KONG -Y
NameDescriptionContent
Location:

DS200DCFBG1BLC General Electric Power Supply Board

From: | Author:kongjiang | Time :2025-04-22 | 205 Browse: | Share:

IMPORTANT SAFETY INSTRUCTIONS 

SAVE THESE INSTRUCTIONS 

 

This manual contains important instructions for models SG Series 225 & 300 that should be followed 

during installation and maintenance of the UPS and battery. 

 

 

GENERAL 

 - Move the UPS in an upright position in its original package to the final destination room. 

To lift the cabinets, use a forklift or lifting belts with spreader bars. - Check for sufficient floor and elevator loading capacity. - Check the integrity of the UPS equipment carefully. 

If you notice visible damage, do not install or start the UPS. 

Contact the nearest Service Center immediately. - WARNING! RISK OF ELECTRICAL SHOCK: 

Do not remove covers, there are no user serviceable parts inside. - After switching off takes 5 minutes for the DC capacitors to discharge because a lethally high voltage 

remains at the terminals of the electrolytic capacitors. - All maintenance and service work should be performed by qualified service personnel. 

The UPS contains its own energy source (battery). - The field-wiring outlets may be electrically live, even when the UPS is disconnected from the utility. - Dangerous voltages may be present during battery operation. - The battery must be disconnected during maintenance or service work. - This UPS contains potentially hazardous voltages. - Be aware that the inverter can restart automatically after the utility voltage is restored. 

 

 

INSTALLATION 

 - This UPS must be installed and connected only by trained personnel. - Verify accurately during Commissioning and Maintenance of the UPS, for the following: 

Damaged components, squeezed wires and cables, or not correctly inserted plugs. - After removing the sidewalls of the UPS, make sure that all earth connections when reassembling, are 

correctly reattached. - This UPS is intended for use in a controlled indoor environment free of conductive contaminants and 

protected against animals intrusion. - WARNING! HIGH EARTH LEAKAGE CURRENT: 

Earth connection is essential before connecting to AC input! - Switching OFF the unit does not isolate the UPS from the utility. - Do not install the UPS in an excessively humid environment or near water. - Avoid spilling liquids on or dropping any foreign object into the UPS. - The unit must be placed in a sufficiently ventilated area; the ambient temperature should not exceed 104°F (40°C). - Optimal battery life is obtained if the ambient temperature does not exceed 77°F (25°C). - It is important that air can move freely around and through the unit. Do not block the air vents. - Avoid locations in direct sunlight or near heat sources. 

STORAGE 

 - Store the UPS in a dry location; storage temperature must be within -13°F (-25°C) to 131°F (+55°C). - The optimal temperature for Battery storage is 68°F (20°C) to 77°F (25°C) and shall never exceed the range -4°F (-20°C) to 104°F (40°C). - If the unit is stored for a period exceeding 3 months, the battery must be recharged periodically (time 

depending on storage temperature). 

 

 

BATTERY 

 - The battery-voltage is dangerous for person’s safety. - When replacing the battery, use the same cells number, voltage (V), capacity (Ah). 

All the battery used, shall be of the same manufacturer and date of production. - Proper disposal or recycling of the battery is required. 

Refer to your local codes for disposal requirements. - Never dispose of battery in a fire: they may explode. - Do not open or mutilate battery: their contents (electrolyte) may be extremely toxic. 

If exposed to electrolyte, wash immediately with plenty of water. - Avoid charging in a sealed container. - Never short-circuit the batteries. 

When working with batteries, remove watches, rings or other metal objects, and only use insulated tools. - In case of air shipment, the cables +/- going to the battery fuses/terminals shall be disconnected and isolated. 

CONNECTION FOR OPTIONS 

The installation and cabling of the options must be performed by QUALIFIED SERVICE PERSONNEL ONLY. Make sure that the UPS installation is completely powered down. Refer to the “Safety prescriptions - Installation” described on Section 1.

Remote Signaling Box (RSB)   The optional Remote Signaling Box allows monitoring of the operation of the UPS, using the potential free contacts fitted on the “P4 - Customer Interface Board“ of the UPS. It can be used by simply putting the box on a desktop or on a wall or, removing the box, it can be surface mounted. The remote panel contains an internal buzzer and the following status indicators: • Mimic diagram With LEDs indicating the operation of Rectifier and Inverter, and the power source supplying the critical Load. • Alarm Indicating a critical situation on the UPS (LED light and audible alarm). • Stop Indicating the UPS is preparing to shut down in a short time. • Mute Push button, resets the buzzer. • Test Push button checks all the LEDs and the buzzer of the remote panel. The cable connecting the RSB to the UPS cabinet must be min. 16 wires / 0.25mm2. The plug B is included in the delivery of the option RSB (cable connecting UPS with RSB not included). Maximal allowable length: 985 ft (300 m). It must be wired at one end with a D - female plug- 25 pin (J2 – P4 Customer Interface Board).


