Performance & Scalability
The A2 provides scalable, wire-rate performance in support of the bandwidth-intensive and delay-sensitive requirements of today’s demanding applications. Along with a switch capacity of 17.6Gbps, the A2 provides up to 48 10/100Base-T or 24 100Base-FX Ethernet ports as well as 2 10/100/1000 Ethernet ports, which can be used as uplink or stacking connections. As many as 8 A2s can be interconnected in a single stack to create a virtual switch that provides 140.8Gbps of capacity and up to 384 10/100Base-T or 192 100Base-FX Ethernet ports as well as 32 10/100/1000 Ethernet ports for uplink or stacking connections.
MAC Address Table Size
8,000
VLANs
4,096 VLAN IDs
1,024 VLAN entries per stack
Embedded Services
Ingress Rate Limiting
IP TOS Rewrite
Layer 2/3/4 classification
Multilayer Packet Processing
Switching Services
IEEE 802.1D – MAC Bridges
IEEE 802.1s – Multiple Spanning Trees
IEEE 802.1t – 802.1D Maintenance
IEEE 802.1w – Rapid Spanning Tree Reconvergence
IEEE 802.3ab – GE over Twisted Pair
IEEE 802.3ad – Link Aggregation
IEEE 802.3af – PoE
IEEE 802.3i - 10Base-T
IEEE 802.3u - 100Base-T, 100Base-FX
IEEE 802.3z - GE over fiber
Full/half duplex auto-sense support on all ports
IGMP Snooping v1/v2/v3
Jumbo Frame support (9,216 bytes)
Loop Protection
One-to-One and Many-to-One Port Mirroring
Port Description
Protected Ports
Per-Port Broadcast Suppression
Spanning Tree Backup Root
STP Pass Thru
VLAN Support
Generic Attribute Registration Protocol (GARP)
Generic VLAN Registration Protocol (GVRP)
IEEE 802.1p – Traffic Management/ Mapping to 8 queues
IEEE 802.1q – VLAN tagging
IEEE 802.1v – Protocol-based VLANs
IEEE 802.3ac – VLAN tagging extensions
Port-based VLAN (private port / private VLAN)
Tagged-based VLAN
VLAN Marking of Mirror Traffic
Quality of Service
8 priority queues per port
802.3x Flow Control
IP DSCP – Differentiated Services Code Point
IP precedence
IP protocol
Queuing Control – Strict and Weighted Round Robin
Source/Destination IP address
Source/Destination MAC address
Security
IEEE 802.1x Port Authentication
MAC-Based Port Authentication
Password Protection (encryption)
RADIUS Client
Secured Shell (SSHv2)
Secured Socket Layer (SSL)
RFC and MIB Support
Enterasys Entity MIB
Enterasys VLAN Authorization MIB
IEEE 802.1X MIB – Port Access
IEEE 802.3ad MIB – LAG MIB
RFC 826 – ARP and ARP Redirect
RFC 951, RFC 1542 – DHCP/BOOTP relay
RFC 1213 – RFC 1213-MIB/MIB II
RFC 1493 – BRIDGE-MIB
RFC 1643 – Ethernet-like MIB
RFC 2131, RFC 3046 – DHCP client//relay
RFC 2233 – IF-MIB
RFC 2271 – SNMP Framework MIB
RFC 2618 – RADIUS Authentication Client MIB
RFC 2620 – RADIUS Accounting Client MIB
RFC 2668 – Managed Object Definitions for 802.3 MAUs
RFC 2674 – P-BRIDGE-MIB
RFC 2674 – QBRIDGE-MIB VLAN Bridge MIB
RFC 2737 – Entity MIB (physical branch only)
RFC 2819 – RMON-MIB
RFC 2863 – IF-MIB
RFC 2933 – IGMP MIB
RFC 3289 – DiffServ MIB
RFC 3413 – SNMP Applications MIB
RFC 3414 – SNMP User-based Security Module (USM) MIB
RFC 3415 – View-based Access Control Model for SNMP
RFC 3580 – IEEE 802.1X Remote Authentication Dial In User Service (RADIUS) Usage Guidelines
RFC 3584 – SNMP Community MIB
RFC 3621 – Power over Ethernet MIB
Management
Alias Port Naming
Command Line Interface
Configuration Upload/Download
Editable Configuration File
FTP/TFTP client
Multi configuration File Support
NetSight Automated Security Manager
NetSight Console
NetSight Inventory Manager
NetSight Policy Manager
Node/Alias Table
RFC 854 – Telnet
RFC 1157 – SNMP
RFC 1901 – Community-based SNMPv2
RFC 2271 – SNMP Framework MIB
RFC 3413 – SNMPv3 Applications
RFC 3414 – User-based Security Model for SNMPv3
RFC 3415 – View-based Access Control Model for SNMP
RMON (Stats, History, Alarms, Events)
Simple Network Time Protocol (SNTP)
SSH
Syslog
Telnet
Text-based Configuration Upload/Download
Web-based Management
Webview via SSL Interface

  • HIMA PS1000/230010 982200080 high-performance power supply module
  • HIMA H7202 Distribution Fuse Board / Infeed Board
  • HIMA F60DIO24/1601 Safety-Related Controller
  • HIMA F60DO801 Safety-Related Controller
  • HIMA H7201 Line fuse board
  • HIMA HIMatrix ELOP II 892042336 Version V5.6 Build 1501.9810 IV1
  • HIMA HIMatrix SILworX 504110 895400001
  • HIMA HIMatrix SILworX 504111 895210001
  • HIMA OPC DA Server 892042400 Version 3.56.4
  • HIMA OPC Alarm & Event Server (892042420) Version 4.1.3
  • HIMA OPC Alarm & Event Server (892042420) Version 4.0.5
  • Phoenix QUINT-DIODE/12-24DC/2x20/1x40 2320157 Redundancy module
  • Phoenix QUINT-PS/1AC/24DC/40 2866789 Power supply
  • Moore SIY/PRG/4-20MA/10-42DC SIY PC Programmable Signal Isolator and Converter
  • Motorola 01-W3394F-03F Communication Interface Module
  • Motorola AP-4 256 MByte 01-W3839F-07A Communication Module
  • MOTOROLA MVME2432 01-W3394F-03C VME Processor Module
  • MOTOROLA PCE I 01-W3839F-07A VME Processor Module
  • Motorola HPR431 / SYS431 / SYS443 / MFT543 Component Assembly
  • Motorola AP-4 01-W3394F-03G Communication Interface Module
  • Emerson 01-W3878F-02D DeltaV M-Series I/O Module
  • ICS Triplex Trusted T8232 Power Pack Module
  • ALFA LAVAL AAL7000 OXYGEN ANALYSER V0.1
  • Alstom MPM123 Measurement and Protection Module
  • Honeywell 05701-A-0361 Engineering Card
  • Honeywell 05701-A-0351 PLC Module
  • Honeywell 5701 CONTROL SYSTEM
  • KONGSBERG MRU-E-JB1 Host machine
  • Woodward easYgen-3200-1/P1 8440-2049
  • Woodward easYPROTEC-1410-7 8441-1161 8441-1160
  • Woodward MFR300-71M/K45 8444-1111 8444-1112
  • Woodward MFR300-75M 8444-1107 8444-1108 8444-1109
  • Woodward MFR300-71M/K42 8444-1104
  • Woodward MFR300 75M/SU03, Transducer 8444-1093 8444-1094 8444-1095
  • Woodward MFR300-71M 8444-1091 8444-1092
  • Woodward MFR300-15M 8444-1090 8444-1089
  • Woodward MFR300-11M 8444-1071 8440-1089
  • Woodward MFR500-6M/WK0400 + DPC USB 8444-1070
  • Woodward MFR300-15M 8444-1064
  • Woodward SPM-D2-1040B/NYB 8440-2189
  • Woodward SPM-D2-1010B/NYB 8440-2177
  • Woodward SPM-D2-10B/PSY5-FU-D 8440-2170
  • Woodward SPM-D2-1040B/XN analog speed/voltage bias 8440-2190
  • Woodward MFR300-71M 8444-1063
  • SPM-D2-1010B/X analog speed/voltage bias 8440-2168
  • Woodward SPM-D2-1040B/X analog speed/voltage bias 8440-2171
  • Woodward SPM-D2-1010B/N wide range power supply 8440-2174
  • Woodward SPM-D2-1040B/N wide range power supply 8440-2175
  • Woodward SPM-D2-1010B /110VAC sensing 8440-2166
  • Woodward SPM-D2-1040B /400VAC sensing 8440-2164
  • Woodward DTSC-200A 8440-2297
  • Woodward DTSC-200-55B/K38 8440-2155
  • Woodward DTSC-200-51B 8440-1867 8440-1868
  • Woodward 8445-1049 8445-1048 Converter, 1x FO to CAN
  • Woodward easYlite-200 8446-1007 LED Lamp Expansion Module
  • Woodward IKD-OUT-16 16 DO Expansion Card 8440-2306
  • Woodward IKD-IN-16 16 DI Expansion Card 8440-2307
  • Woodward IKD1M 8 DI/8 DO Expansion Card 8440-2116
  • Woodward easYview-07-30 8446-1071
  • Woodward easYFLEX-3400XT-P2 (GAP) 8440-2217
