KONG -Y
NameDescriptionContent
Location:

GE Multilin 750/760 - Legacy Feeder Protection System

From:GE | Author:kongjiang | Time :2025-12-18 | 648 Browse: | 🔊 Click to read aloud ❚❚ | Share:

GE Multilin 750/760 - Legacy

Feeder Protection System

Manufacturing for 750/760 has been discontinued. As an alternative, please refer to the 850.

The 750/760 Feeder Protection System, a member of the SR Family of protection relays, with draw out capability intended for primary protection and management of distribution feeders. 

The 750/760 has specific features for industrial environments, including a drawout case to limit downtime during maintenance and conformal coating for harsh environments.

Key Benefits

Easy to use protection supported by industry leading software

Accurate built-in metering functions

I/O monitoring - improve uptime

IRIG-B time synchronization, event reports, waveform capture, data logger

Minimize replacement time

Draw-out construction

Simplify testing - Built in simulation features

Supports industry protocols such as DNP & Modbus

Optional 10MB Ethernet port

Complete monitoring - Analog I/O, Full metering

Leading edge technology - Flash memory for product field upgrade

Optional conformal coating for Harsh Environments

Applications

Primary protection and control for distribution feeders on solidly grounded, high impedance grounded or resonant grounded systems

Bus blocking/Interlocking schemes

High-speed fault detection for arc flash

Throw over schemes (bus transfer scheme)

Load shedding schemes based on voltage and frequency elements

Back-up protection for transmission lines, feeders and transformers

Distributed Generation (DG) interconnect protection

Key Features

Directional time, instantaneous phase overcurrent protection

Directional time, instantaneous ground overcurrent protection

Directional sensitive ground and Restricted Earth Fault protection

Negative sequence overcurrent protection

Bus and line undervoltage

Overvoltage

Neutral overvoltage

Underfrequency/Frequency decay

Reverse power protection

Synchrocheck

Automatic bus transfer

Manual control

Cold load pickup control

Power factor control

4 shot recloser (760 only)

Power factor control

Synchrocheck - V, f, Hz, & dead-source

Protection and Control

The 750/760 Feeder Protection System is a digital relay intended for the management and primary protection and control of distribution feeders. 

This easy to use relay provides comprehensive protection functions for feeders and back up protection for bus, transformers and transmission lines at a reduced product life cycle cost.

Key Features

Metering - current,voltage, sequence components, power, energy, voltage

Breaker operation & trip failure

Event recording - 128 time tagged events

Total breaker arcing current

Ambient temperature /analog transducer input

Analog transducer input

Oscillography & Data Logger - 10 records up to 32 power cycles

Simulation mode and playback capability.

Monitoring and Metering

The 750/760 features advanced monitoring and metering functions which include:

Fault Locator

The relay uses captured data to calculate the type, distance to and the impedance of the fault. Records of the last 10 faults are stored.

Breaker Conditions

The relay calculates the per-phase wear on the breaker contacts to establish a threshold. When the breaker maintenance threshold is exceeded the relay can trigger an alarm. 

An alarm is also generated if the relay detects that the supervisory trickle current is not present. A failure to respond to an open or close signal in a programmed time can be used to generate an alarm.

VT Failure

The VT failure feature monitors each phase of input voltage, generating an alarm and sending the programmed output signals when a failure is detected.

Analog Inputs

Any external quantity may be monitored via an auxiliary current input. Two analog input level monitoring elements and two rate-of-change elements are available. 

When the measured quantity exceeds the pickup level, the relay can trigger an alarm or signal an output.

Event Recording

The relay captures and stores the last 512 events, recording the time, date, cause, and system parameters. Events may be recorded selectively by category, so that only events of interest are recorded.

Oscillography

A block of configurable volatile memory can be used for recording samples of the AC input voltages and current, and the status of logic inputs and output relays. 

This memory can be configured between the ranges of two to 16 blocks with 16 to 256 power frequency cycles of data respectively. 

The amount of pre-event data recorded is set by the user. Trace memory recording can be triggered by operation of selected features or logic inputs.

Trip Counter

The number of breaker trip operations is recorded, and can be displayed for statistical purposes (useful for units without operation counters).

Key Features

Networking interfaces - 10Mbps Ethernet, RS232. RS485 and RS422 ports

Ethernet port, 10Mbps

Multiple protocols - ModBus™ RTU, ModBus™ RTU, TCP/IP, DNP 3.0 Level 2

Advanced Communications

The 750/760 is equipped with three standard serial communications ports, one RS232 located in the front panel, and two RS485/RS422 in the rear of the relay. A rear Ethernet port is also available as an optional feature. 

The front panel port allows easy local computer access. The rear ports provide remote communications or connection to a DCS, SCADA, or PLC. 

he baud rate of all the serial ports is variable from 300 to 19.200 bps. The optional Ethernet port can be used to connect the 750/760 to 10 Mbps Ethernet networks. 

The 750/760 supports ModBus® RTU, DNP3.0 Level 2. and ModBus® RTU TCP/IP protocols.

The three serial ports support ModBus® RTU protocol, while any one of the two rear ports but not both can be configured to support DNP 3.0 Level 2. 

The optional Ethernet port supports ModBus® RTU via TCP/IP protocol. The communication system of the 750/760 is designed to allow simultaneous communication via all ports.

Using Ethernet as the physical media to integrate the 750/760 to Local or Wide Area Networks, replaces a multipoint wired network (e.g., serial Modbus®), and eliminates expensive leased or dial-up connections, reducing monthly operating costs.

User Interface

Various user interfaces facilitate operation of the 750.

Display

A 40 character display allows access to setpoints, actual values, and diagnostic messages generated by a trip or alarm condition. The 750 can display 30 user-selected messages during keypad inactivity.

Indicators

Twenty LEDs indicate relay status, system status, and trip and alarm conditions.

IRIG-B Input

This feature provides time synchronization via standard GPS clock inputs.

EnerVista Software

The EnerVista™ Suite is an industry-leading set of software programs that simplifies every aspect of using the 750/760 relay. 

The EnerVista™ suite provides all the tools to monitor the status of your protected asset, maintain the relay, and integrate information measured by the 750 into DCS or SCADA monitoring systems. 

Convenient COMTRADE and Sequence of Events viewers are an integral part of the 750 Setup software included with every 750 relay, to carry out postmortem event analysis to ensure proper protection system operation.

Retrofit Kit

Explore the 8 Series Retrofit Kit

Retrofit Existing SR 750 Devices to the Multilin 850 in Minutes

Traditionally, retrofitting an existing relay has been a challenging, time consuming task often requiring re-engineering, new drawings, panel modifications, re-wiring and re-testing.

The 8 Series Retrofit Kit provides a quick, 3-step solution to upgrade previously installed SR 735 or SR 750/760 Devices. 

With the new 8 Series Retrofit Kit users are able to install the 850 Feeder Management System without modifying existing cutouts and wiring, and without any drawing changes or re-engineering time.



  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • ADLINK SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO  HSL-4XMO-TB-D103  HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • ADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink PICMG Single Board Computers NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 ICMG Single Board Computers
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC