VE6041F01C1 Интеллектуальный переключатель сети DeltaV Emerson
Introduction
Plug-and-play installation
Auto security lockdown
A full line of Industrial Rated Fanless Switches
Fully supported by Emerson
Introduction
The DeltaV Network ―Smart‖ switches are the next generation in the use of commercial off-the-shelf (COTS) components in control systems. Called ―purpose-built‖ commercial components these switches combine the lower cost of off-the-shelf components with DeltaV specific software and features to make them more integrated and plug and-play in the control network. DeltaV Smart Switches require no configuration to function in the DeltaV network. Accessing the advanced features takes only minor configuration that is easy to perform using the DeltaV Wizard and secured so you can’t incorrectly configure any switching functions that impact the performance of the DeltaV system. The purpose-built switch also allows the DeltaV system to provide an auto port lockdown advanced security feature that is easy for a control system user to implement: an increasingly important product feature in today’s hostile environment.
Product Description and Specification
The DeltaV network ―smart‖ switch is a Fast- Ethernet Layer 2 network switching device. The switch is available in three models: The VE6046, VE6047 and VE6048 DeltaV Smart Switch: 19‖ rack-mountable 8, 16 or 24-port modular switch with wired and fiber connections and 2 Gigabit wired or fiber uplinks. The VE6041 DeltaV Smart Switch: a DIN rail 8-port 10/100 MB switch with fiber and wire uplinks. Available in standard and extended temperature/ conformal coated versions. The VE6042 and VE6043 DeltaV Smart Switch: a DIN rail-mounted modular switch supporting 8, 16 or 24 ports using wired and fiber communications modules. The VE6043 provides 2 Gigabit wired or fiber uplinks in addition to the 24 local ports. Available in standard and extended temperature/conformal coated versions.
DeltaV Plug-and-Play Installation
The DeltaV switches are easy to install in your DeltaV network. Since they come preconfigured from the factory, installation is as simple as mounting the unit, connecting the communications cables, and powering up the unit. The switch is configured to begin communications on power up—no additional setup is required for the switching function to work properly.
Auto Security Lockdown
The DeltaV Smart Switch has our patent-pending auto lockdown security technology to prevent unauthorized access to the network. The DeltaV one-click lockdown application will automatically locate all of the Smart Switches in the network and display their locked or unlocked status. While any user can view the switch security status only users with Can Download, Can configure and Can Calibrate privileges are able to lock and unlock the switches. The DeltaV one-click lockdown security application will send a lock or unlock command to all the switches in the network with a single click. The ―lock‖ command tells the switch to find all of the unused network ports and disable them. It will also memorize what devices are connected on each local port to prevent an existing device from being replaced by an unauthorized rogue device. Another single click will command all the switches to ―unlock‖ to add a new device or to troubleshoot any network problems. The optional 60 minute relock timer will automatically relock all of the switches to prevent the devices from accidentally being left in the insecure, unlocked state. This application can be run from just the ProfessionalPlus or can also be installed on operator or maintenance stations for easy user access. All locking and unlocking events are logged in the DeltaV Event Journal so you can easily monitor unlocking events for unusual activity and to be sure proper security procedures are being followed.
Network Monitoring
The Smart Switch provides view-only access to the switch network monitoring capabilities. Using a third party SNMP application (such as ―What’s Up Gold‖) and standard SNMPv3 communications, you can collect network data and monitor the health of the switch. Since this is view-only access, there is no chance the monitor access will allow any configuration changes to the switch providing secure monitor access. In addition, you can use the built-in web interface on the switch to use the browser on your switch management workstation* for a view-only user interface to access switch information.
The view only Web interface provides a secure and easy to-navigate view into the internal switch status information.
Switch Setup—DeltaV Wizard
The DeltaV smart switch is easy to set up using the DeltaV Wizard build into the switch. By simply connecting the serial cable and running a terminal access application such as Hyperterminal (included on the XP-based DeltaV workstations), you can easily enable the advanced features using a simple question and answer format. Only the switch settings allowed by the wizard are user accessible in the switch. See the Wizard parameter table at the end of this document for details The DeltaV Wizard allows any user to easily setup the switch without having to worry about accidentally changing the proper configuration needed for DeltaV. The Ease-of-Use Wizard prevents users from entering a non-DeltaV network address by limiting the address choices to only those available within
the DeltaV LAN. The subnet address is preconfigured for DeltaV to make this setup even easier.
Switch Access Security
All user access to the switch is protected by passwords. The DeltaV Wizard provides a question and-answer format to change the default passwords, if desired. The switch is set up by default to allow remote access for view-only user functions and to access the Setup Wizard to make setup changes over the network. If desired, either or both of these remote access capabilities can be disabled using the wizard. If Telnet is disabled, the only configuration access to the switch will be via the serial connection directly at the switch. Disabling remote access has no impact on the one-click lockdown function. SNMP v3 access is always enabled in a view-only mode.
Compatible with all Versions of the
DeltaV System
Switches are compatible with all versions of DeltaV for switching and monitor functions and can be used to expand or retrofit existing DeltaV systems and for replacement spares for some existing Cisco and Hirschmann switches—the auto switch lockdown is compatible only with DeltaV v10.3.
Compatible with non-DeltaV Switches
The DeltaV Smart Switch can also be installed in a
mixed system with the currently supported Cisco or
Hirschmann switches, as desired.
Reliable Hardware
The DeltaV Smart Switch is based on hardware
produced by a recognized supplier of industrial
grade networking equipment. All switches are fan-
less and have redundant power connections with
external alarm contacts. They are also available in
high temperature, conformal coated versions for use
in harsh environments.
VE6041F01C1
VE6041F01C2
VE6041F03C1
VE6041F03C2
VE6041F04C1
VE6041F04C2
VE6041F05C1
VE6041F05C2
VE6041F06C1
VE6041F06C2
VE6041F07C1
VE6041F07C2
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com
Website: https://www.abb-sis.com