• Application programs loaded into the controller (library functions, communication protocols).
To produce an application, it is necessary to use the Control Builder M tool. This tool is extremely versatile, having many useful functions in addition to system configuration.
Ethernet Address for PM8xx (Except PM891)
Each TP830 Baseplate is provided with a unique Ethernet address that provides every CPU with a hardware identity. This functionality takes the form of two identification addresses residing in the non-volatile memory of the TP830 Baseplate. The lowest address (a 12 character Hex code) is located on an adhesive label attached to the TP830 Baseplate. The remaining address is the lowest +1. See Figure 14 on page 53 for label location details. See software documentation for details on loading the software and using Ethernet address.
Ethernet Address for PM891
Each PM891 unit is provided with a unique Ethernet address that provides hardware identity to the unit. This functionality takes the form of two identification addresses residing in the non-volatile memory of PM891. The lowest address (a 12 character Hex code) is located on an adhesive label attached to the cover of PM891 unit. The remaining address is the lowest +1. See Figure 15 on page 55 for label location details of PM891. See software documentation for details on loading the software and using Ethernet address.
AC 800M Controller – Key Features
• Modularity, allowing for step-by-step expansion.
• Simple DIN-rail attachment/detachment procedures, using a unique slide and lock mechanism.
• Fast, simple troubleshooting procedures available via unit/channel LEDs.
• IP20 Class protection with no requirement for enclosures.
• Allows for the use of low-cost, sealed enclosures due to extremely low unit heat dissipation, even at an ambient temperature of 40 C (104 F) outside the enclosure.
• All units are fully EMC certified.
• Connection of up to 192 I/O signals, via Electrical ModuleBus, is available.
• Connection of up to 1344 I/O signals, via Optical ModuleBus, is available.
• Connection of S100 I/O is available.
• Connection of Satt I/O is available.
• Allows connecting a large number of I/Os, via PROFIBUS DP.
• Connection to FOUNDATION Fieldbus High Speed Ethernet (FF HSE).
• Connection to Modbus TCP. • Connection to IEC 61850.
• Connection to Advant Fieldbus 100.
• Connection to MOD5-to-MOD5.
• Connection to PROFINET IO.
• Connection to EtherNet/IP.
• Allows connecting custom protocols of a large amount of Serial communication RS-232C ports.
• Connection to MasterBus 300 Networks.
• Connection to INSUM via Gateway (Ethernet/LON).
• Connection to ABB Drives is available, over DriveBus and ModuleBus.
• Built-in battery backup of memory (except for PM891 that uses external battery backup only).
• External battery backup.
• CPU Redundancy (PM861/PM864/PM865/PM866/PM891).
• Redundant/sectioned CEX-Bus using a pair of BC810.
• Safety Integrity Level 2 certified controller using PM865/SM810/SM811.
• Safety Integrity Level 3 certified controller using PM865/SM811
• Support for hot swap of CEX-Bus units.
ABB AI610
ABB AI625
ABB AI835
ABB AO610
ABB AX411/50001
ABB BB510(DC5256)
ABB BRC300
ABB CI520V1
ABB CI610
ABB CI615
ABB CI626
ABB CI626V1
ABB CI627
ABB CI810B
ABB CP450-T-ETH
ABB CR-M4LS
ABB D-20-0-1102
ABB DAI03
ABB DAO01
ABB DCP02
ABB DCP10
ABB DDI01
ABB DDI03
ABB DDO01
ABB DDO02
ABB DI610
ABB DI620
ABB DI814
ABB DLM01