KONG -Y
NameDescriptionContent
Location:

MVI56E-MNETCR ControlLogix Platform Modbus TCP/IP Multi Client Enhanced Communications Module for Remote Chassis

From: | Author:kongjiang | Time :2025-03-05 | 73 Browse: | Share:

MVI56E-MNETCR ControlLogix Platform Modbus TCP/IP Multi-Client Enhanced Communication Module для удаленных корпусов

MVI56E-MNETCR-PROSOFT

The module uses a rechargeable Lithium Vanadium Pentoxide battery to back up the real-time clock and CMOS settings. The battery itself should last for the life of the module. However, if left in an unpowered state for 14 to 21 days, the battery may become fully discharged and require recharging by being placed in a powered-up ControlLogix chassis. The time required to fully recharge the battery may be as long as 24 hours. Once it is fully charged, the battery provides backup power for the CMOS setup and the real-time clock for approximately 21 days. Before you remove a module from its power source, ensure that the battery within the module is fully charged (the BATT LED on the front of the module goes OFF when the battery is fully charged). If the battery is allowed to become fully discharged, the module will revert to the default BIOS and clock settings. 

Important Safety Information - MVI56E Modules

ATEX Warnings and Conditions of Safe Usage Power, Input, and Output (I/O) wiring must be in accordance with the authority having jurisdiction A Warning - Explosion Hazard - When in hazardous locations, turn off power before replacing or wiring modules.   B Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous.   C These products are intended to be mounted in an IP54 enclosure. The devices shall provide external means to prevent the rated voltage being exceeded by transient disturbances of more than 40%. This device must be used only with ATEX certified backplanes.   D DO NOT OPEN WHEN ENERGIZED. Electrical Ratings Backplane Current Load: 800 mA @ 5 Vdc; 3 mA @ 24 Vdc   Operating Temperature: 0°C to 60°C (32°F to 140°F)   Storage Temperature: -40°C to 85°C (-40°F to 185°F)   Shock: 30 g operational; 50 g non-operational; Vibration: 5 g from 10 Hz to 150 Hz   Relative Humidity 5% to 95% (without condensation) All phase conductor sizes must be at least 1.3 mm (squared) and all earth ground conductors must be at least 4mm (squared).

To get the most benefit from this User Manual, you should have the following 

skills: Rockwell Automation® RSLogix™ software: launch the program, configure ladder logic, and transfer the ladder logic to the processor  Microsoft Windows: install and launch programs, execute menu commands, navigate dialog boxes, and enter data Hardware installation and wiring: install the module, and safely connect Modbus TCP/IP and ControlLogix devices to a power source and to the MVI56E-MNETCR module’s application port(s) 

What's New? 

MVI56E products are backward compatible with existing MVI56 products, ladder logic, and module configuration files already in use. Easily swap and upgrade products while benefiting from an array of new features designed to improve interoperability and enhance ease of use. Web Server: The built-in web server and web page allow access to manuals and other tools previously provided only on a product CD-ROM or from the 

ProSoft Technology® web site. ProSoft Configuration Builder (PCB): New Windows software for diagnostics, connecting via the module's Ethernet port or CIPconnect®, to upload/download module configuration information and access troubleshooting features and functions. ProSoft Discovery Service (PDS): Utility software to find and display a list of MVI56E modules on the network and to temporarily change an IP address to connect with a module's web page. CIPconnect-enabled: Allows PC-to-module configuration and diagnostics from the Ethernet network through a ControlLogix 1756-ENBT EtherNet/IP™ module. Personality Module: An industrial compact flash memory card storing the module’s complete configuration and Ethernet settings, allowing quick and easy replacement. LED Scrolling Diagnostic Display: 4-character, alphanumeric display, providing standard English messages for status and alarm data, and for processor and network communication status. 

System Requirements

The MVI56E-MNETCR module requires the following minimum hardware and software components: Rockwell Automation ControlLogix® processor (firmware version 10 or higher), with compatible power supply, and one free slot in the rack for the MVI56E-MNETCR module. The module requires 800 mA of available 5 Vdc power Rockwell Automation RSLogix 5000 programming software   o Version 16 or higher required for Add-On Instruction o Version 15 or lower must use Sample Ladder, available from www.prosoft-technology.com Rockwell Automation RSLinx® communication software version 2.51 or higher ProSoft Configuration Builder (PCB) (included) ProSoft Discovery Service (PDS) (included in PCB) Pentium® II 450 MHz minimum. Pentium III 733 MHz (or better) recommended   Supported operating systems: o Microsoft Windows® Vista o Microsoft Windows XP Professional with Service Pack 1 or 2   o Microsoft Windows 2000 Professional with Service Pack 1, 2, or 3 o Microsoft Windows Server 2003   128 Mbytes of RAM minimum, 256 Mbytes of RAM recommended   100 Mbytes of free hard disk space (or more based on application requirements)   256-color VGA graphics adapter, 800 x 600 minimum resolution (True Color 1024 × 768 recommended)   CD-ROM drive

Package Contents

The following components are included with your MVI56E-MNETCR module, and are all required for installation and configuration.  

