ADLINK IEC-915GV Compact industrial-grade fanless embedded system
  • ADLINK ADLINK, PLX / PCI-7296 Digital I/O
  • ADLINK HPCI-14S12U 0040 Backplane Selection Guide
  • ADLINK MXE-5500 /MXE-5501/M16G (G) Fanless Embedded Computer
  • Adlink Multi-Function DAQ PCI-9112
  • ADLINK NuPRO-852LV Control Board
  • ADLINK CompactPCI cPCI-7432R Digital I/O Module
  • ADLINK NUPRO-E320LV PICMG Single Board Computers
  • ADLINK PICMG Single Board Computers NuPRO-E72
  • ADLINK PICMG Single Board Computers NuPRO-865
  • Vibro-Meter Rack VM600SYSMK2-ABE04x 6U 19-inch rack Mk2 system
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 (single card) 600-044L
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 600-04
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045L
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045
  • Vibro-Meter I/O interface card  IOCN Mk2    600-051
  • Vibro-Meter CPU controller   CPUM Mk2  600-050
  • Vibro-Meter I/O interface card    IOC10 Mk2 (rear card)    600-046
  • Vibro-Meter Temperature / Analog Acquisition  AMC10 Mk2  600-042
  • Vibro-Meter I/O interface card IOC4 Mk2 600-043
  • Vibro-Meter Protective measuring card MPC4 Mk2 SIL2 601-041-A10
  • Vibro-Meter Protective measuring card MPC4 Mk2 601-041-A0
  • Vibro-Meter PSU-VM600 VM600 Rack Power Module
  • Vibro-Meter ABE056 - 1U ultra-thin single-rack
  • Vibro-Meter ABE046 - 6U 19-inch rack
  • Vibro-Meter ABE045 - 6U 19-inch rack
  • Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)
  • Vibro-Meter ABE042 6U 19-inch rack (4 slots)
  • Vibro-Meter I/O interface card XIO16T
  • Vibro-Meter XMC16 16-channel combustion monitoring card
  • Vibro-Meter XMV16 - 16-channel vibration condition monitoring card
  • Vibro-Meter RLC16 Relay Card
  • Vibro-Meter IRC4 Intelligent Relay Card
  • Vibro-Meter IOCR2 input/output rear interface card
  • Vibro-Meter CPUR2 Central Processing and Controller Card
  • Vibro-Meter I/O interface card  -  IOCR
  • VIBRO-METER CPU controller CPUR
  • VIBRO-METER IOCN 200-585-000-322 I/O interface card
  • VIBRO-METER IOCN 200-585-000-321 I/O Interface Card
  • VIBRO-METER 200-595-074-323 VM600 system CPU management card, non-redundant
  • VIBRO-METER CPUM 200-595-074-322 CPU Controller
  • VIBRO-METER CPU controller CPUM 200-595-070-321
  • Vibro-Meter IOC8T VM600 Mk1 I/O Interface Card
  • Vibro-Meter AMC8 Analog Monitoring Card
  • VIBRO-METER IOC4G2 I/O interface card
  • VIBRO-METER MPC4G2 Protective measuring card
  • VIBRO-METER IOC4T 200-560-101-017 VM600 Mk1 Isolated I/O Interface Card, equipped with MPC4