  • Woodward easYFLEX-3400XT-P2 (GAP) 8440-2217
  • Woodward easY-I-3400XT-P1 8440-2293
  • Woodward easY-I-3500XT-P1 8440-2292
  • Woodward MSLC-2XT 8440-2298 Master Synchronizer and Load Control
  • Woodward DSLC-2XT 8440-2299 Digital Synchronizer and Load Control
  • Woodward: GC-3400XT-P1 8440-2267 Group Controller
  • Woodward: LS-612XT-P2 8440-2317
  • Woodward: CONTROL-LS-612XT-P1,8440-2222 Cabinet back mounting
  • Woodward: LS-522-1/P1 8440-2179
  • Woodward: LS-522-5/P1 8440-2151
  • Woodward: LS-512-1/P1 8440-2181
  • Woodward: LS-512-5/P1 8440-2153
  • Woodward: LS-521-1/P1 8440-2178
  • Woodward: CONTROL-LS-521-5/P1 8440-2150
  • Woodward: LS-511-1/P1 8440-2180 Circuit Breaker Control & Protection
  • Woodward: CONTROL-LS-511-5/P1 8440-2152 Circuit Breaker Control & Protection
  • Woodward easYgen-3500XT-P2-LT-RENTAL 8440-2291 Genset Control for
  • Woodward eeasYgen-3500XT-P2-RENTAL 8440-2290
  • Woodward easYgen-3200XT-RENTAL 8440-2285
  • easYgen-3500XT-P2-K58 8440-2318
  • easYgen-3500XT-P2-LT 8440-2089
  • Woodward easYgen-3500XT-P2 8440-2088 Genset Controller
  • Woodward: easYgen-3500XT-P1-LT 8440-2086
  • Woodward: easYgen-3500XT (P1) 8440-2085
  • Woodward: easYgen-3400XT (P2), Genset Controller 1A/5A 8440-2087
  • Woodward: easYgen-3400XT (P1) 8440-2084
  • Woodward 8440-2082 EasyGen 3200XT Genset Controller
  • Woodward: easYgen-3200XT (P1/LT) 8440-2083
  • Woodward: easYgen-3100XT 8440-2081
  • Woodward: easYgen-2500 (1A/P1) K33 8440-2096
  • Woodward easYgen-2500-5/P1-K33 Rental Version 8440-2029
  • Woodward easYgen-2500-1/P1 8440-1860
  • Woodward easYgen-2500-5/P1 8440-1884
  • Woodward easYgen-2300-1/P2 8440-2123 Controller
  • Woodward easYgen-2300-5/P2 8440-2058
  • Woodward 2300E – Ordinary Locations 8273-1017
  • Woodward Vertex Compressor Control 8200-1370
  • MicroNet Safety Module - Bulkhead Mount 8237-2492 Woodward
  • ProTech TPS - Bulkhead Mount Independent Relays 8237-2602
  • Woodward ProTech-GII - Bulkhead Mount Independent Relays 8237-2594
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX411/511010/STD Single and dual input analyzers
  • Woodward ProTech-SX - Panel Mount, HV/LV 8237-1242 8237-1243
  • Woodward SPC Servo Position Controller 8200-226 8200-227
  • Woodward Peak200 – Bulkhead Mount, LV 8200-1500
  • Woodward 505HT for Pelton Turbines 8200-1400, 8200-1401
  • Woodward 2301E-HT Hydro (Francis Turbines) P/N 8237-2046
  • Woodward 8273-1013 8273-1014 Digital Electronic Load Sharing
  • Control Panel 9907-2024 Woodward
  • ABB REF630 UBFNAAABBBAZANBBXB Feeder Protection and Device
  • ABB PPD513 A2A-11165 High-performance controller
  • UniOP CP10G-04 CP10G-04-0045 Interface Module
  • UNIOP MKDR-04-0021 Monochrome LCD (with Contrast Control)
  • UNIOP eTOP03-0046 Monochrome LCD (STN)
  • UNIOP MKDR-16-TA-0045 HMI TOUCH SCREEN
  • UNIOP Operator Interface Display MD02R-04-0042
  • UniOP Display Screen eTOP20C-0050 eTOP20C
  • UniOp eTOP05-0045 eTOP05. eTOP05P Operator Interface Touch Panel
  • UNIOP ETOP11-0050 HMI 5.6Color Operator Interface Touch Panel
  • UniOp eTOP306 Panel
  • UniOP eTOP308 ETOP308U301 HMI Panel
  • UniOP ePALM10-0061 Handheld Robot Trainer
  • UniOP CP01R-04 CP05R-04 and CP01F-02
  • Uniop MD02R-04 - MD02R-04-0045 Industrial PLC Workstation
  • Uniop Cp02r-04-0021 Operating Interface
  • UniOP ECT-16-0045 High-Performance Color Touchscreen HMI
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD04-0046 Compact Industrial Interface