DESCRIPTION OF FUNCTION AND APPLICATION

Summary

Both analogue and binary I/P signals pass through a signal con ditioning stage before being processed by the main processor: Analogue signals go through the chain comprising the input transformer, shunt, low-pass filter (anti-alias filter), amplifier, sampling (sample and hold), multiplexer and A/D converter. As digital signals they are then separated by digital filters into real and apparent components before entering the main processor. The binary signals are isolated by opto-couplers in the input cir cuits and are evaluated by the main processor. Only now are the protection algorithms and the logic functions processed in the main processor.

A delay function and a logic function are also included. The de lay function enables a time to be defined between pick-up (I/P of the function)  and its operation. A setting is also provided for the reset time. The logic function provides an AND, OR or RS gate for combining different O/P signals (of functions and binary I/P’s).

The distance protection function is equipped with overcurrent or underimpedance starters. In ungrounded systems, all the usual cyclic and acyclic phase preference schemes are available.

The residual (neutral) current and/or residual (zero-sequence) voltage are monitored to detect earth faults.

The first distance zone, the overreaching zone and the reverse zone measure simultaneously. All of the distance zones have wide setting ranges and can be set completely independently of each other, also with respect to whether they measure in the forwards or reverse direction. There are three directional dis tance zones and a fourth, which can be either directional or non directional as demanded by the application. The overreaching and reverse zones are for use in transfer tripping schemes with signal transmission between the units at the two ends of a line. The operating characteristics are polygons with the reactance borders slightly inclined to give an ideal tripping area. For close three-phase faults with very low voltages, the use of a reference voltage comprising a healthy voltage and the voltage of a mem ory feature ensures a reliable directional decision.

Compensation of the mutual zero-sequence impedance of paral lel circuits can be achieved by appropriate selection of the zero sequence impedance factor (k0) or the residual current of the parallel circuit using k0m.

A v.t. supervision feature (fuse failure) is already incorporated. Its measurement can be based on either the zero-sequence component (U0 . not I0) and/or the negative-sequence compo nent (U2 . not I2). The latter is of special advantage in un grounded systems or systems with poor grounding.

An independent back-up overcurrent function becomes a short zone protection, as soon as the line isolator is opened. Tripping of the overcurrent back-up protection is uninfluenced by any signal, which may be blocking the distance protection (e.g. v.t. supervision or power swing blocking).

The power swing blocking function monitors the variation of the quantity U . cos . This method of detecting power swings is en tirely independent of the characteristic and location of the dis tance protection. Power swings with frequencies between 0.2 and 8 Hz are detected.

The sensitive E/F protection for ungrounded systems and sys tems with Petersen coils measures both in the forwards and re verse directions. A characteristic angle of 90 (U0 . I0 . sin ) is chosen for ungrounded systems and one of 0 (U0 . I0 . cos ) for systems with Petersen coils.

An logic, which can be freely programmed with the aid of FUPLA (function block programming language), provides convenient fa cility for achieving special circuits needed for specific applica tions.

The auto-reclosure function enables up to four three-phase re closure cycles to be carried out, each with independently set dead time for fast or slow auto-reclosure.

Where necessary, a large variety of supplementary protection and logic functions is contained in the RE. 216 and RE. 316*4 function software libraries.

The distance protection logic gives the user access for blocking or enabling purposes to a wide range of functions, including for example the kind of transfer tripping scheme, switch-onto-fault logic, zone extension logic, v.t. supervision logic and whether the protection should trip just the phase concerned or all three phases for an E/F.

The memory of the event recorder function has sufficient capac ity for up to 256 binary signals and their relative time tags.

The memory of the disturbance recorder registers 12 analogue and 16 binary signals. The number of events it can actually re cord depends on the total duration of an event as determined by the amount of pre-event data (event history) and the duration of the event itself.

Where necessary, a large variety of supplementary protection and logic functions is available in the MODURES 216 function software library, which can provide other protection functions such as restricted earth fault protection or standstill protection.

