KONG -Y
NameDescriptionContent
Location:
product
Woodward  easY-I-3400XT-P1  8440-2293
❤ Add to collection

Woodward easY-I-3400XT-P1 8440-2293

Woodward  easY-I-3400XT-P1  8440-2293

U.S.$54330.00
U.S.$53660.00
U.S.$50977.00
U.S.$49903.80
Weight:1.290KG
Quantity:
(Inventory: 1)
Buy now
Add to cart
Description

Woodward  easY-I-3400XT-P1  8440-2293


Woodward  easY-I-3400XT-P1  8440-2293

Output Type/Preset Description

Relay output [R 10] Programmable

Fixed to"Command: close GGB" if GGB is

activated otherwise preconfigured to "Aux

iliary services"

Only applicable for application mode ,  and .

The discrete output "Command: close GGB" is an impulse output

signal.

This discrete output is enabled for the time configured in param

eter 5726 Ä p. 223.

An external holding coil and sealing contacts must be utilized with

the GGB closing circuit.

Preconfiguration "Auxiliary services":

The auxiliary services output (LogicsManager 03.01) will be ena

bled with the start command (prior to the engine start because of

the prerun time) and remains enabled as long as the engine is

running.

It will be disabled after the engine has stopped and the postrun

time has expired(i.e. for operating a cooling pump). Ä “Auxiliary

operations” on page 165 for this behavior.

The auxiliary services output (LogicsManager 03.01) is always

enabled in MANUAL operation mode.

Relay output [R 11] Programmable

Fixed to"Command: open GGB" if GGB is

activated otherwise preconfigured to

"Alarm class A and B"

Only applicable for application mode ,  and .

The controller enables this discrete output when the GGB is to be

opened for switching operations.

If the discrete input "Reply GGB" is energized, the discrete output

"Command: open GGB" is disabled.

Preconfiguration "Alarm class A and B":

This discrete output is enabled when a warning alarm (class A or

B alarm) is issued ( Ä Chapter 9.5.1 “Alarm Classes”

on page 944).

After all warning alarms have been acknowledged, this discrete

output will disable.

Relay output [R 12] Programmable

Preconfigured to "Shutdown alarm"

This discrete output is enabled when a shutdown alarm (class C

or higher alarm; refer to Ä Chapter 9.5.1 “Alarm Classes”

on page 944 for more information) is issued.

After all shutdown alarms have been acknowledged, this discrete

output will disable.

LogicsManager

Relay

All discrete outputs not assigned to a defined function, may be

freely configured via the LogicsManager.

Discrete Inputs

Discrete inputs may be configured to normally open (N.O.) or nor

mally closed (N.C.) states.

Fig. 150: Discrete inputs - alarm/control inputs - operation logic

(state N.O.)

In the state N.O.:

n No potential is present during normal operation.

n If an alarm is issued or control operati888on is performed, the

input is energized.

Fig. 151: Discrete inputs - alarm/control inputs - operation logic

(state N.C.

In the state N.C.:

n A potential is continuously present during normal operation

n If an alarm is issued or control operation is performed, the input

is de-energized.

ID Parameter CL Setting range

[Default]

Description

1200 DI {x} Delay 2 0.08 to 650.00 s

[0.20 s]

A delay time in seconds can be assigned to each alarm or control input.

The discrete input must be enabled without interruption for the delay time

before the unit reacts.

If the discrete input is used within the LogicsManager this delay is taken into

account as well.

1201 DI {x} Opera

tion

2 The discrete inputs may be operated by an normally open (N.O.) or normally

closed (N.C.) contact.

The idle circuit current input can be used to monitor for a wire break.

A positive or negative voltage polarity referred to the reference point of the DI

may be applied.

[N.O.] The discrete input is analyzed as "enabled" by energizing the input (normally

open).

N.C. The discrete input is analyzed as "enabled" by de-energizing the input (nor

mally closed).

1202 DI {x} Alarm

class

2 An alarm class may be assigned to the discrete input.

The alarm class is executed when the discrete input is enabled.

A/[B] Warning alarm classes

C/D/E/F Shutdown alarm classes

Control Signal to issue a control command only.

If "control" has been configured, there will be no entry in the event history and

a function out of the LogicsManager ( Ä Chapter 9.3.1 “LogicsManager Over

view” on page 860) can be assigned to the discrete input.

1204 DI {x} Self

acknowledge

2 Yes The control automatically clears the alarm if the fault condition is no longer

detected.

[No] The control does not automatically reset the alarm when the fault condition is

no longer detected.

The alarm must be acknowledged and reset by manually pressing the appro

priate buttons or by activating the LogicsManager output "External acknowl

edgment" (via a discrete input or via an interface).

Notes

If the DI is configured with the alarm class "Control", self acknowledgment is

always active.

1203 DI {x} Enabled 2 87.70 LM:

Eng.mon

Monitoring for fault conditions is not performed until engine delayed moni

toring is enabled. The engine monitoring delay time (param

eter 3315 Ä p. 167) must expire prior to fault monitoring being enabled for

parameters assigned this delay.

[Always] Monitoring for this fault condition is continuously enabled regardless of engine

speed

GEV7768-320000   350-9301007768-320000 A0
GEIS220PDOAH1A
GEIC698CPE020-CC
GEIS420ESWBH3A
GEIS200TPROH1BCB
GEIC695CRU320CA-EL
GEIS215UCVEM09A   VMIVME-017614-132 VMIVME-7698
GEIC698CMX016   VMIVME-5567-000 350-005567-000
GEVMIVME-7455
GEVMIVME-2128
GEIS220PDIAH1A   336A4940CSP1
GEIS230SNRTH2A
GEIS220PRTDH1BC   336A5026ADP13
GEIS220PAICH2A   336A4940CSP11
GEIC200PWR101D
GEF650-G-N-A-B-F-2-G-1-HI-C-E
GEIS200AEPCH1BAA



  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software