Honeywell CC-TCNT01 51308307-175 DATASHEET
Field Terminal Assembly (FTA)
New interfaces for the Honeywell Experion® PKS C300 controller
Weidmüller’s new interfaces and pre-assembled cables allow you to wire up
I/O cards from Honeywell’s C300 controller quickly and simply in the field.
The IOTAs (Input Output Terminal Assemblies) are designed using Weidmüller
PCB connectors and terminals. This design gives you the flexibility to connect directly
to the field cabling wire to wire or with a pre-assembled cable in combination
with Weidmuller‘s FTAs. In comparison to traditional wire-to-wire cabling, the new
Weidmuller FTAs and pre-cabling solution offer a highly efficient method of wiring
between I/O modules and the field.
Concise wiring in the electrical cabinet is possible because multicore cables are
used instead of individual wires. The cable harness can be delivered with double
or single connectors and even with unterminated ends.
The housing provides easy handling as well as a safe, firm connection to the IOTA.
It also allows you to use cables with large cross-sections.
Honeywell C300 - FTA C300
Input/output passive interface for digital cards
Passive interfaces (FTA) for connecting the Honeywell C300 digital IOTAs.
• Clearly labelled: Same connector and position on the FTA and on the IOTA
• LED and fuse protection per channel (optional)
• Possibility of feeding the IOTA from the FTA (fuse protected)
• Screw or tension clamp connection
Honeywell C300 - FTA C300 Input/output passive interface for analogue and digital cards
Passive interfaces (FTA) for connecting the Honeywell C300 analogue IOTAs.
• Same connector and position on the FTA and on the IOTA
• 2 units can also be used for digital IOTAs
• Disconnecting plugs and test points (2 mm in diameter) for voltage and current measurements
• M4 connection for the shielding
Honeywell C300 - FTA C300 Isolated output interface for digital cards
Passive interfaces (FTA) for connecting the Honeywell C300 analogue IOTAs.
• Clearly labelled: Same connector and position on the FTA and on the IOTA
• Input/output reinforced insulation (basic between contacts)
• Possibility of powering the IOTA from the FTA
• Screw or tension clamp connection
Honeywell C300 - Interconnection cables
Pre-built cables for connecting the CS300 cards to the Weidmüller interfaces. 2 ranges:
• Premium: With housing for the connector
• Basic: Without housing for the connector
PLC Front Adapter (FAD)
New Front Adapters for different PLC Cards.
Easy and fast field wiring on PLC I/O cards with new front adapters.
In comparison to traditional wire-to-wire cabling, the new front adapters (FAD), in combination with Weidmuller‘s interface range, offer a much more efficient method for field wiring on PLCs‘ I/O cards. Both can be connected to the standard active or passive interfaces range or to the relays or optos from Weidmüller‘s MICROSERIES. But the method with FADs is significantly easier and faster than with traditional wire-to-wire cabling. The pre-assembled cables are available in different lengths
Front adapter selection table for PLC (FAD) and interface modules.
Front adapters for PLCs (FAD-UNIV) are an easy solution for wiring I/O and supply signals from the PLC to the applications. Each signal is taken at a 1:1 relation to the RSF ribbon connector (digital signals) or SUB-D (analogue signals) using adequate (PAC) pre-assembled cables (table 1). In addition, we offer a wide range of interfaces (active and passive) for the cards of several major manufacturers that allow the use of our MICROSERIES opto modules and relays.
Selection table:
Choose your PLC card in steps 1 to 3. In step 4 you will find the PLC (FAD) front adapters, the pre-assembled cable (PAC) and the group of interfaces that can be used (in Table 1 or Table 2). In step 5, choose the most adequate interface for your application.
FAD - Front adapters for Siemens S7-300 and Rockwell Control-Logix
FAD - Front adapters for Siemens S7-300
Front adapters for Siemens S7-300 cards with 20 and 40 poles. • The voltage may be supplied directly to the front adapter and can be distributed in common or separately by byte (8 signals)
FAD - Front adapters
for Rockwell Control-logix
Front adapters for Rockwell Control-Logix cards with 20
and 36 poles.
• The voltage may be supplied directly to the front adapter
and can be distributed in common or separately by byte
(8 signals)
RSF PLC - Passive interface for digital signals
RSF PLC-Passive interface
for 1 wire digital signals
Compact interfaces for the transmission of 32 digital input/ output signals (RSF PLC)
• Signals can be grouped by byte (selected via jumpers)
• Option of switching by positive or negative signals (selected via jumpers)
• Optional status indicator (LED) showing the operating status and voltages
• Screw or tension clamp connection
MICRO-INTERFACE:
Solutions for PLC with relays and optos from the MICROSERIES family
The MICRO-PLC adapter is used to connect the MICROSERIES family relays and opto modules to the PLC or other controllers using pre-assembled cables. The adapter is formed using a 15 pole SUB-D connector or a 10 pole ribbon cable, and can be connected to a group of 8 MICROSERIES relays/opto modules, either with screw or tension clamp connection.
To help you to choose the right products for your application, Weidmüller offers selection tables in this catalogue that enable you to choose a set comprising pre-assembled cable + adapter + microrelay/optomodule, depending on the PLC card.