• Minimize the hardware required
• Reduce capital and operational costs
• Future-proof investments
Delivering continuous operation
The TÜV-certified Tricon CX SIL3 system delivers the highest levels of safe operation and maximum plant availability throughout the operating life of the plant. Tricon CX combines the best of the world’s most proven Tricon and Trident platforms and can be used in both low- and high-demand modes. Inherent high integrity and high availability is built into the systems. Diagnostics and redundancy management are transparent to the user. The system adapts and maintains SIL3 even under
fault conditions. The TMR design ensures no single point of failure. The 2oo3D (two out of three diagnostic) architecture and voting eliminates spurious trips, increases plant uptime, extends plant maintenance cycles, and lowers operational costs.
Unlike other safety systems, voting and diagnostics are built in — no user logic is required. There is no need for redundant I/O modules to achieve fault tolerance. The use of a hot spare is not required to increase mean time to failure. Each Tricon CX system contains three physically separate main processor modules that continue to operate even under fault conditions. The system supports adaptive voting 3-2-1-0 or 3-2-0. Processor modules can be replaced online without stopping operation. Each Tricon CX system can accommodate up to four communications modules in two redundant pairs. Each module is physically separate, so can be replaced online if required without halting operations. Each I/O module is triplicated by design. Redundant I/O modules are not required to achieve fault tolerance. I/O modules are fault tolerant and continue to operate even under fault conditions. Modules can be replaced online, switch over is automatic, and redundancy management is transparent.
Features of the Tricon CX design include:
• High integrity and high availability are built-in
• Diagnostic and redundancy management is transparent to the user
• Maintains SIL3 even under fault conditions
• Redundant I/O modules are not required to achieve fault tolerance
• Processor, communications, and I/O modules can be replaced online without halting operations
• Modifications can be made without stopping operations
Model number
8120X Main chassis
8131X I/O chassis
3009X Main processor, 256 Mb
4355X Triconex Communication Module
4610X Unified Communication Module
4701X I/O bus interface module, RS-485 Serial-Serial
3506X Supervised digital input module 32 channels, 24 VDC Supervised, TMR
3626X Supervised digital output module 32 channels, 24 VDC, Supervised, commoned, TMR
3722X Analog input module 32 channels, 0 – 5 VDC, Fast, No-HART, TMR
3723X Analog input module 32 channels, 0 – 5 VDC, HART, TMR
3809X Analog output module 16 channels, 0 – 23 mA, HART, TMR
3902X Universal safety I/O module 16 channels, TMR Analog inputs + HART Supervised digital inputs nAnalog outputs + HART Supervised digital outputs
3506X DI, Supervised
3626X DO
3722X Al
3723X Al + HART
3809X AO + HART
3902X Universal I/O with HART