GE 151X1233DB01SA01R4 Wind turbine pitch control I/O blue box
GE 151X1233DB01SA01R4 Wind turbine pitch control I/O blue box
R4 replaces R3/R2; interchangeable with DB01SA
PowerConversion Module(Thyristor SCR)
Negative forcing provides fast
response for load rejection and
de-excitation.
M1and M2are identical.
For EX2100e Static exciter control systems, the 3-phase, full-wave, inverting thyristor
(SCR) is the standard Power Conversion Module (PCM). The inverting bridge can
provide both positive and negative forcing voltage for optimum performance. Each
rectifier bridge includes thyristor protection circuitry, such as snubbers, filters, and fuses.
The thyristor bridge module is forced-air cooled. For most applications, redundant
cooling modules that are normally energized during operation are used. A thermistor
monitors the PCM temperature. A set of alarm and trip contacts trigger an alarm at a high
temperature level, and a trip at a higher temperature level.
Depending on the application, the PCM may include protective components for the SCRs.
Aconduction sensing circuit, in coordination with the controller software, monitors each
SCRbridge for blown fuses, missing gate pulses, or open/shorted SCRs. Reactors are
located in the ac legs that are feeding the SCRs. The snubbers are a resistor/capacitor
(RC) circuit from the anode to the cathode of each SCR. The cell snubbers, line-to-line
filters, and line reactors together perform the following functions to maintain proper
operation of the SCRs:
• Limitthe rate of change of current through the SCRs and provide a current dump to
aid in starting conduction
• Limitthe rate of change in voltage across each cell
• Limitthe reverse voltage that occurs across the cell during cell commutation
2.3 Controller Redundancy
In the warm backup (WBU) and multi-bridge configurations, the EX2100e control
features redundant control with triple modular redundancy (TMR) for voted I/O and
protection, including the field ground detector (FGD) function. The control includes
Master One (M1), Master Two (M2), and Controller (C) modules. M1 and M2 are

independent controls, each with automatic and manual regulator functions. Either M1 or
M2can control the bridge firing, as determined by the operator, or a forced transfer by C.
In the WBU configuration, M1 controls bridge #1. and M2 controls bridge #2. In the
multi-bridge configuration, the Master in control fires all bridges. The M1 and M2 control
modules each contain a UCSB controller for processing the application software. The C
controller is responsible for M1/M2 transfer and provides the third element of TMR I/O
and protection.
In the redundant control, simplex bridge configuration, M1. M2. and C, are provided with
a single bridge. In the simplex control configuration, only the M1 control and a single
bridge are provided, and only a simplex FGD is available
| 1394C-SJT10-A SERCOS interface Multi-Axis system module |
| 1394-SJT10-C-RL GMC system module |
| 1326AB-B420E-21 1326AB brushless servo motor |
| REF620 NBFNAAAAABC1BBN1XF dedicated feeder IED perfectly |
| PR6423/011-110+CON021 Eddy Current Signal Converter |
| PPC322BE HIEE300900R1 High-performance input/output modules |
| A06B-6141-H006 #H580 ALPHA i SPINDLE MODULE MDL AiSP- 5.5 |
| A06B-6141-H006 #H580 Power Supply Module |
| IC695CPE310-ACAT RX3i Mid range controller |
| A06B-0288-B100#0046 Power Supply Module |
| 330104-00-05-05-11-05 3300 XL 8mm Proximity Transducer System |
| 2711P-RDT15CB PanelView Plus 6 1500 Touch operated terminals |
| 22F-D4P2N103 PowerFlex adjustable AC Frequency Drive |
| 1783-BMS10CGN Managed Ethernet switch |
| CP471-01 Processor Module YOKOGAWA |
| FC-RUSIO-3224 Remote Universal Safe IO device |
| IS220UCSAH1A-C PAMC Acoustic Monitor (Processor) |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com