KONG -Y
NameDescriptionContent
Location:

MVME55006E P/N: 6806800A37L Installation and Use Motorola

From: | Author:kongjiang | Time :2025-03-03 | 944 Browse: | 🔊 Click to read aloud ❚❚ | Share:

MVME55006E P/N: 6806800A37L  Installation and Use Motorola

Safety Notes

system to show compliance with the above mentioned requirements. A proper installation 

in a compliant system will maintain the required performance. Use only shielded cables 

when connecting peripherals to assure that appropriate radio frequency emissions 

compliance is maintained.

Operation 

Installation Data Loss Powering down or removing a board before the operating system or other software running on the board has been properly shut down may cause corruption of data or file systems. Make sure all software is completely shut down before removing power from the board or removing the board from the chassis. Product Damage Only use injector handles for board insertion to avoid damage to the front panel and/or PCB. Deformation of the front panel can cause an electrical short or other board malfunction 

Product Damage High humidity and condensation on the board surface causes short circuits. Do not operate the board outside the specified environmental limits. Make sure the board is completely dry and there is no moisture on any surface before applying power. Damage of Circuits Electrostatic discharge and incorrect installation and removal can damage circuits or shorten its life. Before touching the board or electronic components, make sure that you are working in an ESD-safe environment. Board Malfunction Switches marked as Reserved might carry production-related functions and can cause the board to malfunction if their setting is changed. Do not change settings of switches marked as Reserved. The setting of switches which are not marked as “reserved” has to be checked and changed before board installation.

Product Damage Inserting or removing modules with power applied may result in damage to module components. Before installing or removing additional devices or modules, read the documentation that came with the product

Cabling and Connectors 

 Product Damage RJ-45 connectors on modules are either twisted-pair Ethernet (TPE) or E1/T1/J1 network interfaces. Connecting an E1/T1/J1 line to an Ethernet connector may damage your system. 

  Make sure that TPE connectors near your working area are clearly marked as network connectors 

 Verify that the length of an electric cable connected to a TPE bushing does not exceed 100 meters 

  Make sure the TPE bushing of the system is connected only to safety extra low voltage circuits (SELV circuits) If in doubt, ask your system administrator

Battery

Board/System Damage Incorrect exchange of lithium batteries can result in a hazardous explosion. When exchanging the on-board lithium battery, make sure that the new and the old battery are exactly the same battery models. If the respective battery model is not available, contact your local Penguin Solutions sales representative for the availability of alternative, officially approved battery models. Data Loss Exchanging the battery can result in loss of time settings. Backup power prevents the loss of data during exchange. Quickly replacing the battery may save time settings. Data Loss If the battery has low or insufficient power the RTC is initialized. Exchange the battery before seven years of actual battery use have elapsed

Board/System 

Damage Incorrect exchange of lithium batteries can result in a hazardous explosion. When exchanging the on-board lithium battery, make sure that the new and the old battery are exactly the same battery models. If the respective battery model is not available, contact your local Penguin Solutions sales representative for the availability of alternative, officially approved battery models. Data Loss Exchanging the battery can result in loss of time settings. Backup power prevents the loss of data during exchange. Quickly replacing the battery may save time settings. Data Loss If the battery has low or insufficient power the RTC is initialized. Exchange the battery before seven years of actual battery use have elapsed

Hardware Preparation and Installation

Overview

This chapter contains the following information: 

  Board and accessory preparation and installation instructions 

  ESD precautionary notes

Introduction

The MVME55006E is a single-board computer based on the PowerPC MPC7457 processor and the Marvell GT-64260B host bridge with a dual PCI interface and memory controller. On-board payload includes two PMC slots, two SDRAM banks, an expansion connector for two additional banks of SDRAM, 8MB boot flash ROM, one 10/100/1000 Ethernet port, one 10/100 Ethernet port, 32MB expansion flash ROM, two serial ports, NVRAM and a real-time clock. The MVME55006E interfaces to a VMEbus system via its P1 and P2 connectors and contains two IEEE 1386.1 PCI mezzanine card (PMC) slots. The PMC slots are 64-bit and support both front and rear I/O. Additionally, the MVME55006E is user-configurable by setting on-board jumpers. Two I/O modes are possible: PMC mode or SBC mode (also called 761 or IPMC mode). 

  The SBC mode uses the IPMC712 I/O PMC and the MVME712M transition module, or the IPMC761 I/O PMC and the MVME761 transition module. The SBC mode is backwards compatible with the MVME761 transition module and the P2 adapter card (excluding PMC I/O routing) used on the MVME5100 product. This mode is accomplished by configuring the on-board jumpers and by attaching an IPMC761 PMC in PMC slot 1. Secondary Ethernet is configured to the rear. 

  PMC mode is backwards compatible with the MVME5100 and is accomplished by configuring the on-board jumpers.

Getting Started

This section provides an overview of the steps necessary to install and power up the MVME55006E and a brief section on unpacking and ESD precautions.

Overview of Startup Procedures

The following table lists the things you will need to do before you can use this board and tells where to find the information you need to perform each step. Be sure to read this entire chapter, including all caution and warning notes, before you begin

Unpacking Guidelines

Unpack the equipment from the shipping carton. Refer to the packing list and verify that all items are present. Save the packing material for storing and reshipping of equipment. If the shipping carton is damaged upon receipt, request that the carrier’s agent be present during the unpacking and inspection of the equipment.

Configuring the Hardware

 This section discusses certain hardware and software tasks that may need to be performed 

prior to installing the board in a chassis.

To produce the desired configuration and ensure proper operation of the MVME55006E, you may need to carry out certain hardware modifications before installing the module. Most options on the MVME55006E are software configurable. Configuration changes are made by setting bits in control registers after the board is installed in a system. Jumpers and switches are used to control those options that are not software configurable. These settings are described further on in this section. If you are resetting the board  jumpers or switches from their default settings, it is important to verify that all settings are reset properly.

  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • ADLINK SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO  HSL-4XMO-TB-D103  HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • ADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink PICMG Single Board Computers NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 ICMG Single Board Computers
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC