KONG -Y
NameDescriptionContent
Location:
product
SST   5136-RE-VME  communication interface module
❤ Add to collection

SST 5136-RE-VME communication interface module

SST   5136-RE-VME  communication interface module

U.S.$9800.00
U.S.$5600.00
U.S.$5320.00
U.S.$5208.00
Weight:1.290KG
Quantity:
(Inventory: 1)
Buy now
Add to cart
Description

SST   5136-RE-VME  communication interface module


SST 5136-RE-VME is an intelligent communication interface module designed for high-speed data exchange between a VMEbus host and Reliance Electric R-Net (or Remote I/O) networks.

Originally developed by SST (now part of Molex), this 6U VME card is a critical component for integrating Reliance Electric AutoMax systems with VME-based industrial computers.

By utilizing an onboard processor, the 5136-RE-VME offloads the complex R-Net protocol timing from the VME host,

 ensuring deterministic performance in high-speed motion and process control applications.

Technical Parameter Table

ParameterSpecification
Model Number5136-RE-VME
Form Factor6U VMEbus (Single Slot)
Processor16-bit High-Performance Microcontroller
Network ProtocolReliance Electric R-Net / Remote I/O
Memory512 KB Shared RAM Interface
Communication Speed800 kbps (Standard Reliance R-Net)
Bus CompatibilityVMEbus (A24/A16 Addressing, D16/D8 Data)
ConnectorFront-panel 9-pin D-Sub (Reliance R-Net)
Isolation500V DC Network Isolation
Power ConsumptionApprox. 1.2 A @ +5V DC
Operating Temp0°C to +60°C (32°F to 140°F)

Related Models

The SST "5136" family spans various industrial protocols for the VME backplane:

5136-PFB-VME: Profibus DP interface module.

5136-DNP-VME: DeviceNet interface module.

5136-SD-VME: Allen-Bradley Smart Device (Remote I/O) interface.

5136-CN-VME: ControlNet interface module.

Application Cases

Steel & Paper Mills: Coordinating high-speed drives in mills where Reliance Electric AutoMax systems are the legacy standard.

System Migration: Acting as a bridge to allow modern VME-based controllers to communicate with existing Reliance Electric remote I/O racks.

Data Logging: High-speed extraction of diagnostic data from R-Net networks for third-party SCADA systems.

Automotive Assembly: Managing synchronized conveyor systems and robotic cells utilizing Reliance hardware.

Product Advantages and Features

Protocol Offloading: The onboard processor manages the entire Reliance R-Net stack, preventing the VME host CPU from becoming a bottleneck.

Deterministic Timing: Guaranteed scan times required for precision tension control and high-speed web processing.

Direct Memory Mapping: The 512 KB shared RAM allows the VME host to read/write network data as if it were local memory, maximizing throughput.

Flash-Based Firmware: Supports easy field updates to accommodate different Reliance protocol versions or custom functional requirements.

Ruggedized Design: Built specifically for the harsh electrical environments typical of heavy industrial manufacturing.

Installation and Maintenance

Installation

Addressing: Configure the VME base address via the onboard DIP switches before inserting the card.

Mounting: Carefully slide the 6U module into the VME rack. Tighten front-panel screws to ensure a solid ground connection.

Cabling: Use high-quality shielded twisted-pair cable for the R-Net connection. Ensure the network is properly terminated at both ends.

REXROTHDDS2.1W200-D
REXROTHCSH01.1C-SE-EN2-NNN-NNN-NN-S-XP-FW
REXROTHR901325866+R900775346+R901273425A
RexrothBGR   DKC02.3-LK SCK02/01
REXROTHMKD025B-144-KG1-UN
REXROTHBTV04.2GN-FW
REXROTHSYHNC100-NIB-2X/W-24-P-D-E23-A012
REXROTH4WE6Y62/EG24N9K4   R900561276 + HSZ10-26916-AA/G24N9K4M01 R901025684
REXROTH4WRSE10V80-32/G24K0/A1V-695   R900247749 R900842748-K
REXROTHMHD095C-058-NG1-RN
REXROTHSYHNC100-NIB-23/W-08-P-D-E23-A012
REXROTHVT-HNC100-1-22/W-08-0-0
REXROTHVT-HNC100-1-23/M-08-P-0
REXROTHVT-HNC100-1-23/W-08-S-0
REXROTHVT3024
RexrothMHD041B-144-PG1-UN
REXROTHMSK060C-0600-NN-S1-UP1-NNNN
REXROTHVT-HNC100-1-22/W-08-C-0
REXROTHMHD093C-058-PG1-AA
Rexroth0608820116

Maintenance

Status LEDs: Monitor the "SYS" (System) and "NET" (Network) LEDs. A solid green light indicates normal operation; flashing red typically indicates a configuration mismatch or cable fault.

Airflow: Ensure the VME rack's fan assembly is operational, as the high-density components on the 5136-RE-VME generate significant heat during continuous operation.

Backup: Maintain a copy of the binary configuration files used to initialize the card via the host software.

Unique Product Description

The SST 5136-RE-VME is the "Missing Link" for facilities running Reliance Electric infrastructure.

While many communication cards require complex driver overhead, the 5136-RE-VME uses a Dual-Port RAM architecture that simplifies the interface for the programmer.

It effectively treats the entire Reliance R-Net network as a block of local VME memory, making it the most efficient solution for real-time control and high-speed data acquisition in specialized industrial environments.



  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output