Phoenix  2904600  QUINT4-PS/1AC/24DC/5 - Power supply




QUINT4-PS/1AC/24DC/5 - Power supply

2904600

The fourth generation of the high-performance QUINT POWER power supplies ensures superior system availability by means of new functions.

Signaling thresholds and characteristic curves can be individually adjusted via the NFC interface.

The unique SFB technology and preventive function monitoring of the QUINT POWER power supply increase the availability of your application

Control input (configurable) Rem    Output power ON/OFF (SLEEP MODE)

Default    Output power ON (>40 kΩ/24 V DC/open bridge between Rem and SGnd)

AC operation

Supply system configuration    Star network

Nominal input voltage range    100 V AC ... 240 V AC

Input voltage range    100 V AC ... 240 V AC -15 % ... +10 %

Derating    < 100 V AC (1 %/V)

Electric strength, max.    300 V AC 60 s

Typical national grid voltage    120 V AC

230 V AC

Voltage type of supply voltage    AC

Inrush current    typ. 14 A (at 25 °C)

Inrush current integral (I2t)    < 0.3 A2s

Inrush current limitation    14 A (after 1 ms)

AC frequency range    50 Hz ... 60 Hz -10 % ... +10 %

Frequency range (fN)    50 Hz ... 60 Hz -10 % ... +10 %

16.7 Hz (acc. to EN 50163)

Mains buffering time    typ. 28 ms (120 V AC)

typ. 38 ms (230 V AC)

Current consumption    1.7 A (100 V AC)

1.5 A (120 V AC)

0.9 A (230 V AC)

0.8 A (240 V AC)

Nominal power consumption    163 VA

Protective circuit    Transient surge protection; Varistor, gas-filled surge arrester

Power factor (cos phi)    0.82

Switch-on time    < 500 ms

Typical response time    300 ms (from SLEEP MODE)

Input fuse    6.3 A (slow-blow, internal)

Recommended breaker for input protection    6 A ... 16 A (Characteristic B, C, D, K or comparable)

Discharge current to PE    < 3.5 mA

1.1 mA (264 V AC, 60 Hz)

DC operation

Nominal input voltage range    110 V DC ... 250 V DC

Input voltage range    110 V DC ... 250 V DC -18 % ... +40 %

Derating    < 110 V DC (1 %/V)

Voltage type of supply voltage    DC

Current consumption    1.6 A (110 V DC)

0.7 A (250 V DC)

Efficiency    typ. 88.8 % (120 V AC)

typ. 89.2 % (230 V AC)

Output characteristic    U/I Advanced

Smart HICCUP

FUSE MODE

Nominal output voltage    24 V DC

Setting range of the output voltage (USet)    24 V DC ... 29.5 V DC (constant capacity)

Nominal output current (IN)    5 A

Static Boost (IStat.Boost)    6.25 A

Dynamic Boost (IDyn.Boost)    10 A (5 s)

Selective Fuse Breaking (ISFB)    30 A (15 ms)

Magnetic circuit breaker tripping    A1 ... A4 / B2 / C1 ... C2 / Z1 ... Z4

Derating    > 60 °C ... 70 °C (2.5 %/K)

Feedback voltage resistance    ≤ 35 V DC

Protection against overvoltage at the output (OVP)    ≤ 32 V DC

Control deviation    < 0.5 % (Static load change 10 % ... 90 %)

< 4 % (Dynamic load change 10 % ... 90 %, (10 Hz))

< 0.25 % (change in input voltage ±10 %)

Residual ripple    < 30 mVPP (with nominal values)

Short-circuit-proof    yes

No-load proof    yes

Output power    120 W

150 W

240 W

Apparent power    180 VA (120 V, UOUT = 24 V, IOUT = stat. Boost)

198 VA (230 V, UOUT = 24 V, IOUT = stat. Boost)

Maximum no-load power dissipation    < 3 W (120 V AC)

< 3 W (230 V AC)

Power loss nominal load max.    < 17 W (120 V AC)

< 16 W (230 V AC)

