Description and operating instructions
Safety instructions
Certified use
Please observe the following points:
Z warning!
The equipment can only be used for the purpose and technical description described in the catalogue, and only with external equipment and parts recommended or approved by Hirschmann. The product can be handled correctly and safely only under the following conditions: it is transported, stored, installed and assembled correctly. In addition, care must be taken in operation and maintenance. The power supply voltage is supplied by NEC-class power supply through the mouse switch module.
For Ethernet power supply module: connect a NEC-only power supply. Use+60/75 c or+75 c copper wire only. Only zero potential supply voltage is used. Otherwise, ground the power supply through GND. The positive grounding of the power supply voltage is not allowed.
Shielding Ground Note: The shielding ground of the connectable twisted pairs lines is connected to the front panel as a conductor.
□ Beware of possible short circuits when connecting a cable section with conductive shielding braiding.
Casing z Warning! Only technicians authorized by Hirschmann are permitted to open the casing.
□ Make sure that the electrical installation meets local or nationally applicable safety regulations.
z Warning! Never insert pointed objects (thin screwdrivers, wires, etc.) into the inside of the subrack! This especially applies to the area behind the socket connectors. Failure to observe this point may result in injuries caused by electric shocks.
General Safety Instructions □ Particular attention is to be paid to all warnings and items of information relating to safety. □ Peripheral equipment must be suitable for the location in which it is used.
Warning! Any work that may have to be performed on the electrical installation should be performed by fully qualified technicians only
Note: LED or LASER components in compliance with IEC 60825-1: CLASS 1 LASER PRODUCT for Cat. No. having the following fiber optic modules (identified by module code) incorporated: S2, S4, E2, L2, G2, Z6, O7. CLASS 1 LED PRODUCT for Cat. No. having the following fiber optic modules (identified by module code) incorporated: M2, M3, M4, F4. Refer to the product code description in chapter 7.
ESD guidelines The modules are equipped with electrostatically sensitive components. These can be destroyed, or their life cycles reduced, by the effects of an electrical field or by a charge equalization if the connections are touched. You will find information about electrostatically endangered assemblies in DIN EN 61340-5-1 (2007-08) and DIN EN 61340-5-2 (2007-08).
The devices comply with the regulations contained in the following European directive(s): 2014/30/EU (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility. 2011/65/EU (RoHS) and 2015/863/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
2014/34/EU (ATEX) Directive of the European Parliament and of the Council on the harmonisation of the laws of the Member States relating to equipment and
protective systems intended for use in potentially explosive atmospheres. Note: The ATEX Directive applies exclusively to the device variants labeled with an ATEX certificate number: DEKRA 13ATEX0019 X In accordance with the above named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen You find the EU declaration of conformity as PDF file for downloading on the Internet at: https://www.doc.hirschmann.com/certificates.ht ml The product can be used in living areas (living area, place of business, small business) and in industrial areas.
– Interference immunity: EN 61000-6-2
– Emitted interference: EN 55032 Class A
Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures. The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values.
UKCA marking The labeled devices comply with the following UK regulations: S.I. 2012 No. 3032 Restriction of the Use of Certain Hazardous Substances in Electrical and Electronical Equipment Regulations S.I. 2016 No. 1091 Electromagnetic Compatibility Regulations S.I. 2016 No. 1107 Equipment and Protective Systems Intended for use in Potentially Explosive Atmospheres Regulations Note: This UK regulation applies exclusively to the device variants labeled with a UKEX certificate number: DEKRA 21UKEX0068 X The UKCA conformity declaration will be available to the relevant authorities at the following address: Belden UK Ltd. 1 The Technology Centre, Station Road Framlingham, IP13 9EZ, United Kingdom You find the UKCA conformity declaration as PDF file for downloading on the Internet at: https://www.doc.hirschmann.com/certificates.ht ml The product can be used in living areas (living area, place of business, small business) and in industrial areas.
– Interference immunity: EN 61000-6-2
– Emitted interference: EN 55032 Class A
Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures. The assembly guidelines provided in these instructions must be strictly
FCC note Supplier’s Declaration of Conformity 47 CFR § 2.1077 Compliance Information MICE Media Modules MM2..., MM3..., MM4...; MICE expansion module MB20 U.S. Contact Information Belden – St. Louis 1 N. Brentwood Blvd. 15th Floor St. Louis, Missouri 63105, United States Phone: 314.854.8000 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment. The device creates and uses high frequencies and can radiate same, and if it is not installed and used in accordance with this operating manual, it can cause radio transmission interference. The use of this device in a living area can also cause interference, and in this case the user is obliged to cover the costs of removing the interference.
Recycling note: After its use, this product has to be processed as electronic scrap and disposed of according to the prevailing waste disposal regulations of your community / district / country / state. in compliance with the actual measured temperature values. Use in Hazardous Locations – Relev。
North America This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D hazardous locations
– only for devices labeled accordingly
– OR non-hazardous locations. z Warning! EXPLOSION HAZARD
– Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous. z Warning! EXPLOSION HAZARD
– Substitution of any components may impair suitability for Class I, Division 2. z Avertissement! RISQUE D’EXPLOSION – Ne pas débrancher tant que le circuit est sous tension à moins que l'emplacement soit connu pour ne contenir aucune concentration de gaz inflammable. z Avertissement! RISQUE D’EXPLOSION
– La substitution de tout composant peut rendre ce matériel incompatible pour une utilisation en classe I, division 2
For devices installed in explosive gas atmospheres according to ATEX directive 2014/34/EU In Ex zone 2, only devices with a corresponding label may be operated. When operating the devices and modules in Ex zone 2, the following applies: MB20 and MM20, MM21, MM30, MM31 Series:
II 3 G Ex ec IIC T4 Gc DEKRA 13ATEX0019 X Temperature Code T4 for nomenclature parameter S or T or E. Ta: 0 °C ... +60 °C for nomenclature parameter S. Ta: -40 °C ... +70 °C for nomenclature parameter T or E. Restriction to MM30, MM31 Series: Ta: -40 °C ... +60 °C for nomenclature parameter T or E.
Special Conditions for safe use: □ Install the modules in a suitable enclosure in accordance with EN IEC 60079-0, providing a degree of protection of at least IP54 according to EN 60529, taking into account the environmental conditions under which the equipment will be used. □ When the temperature under rated conditions exceeds +70 °C at the cable or conduit entry point, or +80 °C at the branching point of the conductors, the temperature specification of the selected cable shall be in compliance with the actual measured temperature values.
For devices installed in explosive gas atmospheres according to UK regulation S.I. 2016 No. 1107 (as amended by S.I. 2019 No. 696) - Schedule 3A, Part 6 In Ex zone 2, only devices with a corresponding label may be operated. When operating the devices and modules in Ex zone 2, the following applies: MB20 and MM20, MM21, MM30, MM31 Series:
DEKRA 21UKEX0068 X Temperature code T4 for nomenclature parameter S or T or E. Ta: 0 °C ... +60 °C for nomenclature parameter S Ta: -40 °C ... +70 °C for nomenclature parameter T or E. Restriction to MM30, MM31 Series: Ta: -40 °C ... +60 °C for nomenclature parameter T or E. Special Conditions for safe use:
□ Install the modules in a suitable enclosure in accordance with EN IEC 60079-0, providing a degree of protection of at least IP54 according to EN 60529, taking into account the environmental conditions under which the equipment will be used. □ When the temperature under rated conditions exceeds +70 °C at the cable or conduit entry point, or +80 °C at the branching point of the conductors, the temperature.
specification of the selected cable shall be in compliance with the actual measured temperature values. For devices installed in explosive gas atmospheres under IECEx conditions Only intended for devices labeled accordingly. Marking: MB20 and MM20, MM21, MM30, MM31 Series: Ex ec IIC T4 Gc IECEx DEK 14.0078 X Temperature Code T4 for nomenclature parameter S or T or E. Ta: 0 °C ... +60 °C for nomenclature parameter S. Ta: -40 °C ... +70 °C for nomenclature parameter T or E. Restriction to MM30, MM31 Series:https://itadcs.com/ Ta: -40 °C ... +60 °C for nomenclature parameter T or E. Special Conditions for safe use:
□ Install the modules in a suitable enclosure in accordance with IEC 60079-0, providing a degree of protection of at least IP54 according to IEC 60529, taking into account the environmental conditions under which the equipment will be used.
□ When the temperature under rated conditions exceeds +70 °C at the cable or conduit entry point, or +80 °C at the branching point of the conductors, the temperature specification of the selected cable shall be in compliance with the actual measured temperature values.
□ The equipment shall only be used in an area of not more than a pollution degree 2, as defined in IEC 60664-1. You will find further information on the basic device in the installation guide MS20/30.