  • Bently 2300/25 0002 Vibration Monitors
  • Bently 2300/20 0002 Vibration Monitors
  • ALSTOM VP327 020-23EU 75X-6025-29 Control mainboard VP32702
  • ABB NE802 3BSE080237R1 Industrial switch
  • ABB 3BSE080207R1 NE810 Industrial switch
  • MOTOROLA MVME2400 VME Processor Modules
  • ABB 3BHE021481R0001 intelligent current distr UNIT
  • MOTOROLA MVME2434 VME Processor Modules
  • METSO PDP606 CONTROLLER unit
  • WOODWARD PG-PL-29 Governor 8577-613
  • GE IS230TNRLH1B Combination module kit Mark VI
  • GE IS230TNAIH2C Combination module kit Mark VI
  • ABB 3ASC25H204 DAPU 100 Control board I/O
  • ABB 3BHE014070R0101 V PPC905AE101 CCB-2 COMPLETE
  • ABB PRC3BSE050198R1 PM866K01 Processor Unit
  • Kongsberg RAIV400 600370 Remote Analogue Input
  • ABB SPSED01 event sequence module
  • ABB HIEE300900R0001 PP C322 BE01 PSR-2 processor + fieldbus
  • ABB 3BHE003604R0102 UFC765AE102 circuit board
  • ABB ACU-01B 3HNA024871-001 Robot controller
  • ABB XVC770BE101 3BHE021083R0101 circuit board
  • ABB UAC383AE01 HIEE300890R0001 Module
  • ABB REF610C11LCNP FEEDER PROTECTION RELAY
  • ABB MT91 Operator Panel MT-91-ARC FP A
  • ABB XUD194 XUD194A 3BHC018137R0001 module base
  • ABB 5SHY4045L0001 3BHB018162 3BHE009681R0101 GVC750BE101
  • ABB G2000A5.7ST graphical operation panel (HMI)
  • ABB 3BHE017628R0002 PPD115A02 SG579989013
  • ABB Motor Protection and Control REM615 Product Guide
  • ABB PFTL101B 3BSE004185R1 2.0KN sensor
  • ABB PFCL201CE 50KN 3BSX802939-108 sensor
  • ABB 3BHE023784R2530 PPD113B01-25-111000 AC 800PEC
  • ABB 3BHE046836R0101 GF D563 A101 LCI Conv. Interface (LIN)
  • ABB PPD512A10-454000 3BHE040375R103E PPD512 丨AC800PEC
  • ABB PPD117A3011 3BHE030410R3011 excitation controller
  • ABB AC800M PM891 3BSE053240R1 Processor module
  • ABB PP882 3BSE069275R1 HMI operating touch screen
  • ABB HIEE205014R0001 UNC 4673A,V1 Analog Measuring Card
  • ABB 128057-204 ASPC ASSY, W/-004
  • ABB 3BHB006716R0277 SYN 5302a-Z,V277: Auto dual channel Syn
  • ABB PFSK 163 V3 3BSE016323R3 Module
  • ABB 3BUS208796-001 HKQCS PARTS ON LINE
  • ABB 2VAA008425R1 RMU610 Base for redundant cRBX01
  • ABB 3BSE018876R1 PFSK 151 DSP-Signal processing
  • Westinghouse 1C31129G03 1C31129G01, 1B30035H01 Ovation analog output module
  • Pacific scientific PC833-001-N-BA communication module
  • HONEYWELL 30733159-002 supplied by Honeywell
  • BENTLY 3500/94M 184826-01 VGA Display Monitor
  • BENTLY 1900/65A 172323-01General Purpose Equipment
  • Bently Nevada 9200-01-01-10-00 Speed Sensor
  • Bently Nevada 330104-00-05-10-02-00 Proximity detector
  • Bently Nevada 330901-05-32-05-02-00 3300 XL NSv proximity sensor
  • Bently Nevada ASSY78462-01U I/O module recording terminal
  • 330901-00-90-05-02-00 Bently Nevada3300 NSv Proximity Probes
  • 330180-X1-CN Bently Nevada Proximity sensor
  • Bently Nevada 3500/92 136188-01 RS232 communication gateway module
  • General Electric Multilin345-E-P1-G1-L-E-E-N-Sn-D-N Transformer Protection
  • ALSTOM MV507A2D1A frequency driver Alspa MV500
  • Carrier CEPL130201-02 6400 General Purpose HVAC Comfort Controller
  • Carrier Transicold dual-view temperature display 76-50202-01/ 76-60876-01
  • Carrier CEPL131258-01-R HVAC system touch screen
  • Carrier Ces0110074-01 circuit control board
  • Carrier handheld controller CEPL130435-01 HK50AA033
  • Carrier-A12-00703-04 3922M1042473 stepper valve module
