KONG -Y
NameDescriptionContent
Location:

Hirschmann MM20-M4M49999TAHH Media converter

From: | Author:kongjiang | Time :2025-04-15 | 81 Browse: | Share:

Important information Note: Read these instructions carefully, and familiarize yourself with the device before trying to install, operate, or maintain it. The following notes may appear throughout this documentation or on the device. These notes warn of potential hazards or call attention to information that clarifies or simplifies a procedure. 

 Symbol explanation This is a general warning symbol. This symbol alerts you to potential personal injury hazards. Observe all safety notes that follow this symbol to avoid possible injury or death. If this symbol is displayed in addition to a safety instruction of the type “Danger” or “Warning”, it means that there is a danger of electric shock and failure to observe the instructions will inevitably result in injury. This symbol indicates the danger of hot surfaces on the device. In connection with safety instructions, non-observance of the instructions will inevitably result in injuries.

Safety instructions

UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices.Failure to follow these instructions can result in death, serious injury, or equipment damage.

General safety instructions You operate this device with electricity. Improper usage of the device entails the risk of physical injury or significant property damage. The proper and safe operation of this device depends on proper handling during transportation, proper storage and installation, and careful operation and maintenance procedures. 

 Before connecting any cable, read this document, and the safety instructions and warnings. 

 Operate the device with undamaged components exclusively. 

 The device is free of any service components. In case of a damaged or malfunctioning device, turn off the supply voltage and return the device to Hirschmann for inspection. 

 Certified usage 

 Use the product only for the application cases described in the Hirschmann product information, including this manual. 

 Operate the product only according to the technical specifications. See “Technical data” on page 44. 

 Connect to the product only components suitable for the requirements of the specific application case.

 Installation site requirements 

 If you connect the device to a power supply that does NOT meet the requirements for Limited Power Source, NEC Class 2 or PS2 according to IEC/EN 62368-1 and is NOT limited to 100 W output power, the device must be installed in either a switch cabinet or other fire enclosure. The fire enclosure can be made of metal or plastic with fire-protection properties of at least V-1 according to IEC 60695-11-10. Bottom openings of the fire enclosure must NOT exceed 2 mm in diameter. 

 Only for device variants featuring supply voltage with characteristic value M9: See “Device name and product code” on page 17. Install this device only in a switch cabinet or in an operating site with restricted access, to which maintenance staff have exclusive access. 

 Strain relief Note: If the strain relief is insufficient, there is a risk of torsion, contact problems and creeping interruptions. 

 Relieve the connection points of cables and lines from mechanical stress. 

 Design strain relieves in such a way that they prevent any mechanical damage to cables, wires or conductors caused by external influences or their own weight. 

 To prevent damage to device connections, connectors and cables, follow the instructions for proper installation in accordance with DIN VDE 0100-520:2013-06, sections 522.6, 522.7 and 522.13. 

 Device casing Only technicians authorized by the manufacturer are permitted to open the casing. 

 Never insert pointed objects (narrow screwdrivers, wires, etc.) into the device or into the connection terminals for electric conductors. Do not touch the connection terminals. 

 Keep the ventilation slits free to ensure good air circulation. 

 Mount the device in the vertical position. 

 At ambient air temperatures > +140 °F (+60 °C): The surfaces of the device housing may become hot. Avoid touching the device while it is operating. 

 Qualification requirements for personnel 

 Only allow qualified personnel to work on the device.

Qualified personnel have the following characteristics: 

 Qualified personnel are properly trained. Training as well as practical knowledge and experience make up their qualifications. This is the prerequisite for grounding and labeling circuits, devices, and systems in accordance with current standards in safety technology. 

 Qualified personnel are aware of the dangers that exist in their work. 

 Qualified personnel are familiar with appropriate measures against these hazards in order to reduce the risk for themselves and others. 

 Qualified personnel receive training on a regular basis. 

 National and international safety regulations Verify that the electrical installation meets local or nationally applicable safety regulations. 

