Valmet A413015 NCU (network control unit) is a key communication component in the Valmet automation control system, which is specially designed for efficient data exchange and equipment integration in industrial environment. The following is a detailed description of its technical characteristics and application scenarios:
1. Core functions
Industrial communication hub
As a network control unit (NCU), A413015 is responsible for establishing real-time data channels among PLC, sensors, actuators and other field devices, supporting various industrial protocols (such as PROFIBUS, EtherNet/IP or CC-Link IE TSN) to ensure seamless integration of the system.
Modular compatibility
It can work with Valmet modular PLC system (such as CPU module and I/O module), adapt to multi-CPU architecture environment, and meet the needs of division of labor for complex tasks.
High reliability design
Industrial-grade hardware (such as anti-interference circuit board design and wide temperature operation range) is adopted, which is suitable for harsh environment (such as factory workshop or process control site).
2. Technical parameters (example)
Communication interface:
Dual Ethernet ports (supporting TSN time-sensitive network)
Optional PROFIBUS-DP or RS-485 serial interface.
Protocol support: OPC UA, Modbus TCP/IP, etc.
Installation method: DIN guide rail installation or panel fixing.
Operating temperature:-20 C to+60 C.
3. Typical application scenarios
Factory automation
The robot controller (such as motion CPU supporting multi-axis interpolation) and the vision system are connected in the production line to realize real-time data synchronization.
process control
As the gateway of distributed I/O system, it collects the data of temperature controller (such as multi-loop PID module) to the central DCS.
remote monitoring
Upload the data of edge devices to the cloud or SCADA system through OPC UA protocol to support predictive maintenance.
4. Advantages of integration with Valmet system
Extensibility: It can be matched with Valmet's FA-M3V or e-RT3 Plus controller to support the addition of secure CPU or AI inference module in the future.
Programming flexibility: If NCU integrates lightweight runtime (such as CODESYS), users are allowed to customize communication logic.
5. Maintenance and diagnosis
Status indicator: it can directly display the network status, power supply and fault code (such as ERR 413).
Tool support: configure parameters or diagnose packet loss through Valmet engineering software (such as Automation Studio).
User name | Member Level | Quantity | Specification | Purchase Date |
---|
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com