  • CARRIER 00PSG000469000A CEPL 130602-02-R CEBD 430602-07-RA
  • Hirschmann MM20-M4M4T1T1SBH Industrial Ethernet module
  • IC752SPL011 GE control panel
  • GE ALSTOM IR139-1丨063022350丨80801419丨B0037299control card
  • ALSTOM UT150-1 control module
  • ALSTOM AL132丨AL132A Control Card
  • ABB 2CTB802342R0000 surge protector
  • ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • Tektronix TDP0500 high pressure differential probe
  • Carrier CEPL130403-02-R Microprocessor Board CEBD430403-11-RC 32GB500382EE
  • BENTLY 106M1079-01-Y Power Module Original
  • ABB system module DLM02 original DO610,DO620
  • 1394-SJT22-A servo driver Allen-Bradley servo equipment
  • MOTOROLA SGLF4136FA PLC control system
  • B&R ECPE84-1B Modulus Input Module Quality Service
  • Foxboro FBM213 communication module supply
  • S-093H 3BHB030478R0309 ABB high voltage frequency conversion rack
  • ABB S-123H 3BHB030479R0512 rack
  • ABB 3BHL000406P0103 VFW 30/265Processor unit
  • ALSTOM V4561983-0100 EPIC II ESP controller
  • MOOG G761-3004B5 H38JOGM5VPH Servovalve
  • 3500 BentlyNevada 3500/05-02-01-00-00-00 System rack
  • 3500/05-01-02-00-00-01 Bently Nevada 3500/05 System Rack
  • 3500/05-01-01-00-00-00 BentlyNevada System Rack
  • BentlyNevada 3500/05-02-01-01 System Rack
  • 3500/05-01-01-01-00-00 Bently Nevada 3500/05 System frame
  • BentlyNevada3500/95 System Integrated PC Display
  • 3500/93 Bently Nevada System Display
  • General electric IS215GBIAH1A auxiliary Genius bus interface module
  • ABB FF HSE Communication Module - Spare Parts
  • Alstom Villeurbanne N895600512D - M1000417012 ECPU1
  • ALSTOM MMLB01 - TR11/Module Relay Tropic Alstom Used
  • ALSTOM MVAAM11B1CJ5516A - Protection Relay
  • Alstom N895605527E - EHICOM Mod GS 2S.517 1000423532
  • GE FANUC/ALSTOM AL122A - Martek Power CD101320 C145
  • ALSTOM VAG21ZG8002ADCH - INSTANTANEOUS VOLTAGE RELAY
  • Alstom Micom C264 DS - Agile Bay Controller C264MB1M691002320100000C000N10
  • ALSTOM GECOSTAT MC15-M2 - Manual Control Unit
  • Alstom 45533-014-00 - Shutdown Small Gear New
  • ALSTOM PIB101C-3BD91299-B - CONVERTEAM PCB Module
  • ALSTOM Microverter D 3.4/500, 029.130 004 - NEU
  • GE Convertam Alstom 3BEB0190 C - PIB 310
  • ALSTOM PIB100G,3BEE026 - Board
  • Converteam PIB201A / Alstom PIB 201A /3BEC0067 - PCB
  • CELEC ALSPA GD3000E - 20X4249A4 Controller Alstom
  • Alstom Brown Boveri - D 421631P0001 Locking Ring
  • Alstom Villeurbanne N895603522A - EVIN16 2 M1 GS Board EVIN16
  • ALSTOM Micom P139 - PTB 04 ATEX3044 P1393604544AW00E01
  • ALSTOM VAA23ZG750BA - AUXILIARY RELAY
  • Alstom Power HTGD333350P0049 - Tool Key Segment
  • ALSTOM Alspa MV530A4C1A SE43401500
  • ALSTOM EP3-E-4-EN - EPIC III Control Module
  • ALSTOM PCB - 029.218206 FS02 BZB 029.228500/04 053023008 / FAST SHIP DHL OR FEDEX
  • ALSTOM Zusatz Relay - Vaa23zg8507f (M) 110-250V AC / DC
  • Alstom 29069608 - PC Board
  • Alstom vagm22af171g - Instantaneous Under Voltage Relay
  • ALSTOM MVC3002-4001 - MV3000 DELTA I/O PANEL REV 0001
  • Alstom ske11bf8003bch - Carried Synchronising Relay
  • Alstom ALSPA C80-35 - Power Supply CE693PWR330F
  • ALSTOM PIB 504 - FIBER OPTIC PIB MODULE PIB504 3BEE0088
  • Alstom vajh13yf1001aba - Automatic Trip Relay 220-250 V
  • ALSTOM D-984 0584 - 2/4 Flame & Fault Alarm Board
  • ALSTOM 31V6900/10 - GD Delta Cooling System Build Rev 0015
  • ALSTOM JOYSTICK - Controller Station W/ Wall Mount Bracket For Marine DP System