  • Hirschmann MM20-M4M4T1T1SBH Industrial Ethernet module
  • IC752SPL011 GE control panel
  • GE ALSTOM IR139-1丨063022350丨80801419丨B0037299control card
  • ALSTOM UT150-1 control module
  • ALSTOM AL132丨AL132A Control Card
  • ABB 2CTB802342R0000 surge protector
  • ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • Tektronix TDP0500 high pressure differential probe
  • Carrier CEPL130403-02-R Microprocessor Board CEBD430403-11-RC 32GB500382EE
  • BENTLY 106M1079-01-Y Power Module Original
  • ABB system module DLM02 original DO610,DO620
  • 1394-SJT22-A servo driver Allen-Bradley servo equipment
  • MOTOROLA SGLF4136FA PLC control system
  • B&R ECPE84-1B Modulus Input Module Quality Service
  • Foxboro FBM213 communication module supply
  • S-093H 3BHB030478R0309 ABB high voltage frequency conversion rack
  • ABB S-123H 3BHB030479R0512 rack
  • ABB 3BHL000406P0103 VFW 30/265Processor unit
  • ALSTOM V4561983-0100 EPIC II ESP controller
  • MOOG G761-3004B5 H38JOGM5VPH Servovalve
  • 3500 BentlyNevada 3500/05-02-01-00-00-00 System rack
  • 3500/05-01-02-00-00-01 Bently Nevada 3500/05 System Rack
  • 3500/05-01-01-00-00-00 BentlyNevada System Rack
  • BentlyNevada 3500/05-02-01-01 System Rack
  • 3500/05-01-01-01-00-00 Bently Nevada 3500/05 System frame
  • BentlyNevada3500/95 System Integrated PC Display
  • 3500/93 Bently Nevada System Display
  • General electric IS215GBIAH1A auxiliary Genius bus interface module
  • MOOG D137-004-006 Servo valve controller
  • MOOG D137-004-005 Industrial controller
  • MOOG D137-004-004 Motion controller
  • D137-004-003 MOOG RDISP 22 operation panel
  • MOOG D138-002-003
  • MC 600 SERIES D138-002-002 MACHINE CONTROLLER MOOG
  • MOOG D138-002-001
  • MOOG B95914-001 Plate and fittings
  • D138-003-010 - Visualization HMI run time license (MACS HMI) for 10 machines
  • MOOG MACS HMI 1 - D138-003-001
  • MOOG D137-002-001 control module
  • MOOG QEBUS-CAN - D137-001-010
  • MOOG QAIO 16/4-V - D137-001-007
  • MOTOROLA MVME7100 - High-Speed Embedded Controller, VME
  • Motorola MVME2432 - VME Embedded Controller
  • Motorola СPU3640FLN3524A - Embedded Processor Module
  • MOTOROLA MVME187-24B01-W36908 - High-Performance
  • Motorola MVME162P-344 - VME Controller, 68040 Processor, Industrial Automation
  • Motorola FLN4234A - Embedded System Controller
  • Motorola MVME2604712 I/O-VME board
  • MOTOROLA MVME-51005E-0163-VME Embedded Controller
  • MOTOROLA MVME162PA-344SE - VME Controller
  • MOTOROLA MVME6100-0161 - High-Performance VME Board
  • MOTOROLA MVME55006E-0161R - Enhanced Performance VME Controller
  • MOTOROLA MVME162-523A - VME Controller
  • Motorola PCB MVME 2434 SBC PMC-HS/GE FANUC PMC661J card
  • Motorola MVME55006E-0163-VME processor board
  • MOTOROLA VME162PA344SE - Enhanced VME Controller
  • MOTOROLA MVME5500 - High-Performance VME Controller
  • MOTOROLA MVME147-023 - Legacy VME Board, Embedded Controller, Industrial Automation
  • MOTOROLA VME162PA-252SE - VME Board, Legacy System Controller, Industrial Automation
  • MOTOROLA MVME6100+5264- VME Board with Memory Expansionerformance Industrial Controller
  • MOTOROLA MVME2305-900 - VME Embedded Controller
  • Motorola MVME3100-1152-Enhanced VME Controller
  • Motorola MVME147-012-Traditional VME Board
  • Motorola MVME147-013-Traditional VME Board
