information on analog input.
If you have to modify this setting don't forget : Any correction on the big diameter PID has to be done with big
diameter information present on analog input. And, any correction on the small diameter PID has to be done with small
diameter information present on the analog input.
In general : The P term is practically in proportion with diameter, rather less.
The D term can be decreased in higher proportion than the diameter
The I term is decrease in lower proportion than the diameter, can some time stays constant
H MEMORY CARD
Using memory card HMCS2000-CRD2 as memory programme back-up or quick programme change.
The front face of the controller offers a slot in which can be plugged the memory card.
The memory card can contents 2 full HMCS2000-ECA programmes. When operating load / download the 2 programmes
are identified on display by Part A and Part B.
For downloading from the HMCS2000-ECA unit to the card you need either the PRG or the DP. Loading the
programme from the card to the HMCS2000-ECA unit is made with same tools.
IMPORTANT : For automatic loading without the use of PRG, proceed as follow :
● With HMCS2000-ECA switched OFF, plug in the memory card
● Switch ON the HMCS2000-ECA (apply the 24 VDC power supply)
● The part A of the memory card will automatically be loaded in the HMCS2000-ECA
Of course it’s admitted that the memory card has previously been loaded with a correct programme !.
Loading and downloading from HMCS2000-ECA to the memory card HMCS2000-CRD-2 :
Enter in the programme until you get
Press OK to enter in the MEMORY CARD menu
Follow scrupulously the display indication.
Press ESC many times to turn back to default display
I
FACTORY SET
2. MEMORY CARD
2. LANGUAGE
on screen
WARNING in FACTORY SET step programme. Soon as you see FACTORY SET appearing on top line display all
data will be lost if you press OK. There is no advising on display. Then before pressing OK be sure you want to return
to factory setting.
This function is used in the case where – for some unknown reason – you prefer to restart your programmation.
If by mistake you are on the FACTORY SET step programme press ESC to leave this position.