Restricted E/F protection for a transformer

  • Vibro-Meter CPU controller   CPUM Mk2  600-050
  • Vibro-Meter I/O interface card    IOC10 Mk2 (rear card)    600-046
  • Vibro-Meter Temperature / Analog Acquisition  AMC10 Mk2  600-042
  • Vibro-Meter I/O interface card IOC4 Mk2 600-043
  • Vibro-Meter Protective measuring card MPC4 Mk2 SIL2 601-041-A10
  • Vibro-Meter Protective measuring card MPC4 Mk2 601-041-A0
  • Vibro-Meter PSU-VM600 VM600 Rack Power Module
  • Vibro-Meter ABE056 - 1U ultra-thin single-rack
  • Vibro-Meter ABE046 - 6U 19-inch rack
  • Vibro-Meter ABE045 - 6U 19-inch rack
  • Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)
  • Vibro-Meter ABE042 6U 19-inch rack (4 slots)
  • Vibro-Meter I/O interface card XIO16T
  • Vibro-Meter XMC16 16-channel combustion monitoring card
  • Vibro-Meter XMV16 - 16-channel vibration condition monitoring card
  • Vibro-Meter RLC16 Relay Card
  • Vibro-Meter IRC4 Intelligent Relay Card
  • Vibro-Meter IOCR2 input/output rear interface card
  • Vibro-Meter CPUR2 Central Processing and Controller Card
  • Vibro-Meter I/O interface card  -  IOCR
  • VIBRO-METER CPU controller CPUR
  • VIBRO-METER IOCN 200-585-000-322 I/O interface card
  • VIBRO-METER IOCN 200-585-000-321 I/O Interface Card
  • VIBRO-METER 200-595-074-323 VM600 system CPU management card, non-redundant
  • VIBRO-METER CPUM 200-595-074-322 CPU Controller
  • VIBRO-METER CPU controller CPUM 200-595-070-321
  • Vibro-Meter IOC8T VM600 Mk1 I/O Interface Card
  • Vibro-Meter AMC8 Analog Monitoring Card
  • VIBRO-METER IOC4G2 I/O interface card
  • VIBRO-METER MPC4G2 Protective measuring card
  • VIBRO-METER IOC4T 200-560-101-017 VM600 Mk1 Isolated I/O Interface Card, equipped with MPC4
  • VIBRO-METER IOC4T 200-560-101-015 VM600 Mk1 interface card
  • VIBRO-METER IOC4T 200-560-000-114 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-113 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-111 Sensor wiring
  • VIBRO-METER MPC4 200-510-072-212 Protection Measurement Card
  • VIBRO-METER MPC4 200-510-071-114 Protective Measurement Card
  • VIBRO-METER 200-510-071-111 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-070-111 4-channel vibration protection + 2-speed channels
  • ADLINK PICMG Single Board Computers NuPRO-E315
  • ADLINK High Speed Link (HSL) PCI-7853
  • ADLINK Digital I/O PCIe-7432
  • ADLINK Mini-ITX Embedded Boards AmITX-AL-I
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6860A
  • ADLINK NuPRO-900A PICMG Single Board Computers
  • ADLINK Analog Output PCI-6308 Series
  • ADLINK USB DAQ USB-2405
  • ADLINK CRR-LX800-E-500 Compact Industrial Computer Module (COM)
  • ADLINK 15-slot 6U PXI/CompactPCI Chassis with AC PXIS-3320
  • ADLINK NUPRO-842 PICMG Single Board Computers
  • ADLINK PCI-8124-C Advanced 4-CH Encoder Card
  • ADLINK PCI-8102 Centralized Motion Controllers PCI-8102
  • ADLINK PCIe-7200 High-Speed DIO
  • SEL SEL-7201 Feeder Protection Panel
  • SEL SEL-7206 Distribution Bus Differential Protection Panel
  • SEL SEL-4388 Mirrored Bits Tester
  • SEL SEL-T4287 Traveling-Wave Test System
  • SEL SEL-4000 Relay Test System
  • SEL SEL-9510 Control Switch Module
  • SEL SEL-9502 Contact Arc Suppressor
  • SEL SEL-9501 Contact Arc Suppressor
  • SEL SEL-2652 Trip Coil Monitor
  • SEL SEL-2894 Interface Converter
  • SEL SEL-2890 Ethernet Transceiver
  • SEL SEL-2886 EIA-232 to EIA-485 Interface Converter
  • SEL SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
  • SEL SEL-2824 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2820 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2815 Fiber-Optic Transceiver/Modem
  • SEL SEL-2814 Fiber-Optic Transceivers With Hardware Flow Control
  • SEL SEL-2812 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2810 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2831 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2830 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2829 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-C805 200 µm Multimode Fiber-Optic Cable
  • SEL SEL-C804 Multimode Arc-Flash Detection Fiber-Optic Cables
  • SEL SEL-9331 Power Supply
  • SEL SEL-9322 15 VDC Power Supply
  • SEL SEL-9321 Low-Voltage DC Power Supply
  • SEL SEL-LPS Linear Power Supply
  • SEL SEL-RPM Redundant Power Module
  • SEL SEL-7250 Digital Direct-Replacement Assemblies
  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software