  • MOTOROLA MVME-5101-0131-VME Embedded Controller
  • MOTOROLA MVME5101-0131 - VME Embedded Controller
  • MOTOROLA MVME167P-24SE - VME Controller
  • Motorola MVME7100-0171 - High-Speed Embedded Controller
  • MOTOROLA MVME3100 - High-Performance VME Controller
  • MOTOROLA MVME147-010 - Legacy VME Board,
  • MOTOROLA MVME55006E-0163R - Enhanced Performance VME Controller, Industrial Control Systems
  • MOTOROLA MVME5110-2261 - Enhanced VME Controller
  • MOTOROLA MVME2305-900 - VME Embedded Controller
  • MOTOROLA MVME5100-0163 High-Performance VME Embedded Controller
  • MOTOROLA MVME-147A0-60063-1 - Legacy VME Board, Industrial Automation Applications, Embedded Systems
  • MOTOROLA IPMC761-001 - PMC Carrier Board
  • MOTOROLA MVME6100-163 - Enhanced VME Controller
  • MOTOROLA MVME162-213 - Embedded Controller
  • MOTOROLA MVME162-022A - Embedded VME Board
  • MOTOROLA MVME61006E-0163R+P.N5264 - VME Processor Board
  • MOTOROLA MVME61006E-0161R+P.N5264 - Enhanced VME Processor Board, 1.3 GHz, Memory Card Supported
  • MOTOROLA MVME6100 (01-W3878F14B) - VME Embedded Controller
  • MOTOROLA APPLIED0100-01396 - Applied Computing Board
  • MOTOROLA MVME162PA-344 - VME Controller
  • MOTOROLA MVME2100 - Low-Cost Embedded VME Board
  • Motorola MVME5100-VME embedded controller, high-speed data processing.
  • MOTOROLA MVME162-202 - Embedded Controller, VME
  • MOTOROLA MVME7100-0173-2G - Embedded Controller
  • TRICONEX 2301 - Digital Output Module, High-Speed, Industrial Systems
  • TRICONEX 2351 Analog Input Module, High-Precision
  • TRICONEX 2401-Digital Input Module, Compact
  • TRICONEX 2101 Main Processor Module, Modular, High-Performance
  • TRICONEX 2381 - Digital Input Module, Compact Design, High-Precision
  • TRICONEX 9566-810 Power Supply Module, Modular
  • TRICONEX 8312 - Communication Module
  • TRICONEX FTA-544 Termination Assembly Modular
  • TRICONEX 3604E - TMR Digital Output Module, High-Precision
  • TRICONEX 9566-810F Power Supply Module, Compact
  • TRICONEX 3451 Analog Input Module, Compact
  • TRICONEX 3211S-analog input module
  • TRICONEX DI3301S2 Digital Input Module
  • TRICONEX 3481S2 Analog Output Module, Redundant
  • TRICONEX 3511 Main Processor Module, Modular
  • TRICONEX 3101 Main Processor Module
  • TRICONEX 8111 Communication Module
  • TRICONEX 4210 Analog Input Module
  • TRICONEX 4211 Analog Input Module
  • TRICONEX CIM3211S2 Communication Interface Module
  • TRICONEX MA2211-100S2 Communication Module, Redundant
  • TRICONEX MA2211-100 Communication Module, Compact
  • TRICONEX AO3481 Analog Output Module
  • TRICONEX 3501TN2 - Main Processor Module
  • TRICONEX 3623T Digital Output Module High-Precision
  • TRICONEX 3009 Main Processor Module, High-Speed
  • TRICONEX 3009X - Main Processor Module
  • TRICONEX 8310 Communication Module
  • TRICONEX 3008 - Main Processor Module, Modular, High-Speed
  • TRICONEX 3301-Digital Input Module
  • TRICONEX 3700A-Communication module, high performance
  • TRICONEX 3504E - Main Processor Module
  • TRICONEX 3503E Main Processor Module
  • TRICONEX 3481S Analog Output Module
  • TRICONEX 3351 Analog Input Module
  • TRICONEX 3401 Analog Input Module
  • TRICONEX RXM4201 Communication Module
  • TRICONEX RXM4200-3 - Communication Module
  • TRICONEX 3624 Digital Output Module
  • TRICONEX 3704E - Digital Input Module