Setting Jumpers

The Setup Jumper acts as "write protection" for the module’s flash memory. In "write protected" mode, the Setup pins are not connected, and the module’s firmware cannot be overwritten. Do not jumper the Setup pins together unless you are directed to do so by ProSoft Technical Support.   The following illustration shows the MVI56E-MNETCR jumper configuration.

Installing the Module in the Rack

If you have not already installed and configured your ControlLogix processor and power supply, please do so before installing the MVI56E-MNETCR module. Refer to your Rockwell Automation product documentation for installation instructions.

After you have checked the placement of the jumpers, insert the MVI56E MNETCR into the ControlLogix chassis. Use the same technique recommended by Rockwell Automation to remove and install ControlLogix modules. You can install or remove ControlLogix system components while chassis power is applied and the system is operating. However, please note the following warning.  

1 Align the module with the top and bottom guides, and then slide it into the rack until the module is firmly against the backplane connector.

2 With a firm, steady push, snap the module into place.

3 Check that the holding clips on the top and bottom of the module are securely in the locking holes of the rack.

4 Make a note of the slot location. You must identify the slot in which the module is installed in order for the sample program to work correctly. Slot numbers are identified on the green circuit board (backplane) of the ControlLogix rack.

5 Turn power ON.


  • Hirschmann MM20-M4M4T1T1SBH Industrial Ethernet module
  • IC752SPL011 GE control panel
  • GE ALSTOM IR139-1丨063022350丨80801419丨B0037299control card
  • ALSTOM UT150-1 control module
  • ALSTOM AL132丨AL132A Control Card
  • ABB 2CTB802342R0000 surge protector
  • ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • Tektronix TDP0500 high pressure differential probe
  • Carrier CEPL130403-02-R Microprocessor Board CEBD430403-11-RC 32GB500382EE
  • BENTLY 106M1079-01-Y Power Module Original
  • ABB system module DLM02 original DO610,DO620
  • 1394-SJT22-A servo driver Allen-Bradley servo equipment
  • MOTOROLA SGLF4136FA PLC control system
  • B&R ECPE84-1B Modulus Input Module Quality Service
  • Foxboro FBM213 communication module supply
  • S-093H 3BHB030478R0309 ABB high voltage frequency conversion rack
  • ABB S-123H 3BHB030479R0512 rack
  • ABB 3BHL000406P0103 VFW 30/265Processor unit
  • ALSTOM V4561983-0100 EPIC II ESP controller
  • MOOG G761-3004B5 H38JOGM5VPH Servovalve
  • 3500 BentlyNevada 3500/05-02-01-00-00-00 System rack
  • 3500/05-01-02-00-00-01 Bently Nevada 3500/05 System Rack
  • 3500/05-01-01-00-00-00 BentlyNevada System Rack
  • BentlyNevada 3500/05-02-01-01 System Rack
  • 3500/05-01-01-01-00-00 Bently Nevada 3500/05 System frame
  • BentlyNevada3500/95 System Integrated PC Display
  • 3500/93 Bently Nevada System Display
  • General electric IS215GBIAH1A auxiliary Genius bus interface module
  • MOOG D137-004-006 Servo valve controller
  • MOOG D137-004-005 Industrial controller
  • MOOG D137-004-004 Motion controller
  • D137-004-003 MOOG RDISP 22 operation panel
  • MOOG D138-002-003
  • MC 600 SERIES D138-002-002 MACHINE CONTROLLER MOOG
  • MOOG D138-002-001
  • MOOG B95914-001 Plate and fittings
  • D138-003-010 - Visualization HMI run time license (MACS HMI) for 10 machines
  • MOOG MACS HMI 1 - D138-003-001
  • MOOG D137-002-001 control module
  • MOOG QEBUS-CAN - D137-001-010
  • MOOG QAIO 16/4-V - D137-001-007
  • MOTOROLA MVME7100 - High-Speed Embedded Controller, VME
  • Motorola MVME2432 - VME Embedded Controller
  • Motorola СPU3640FLN3524A - Embedded Processor Module
  • MOTOROLA MVME187-24B01-W36908 - High-Performance
  • Motorola MVME162P-344 - VME Controller, 68040 Processor, Industrial Automation
  • Motorola FLN4234A - Embedded System Controller
  • Motorola MVME2604712 I/O-VME board
  • MOTOROLA MVME-51005E-0163-VME Embedded Controller
  • MOTOROLA MVME162PA-344SE - VME Controller
  • MOTOROLA MVME6100-0161 - High-Performance VME Board
  • MOTOROLA MVME55006E-0161R - Enhanced Performance VME Controller
  • MOTOROLA MVME162-523A - VME Controller
  • Motorola PCB MVME 2434 SBC PMC-HS/GE FANUC PMC661J card
  • Motorola MVME55006E-0163-VME processor board
  • MOTOROLA VME162PA344SE - Enhanced VME Controller
  • MOTOROLA MVME5500 - High-Performance VME Controller
  • MOTOROLA MVME147-023 - Legacy VME Board, Embedded Controller, Industrial Automation
  • MOTOROLA VME162PA-252SE - VME Board, Legacy System Controller, Industrial Automation
  • MOTOROLA MVME6100+5264- VME Board with Memory Expansionerformance Industrial Controller
  • MOTOROLA MVME2305-900 - VME Embedded Controller
  • Motorola MVME3100-1152-Enhanced VME Controller
  • Motorola MVME147-012-Traditional VME Board
  • Motorola MVME147-013-Traditional VME Board
  • MOTOROLA MVME-5101-0131-VME Embedded Controller
  • MOTOROLA MVME5101-0131 - VME Embedded Controller
  • MOTOROLA MVME167P-24SE - VME Controller
  • Motorola MVME7100-0171 - High-Speed Embedded Controller
  • MOTOROLA MVME3100 - High-Performance VME Controller
  • MOTOROLA MVME147-010 - Legacy VME Board,
  • MOTOROLA MVME55006E-0163R - Enhanced Performance VME Controller, Industrial Control Systems
  • MOTOROLA MVME5110-2261 - Enhanced VME Controller
  • MOTOROLA MVME2305-900 - VME Embedded Controller
  • MOTOROLA MVME5100-0163 High-Performance VME Embedded Controller
  • MOTOROLA MVME-147A0-60063-1 - Legacy VME Board, Industrial Automation Applications, Embedded Systems
  • MOTOROLA IPMC761-001 - PMC Carrier Board
  • MOTOROLA MVME6100-163 - Enhanced VME Controller
  • MOTOROLA MVME162-213 - Embedded Controller
  • MOTOROLA MVME162-022A - Embedded VME Board
  • MOTOROLA MVME61006E-0163R+P.N5264 - VME Processor Board
  • MOTOROLA MVME61006E-0161R+P.N5264 - Enhanced VME Processor Board, 1.3 GHz, Memory Card Supported
  • MOTOROLA MVME6100 (01-W3878F14B) - VME Embedded Controller
  • MOTOROLA APPLIED0100-01396 - Applied Computing Board
  • MOTOROLA MVME162PA-344 - VME Controller
  • MOTOROLA MVME2100 - Low-Cost Embedded VME Board
  • Motorola MVME5100-VME embedded controller, high-speed data processing.
  • MOTOROLA MVME162-202 - Embedded Controller, VME
  • MOTOROLA MVME7100-0173-2G - Embedded Controller
  • TRICONEX 2301 - Digital Output Module, High-Speed, Industrial Systems
  • TRICONEX 2351 Analog Input Module, High-Precision
  • TRICONEX 2401-Digital Input Module, Compact
  • TRICONEX 2101 Main Processor Module, Modular, High-Performance
  • TRICONEX 2381 - Digital Input Module, Compact Design, High-Precision
  • TRICONEX 9566-810 Power Supply Module, Modular
  • TRICONEX 8312 - Communication Module
  • TRICONEX FTA-544 Termination Assembly Modular
  • TRICONEX 3604E - TMR Digital Output Module, High-Precision
  • TRICONEX 9566-810F Power Supply Module, Compact
  • TRICONEX 3451 Analog Input Module, Compact
  • TRICONEX 3211S-analog input module
  • TRICONEX DI3301S2 Digital Input Module
  • TRICONEX 3481S2 Analog Output Module, Redundant
  • TRICONEX 3511 Main Processor Module, Modular
  • TRICONEX 3101 Main Processor Module
  • TRICONEX 8111 Communication Module
  • TRICONEX 4210 Analog Input Module
  • TRICONEX 4211 Analog Input Module
  • TRICONEX CIM3211S2 Communication Interface Module
  • TRICONEX MA2211-100S2 Communication Module, Redundant
  • TRICONEX MA2211-100 Communication Module, Compact
  • TRICONEX AO3481 Analog Output Module
  • TRICONEX 3501TN2 - Main Processor Module
  • TRICONEX 3623T Digital Output Module High-Precision
  • TRICONEX 3009 Main Processor Module, High-Speed
  • TRICONEX 3009X - Main Processor Module
  • TRICONEX 8310 Communication Module
  • TRICONEX 3008 - Main Processor Module, Modular, High-Speed
  • TRICONEX 3301-Digital Input Module
  • TRICONEX 3700A-Communication module, high performance
  • TRICONEX 3504E - Main Processor Module
  • TRICONEX 3503E Main Processor Module
  • TRICONEX 3481S Analog Output Module
  • TRICONEX 3351 Analog Input Module
  • TRICONEX 3401 Analog Input Module
  • TRICONEX RXM4201 Communication Module
  • TRICONEX RXM4200-3 - Communication Module
  • TRICONEX 3624 Digital Output Module
  • TRICONEX 3704E - Digital Input Module