TRICONEX 2382 непревзойденная производительность в автоматизированных решениях
Second, the technical specifications and functional characteristics
Although the detailed parameters of 2382 are not clearly listed in the data, combined with the overall architecture of Triconex system and the specifications of similar modules, it can be inferred that its core characteristics are as follows:
Redundant fault-tolerant design
Based on TMR architecture, three independent channels run in parallel, and the single point of failure is eliminated by 2/3 voting mechanism to ensure the continuity and reliability of the output signal.
Support online hot plug and module-level repair to reduce system downtime.
Industrial compatibility
Support multiple voltage levels (such as 24VDC, 115VAC, 230VAC) to meet the needs of different industrial environments.
The mechanical key lock is designed to prevent incorrect installation and ensure the physical matching between the module and the slot.
Diagnosis and maintenance
Built-in real-time diagnosis function can detect hardware faults (such as communication interruption and power fluctuation) and record them to system variables, supporting remote monitoring.
It conforms to IEC 61508 and TVAK6/SIL 3 certification, and is suitable for scenes with strict requirements of safety integrity level (SIL).
Communication integration
It is connected with the main processor (such as Model 3008) through the backplane, supports Modbus TCP, OPC and other protocols, and is easy to integrate with the upper computer or other control systems.
It can be used with the Remote Expansion Module (RXM) to realize the distributed I/O deployment up to 12km.
Third, application scenarios and industry cases
TRICONEX 2382 is mainly used in safety-critical industries, and its typical applications include:
Oil and gas
Used in emergency shutdown system (ESD) to trigger quick shutdown in case of pipeline leakage or equipment overvoltage.
Case: In the fire and gas detection system of a refinery, module 2382 controls the emergency closing action of explosion-proof valve to ensure the accident isolation efficiency.
Chemical industry and pharmacy
In the reaction kettle and mixing equipment, the safety interlock is controlled by digital signals to prevent the temperature or pressure from exceeding the limit.
Case: In the SIL 3 interlocking system of a chemical plant, the 2382 module ensures that the ventilation system will start automatically when toxic gas leaks.
Nuclear energy and electricity
As a part of Class 1E safety system of nuclear power plant, execute turbine protection and radiation monitoring instructions.
Case: The cooling pump control unit of a nuclear power plant adopts 2382 module to realize redundant output to deal with the main pump failure.
environmental monitoring
Integrated in pollution control system, driving alarm device or actuator, responding to abnormal water quality or air quality.
User name | Member Level | Quantity | Specification | Purchase Date |
---|
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com
Website: https://www.abb-sis.com