Power dissipation SLEEP MODE    < 3 W (120 V AC)

< 3 W (230 V AC)

Crest factor    typ. 1.55 (120 V AC)

typ. 1.78 (230 V AC)

Rise time    50 ms (UOut = 10 % ... 90 %)

Connection in parallel    yes, for redundancy and increased capacity

Connection in series    yes

Fuse protection (secondary side)    electronic

thermal-magnetic

thermal

Signal

Signal ground SGnd    Reference potential for Out1. Out2. and Rem

Signal Out 1 (configurable)

Digital    24 V DC 20 mA

Default    24 V DC 20 mA 24 V DC for UOut > 0.9 x USet

Signal Out 2 (configurable)

Digital    24 V DC 20 mA

Analog    4 mA ... 20 mA ±5 % (Load ≤400 Ω)

Default    24 V DC 20 mA 24 V DC for POut < PN

Signal relay 13/14 (configurable)

Default    closed (Uout > 0.9 USet)

Digital    24 V DC 1 A

30 V AC/DC 0.5 A

Connection method    Screw connection

Conductor cross-section, rigid min.    0.2 mm²

Conductor cross-section, rigid max.    2.5 mm²

Conductor cross-section flexible min.    0.2 mm²

Conductor cross-section flexible max.    2.5 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, max.    2.5 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, max.    2.5 mm²

Conductor cross-section AWG min.    24

Conductor cross-section AWG max.    14

Stripping length    6.5 mm

Tightening torque, min    0.5 Nm

Tightening torque max    0.6 Nm

Output

Connection method    Screw connection

Conductor cross-section, rigid min.    0.2 mm²

Conductor cross-section, rigid max.    2.5 mm²

Conductor cross-section flexible min.    0.2 mm²

Conductor cross-section flexible max.    2.5 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, max.    2.5 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, max.    2.5 mm²

Conductor cross-section AWG min.    24

Conductor cross-section AWG max.    14

Stripping length    6.5 mm

Tightening torque, min    0.5 Nm

Tightening torque max    0.6 Nm

Signal

Connection method    Push-in connection

Conductor cross-section, rigid min.    0.2 mm²

Conductor cross-section, rigid max.    1 mm²

Conductor cross-section flexible min.    0.2 mm²

Conductor cross-section flexible max.    1.5 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, min.    0.2 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, max.    0.75 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, min.    0.2 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, max.    1.5 mm²

Conductor cross-section AWG min.    24

Conductor cross-section AWG max.    16

Stripping length    8 mm

Types of signaling    LED

Floating signal contact

Active signal output Out1 (digital, configurable)

Active signal output Out2 (analog, configurable)

Remote contact

Signal ground SGnd

Signal output

Signal option    Output current

Output voltage

Output power

UIN input voltage OK

Operating hours

Early warning of high temperatures

OVP voltage limitation active

POut    > 100 % (LED lights up yellow, output power > 120 W)

> 75 % (LED lights up green, output power > 90 W)

> 50 % (LED lights up green, output power > 60 W)

UOut    > 0.9 x USet (LED lights up green)

< 0.9 x USet (LED flashes green

CSA    CAN/CSA-C22.2 No. 60950-1-07

CSA-C22.2 No. 107.1-01

Shipbuilding approval    DNV GL, PRS, BV, LR, ABS

SIQ    BG (type approved)

UL approvals    UL Listed UL 508

UL/C-UL Recognized UL 60950-1

UL ANSI/ISA-12.12.01 Class I, Division 2. Groups A, B, C, D T4 (Hazardous Location)

MOLEX85003-0567
MOOGT161-902A-00-B4-2-2A
MOOGM128-010
MOOGG123-825-001
MOOGD136-001-007
MOOGD138-002-001
MOOGD138-002-002
MOOGD136-001-008
MOOGD136-001-008a
MOOGM128-010  M128-010-A001B
MOOGD136-002-005
MOOGD136E001-001
MOOGD136-001-001
MOOGD136-002-002
MOOGQAIO2/2-AV   D137-001-011




  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch