KONG -Y
NameDescriptionContent
Location:
product
ABB SPTPS02 Turbine Protection Slave Module
❤ Add to collection

ABB SPTPS02 Turbine Protection Slave Module

SPTPS02 Turbine Protection Slave Module
U.S.$11692.00
U.S.$7002.00
U.S.$6651.90
U.S.$6511.86
Weight:2.130KG
Quantity:
(Inventory: 10)
Buy now
Add to cart
Description
SPTPS02 Turbine Protection Slave Module

Symphony Plus Turbine Protection Slave Module

The installation procedure utilizes the industry standard Install shield Setup program. Do the following procedure to install OPC90. This procedure assumes that the OPC90 Server is being installed on a Windows XP / 2003 Server / Windows 7 /10 / 2008 / 2012 / 2016 / 2019 / 2022 Server operating system.

1.) Log into a user account with administrator privilege.

2.) Insert the OPC90 Server installation CD into the CD drive.

3.) Run the setup program found in the root directory of the CD.

a. Right click on it and select Run as Administrator.

4.) Follow the instructions given by the Setup program.

5.) If using hardware licensing insert the RoviSys USB license key.

6.) If using software licensing run the RoviSys License Manager program and request a license. Until the license activation code is received setup a couple day demo period.

7.) You have completed installation of OPC90 Server!

After installation on Windows 7 right click on the C:Program FilesOPC90 ServerOPC90Server.exe file, select properties and set compatibility mode to Windows XP. This will allow OPC90 to run as a service under Windows 7 and communicate with SCSI CIUs.

When upgrading, first uninstall using Windows add/remove programs and then run the above procedure. If running OPC90 as a service, make sure it is stopped before uninstalling.

Note that the demo version of OPC90 downloaded from the RoviSys website does not support software licensing. It must be uninstalled and the official version installed using the installer sent by RoviSys when a software license is purchased.

Bailey Communication OverviewBailey Communication Overview Bailey Communication OverviewBailey Communication Overview Bailey Communication OverviewBailey Communication OverviewBailey Communication OverviewBailey Communication OverviewBailey Communication OverviewBailey Communication OverviewBailey Communication OverviewBailey Communication Overview Bailey Communication OverviewBailey Communication OverviewBailey Communication OverviewBailey Communication OverviewBailey Communication Overview Bailey Communication OverviewBailey Communication Overview Bailey Communication Overview

Bailey utilizes a communication technique for data exchange called exception reporting. Exception reporting means the data is sent when it has changed significantly or a maximum time has expired since the last time it was sent. All exception reported data is made available to the rest of the system via a set of exception report related function blocks which are matched by an equivalent OPC90 Server block. Bailey has a series of RS232 serial based devices generically called Computer Interface Units that are utilized to receive this exception report data. Note that communication with the INICI03 interface can be either RS232 or SCSI. RoviSys is extremely knowledgeable on the use of the various Bailey interfaces and has implemented a single driver that can utilize the following types of interfaces:

NSPM01 

IMSPM01

IMCPM02

When using these interfaces, the ABB Bailey semAPI software environment is not required. The INICI12, INIC13, and INICI03 do not support dual channel serial communication. When using serial communication to the INICI12, INICI13 and INICI03, make sure the cable is attached to the port labeled “terminal” on the ABB Bailey termination unit or termination module. See the sections “Add”

OPC90 Server User Manual V8.9.2

RoviSys Company Copyright © 1999-2023 Page | 10

and “Device Definition Block” for information regarding SCSI communication with the INICI03.

a. INICI03 sites containing INICT03A firmware revision ‘F’ must upgrade to revision ‘G’ or later or downgrade to revision ‘E’.

b. INICI13 is comprised of the INICT13A and INNIS01 modules. The default factory settings for the INICT13A SW4 are incorrect. The INICT13A SW4 Poles 6, 7, 8 must be open (1) when using SCSI with this module.

2.) OPC90 supports Ethernet communication with PNI800. PNI800 firmware revision A7 and A8 has been tested with OPC90 but earlier versions might also work. See "Using OPC90 with PNI800” section for details on setting it up.

3.) OPC90 supports Ethernet or serial communication with IET800. IET800 firmware revision A7 or later is required for Ethernet communication. See “Using OPC90 with IET800” section for details on setting it up.

Throughput of the supported Bailey CIU devices is difficult to calculate empirically since the data is received and sent by exception and varies according to the total blocks in the database, data types of those blocks and what has changed significantly at any given time. The exception report rate per general data type for RS232 and SCSI interfaces presented in following table. The Ethernet style CIU is 2-3 times faster than SCSI.

  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software
  • Bently 2300/20 and 2300/25 2300 Vibration Monitors
  • ABB NGC8206 Natural Gas Chromatograph Dual Unit
  • MOTOROLA MVME2400 TM VME Processor Modules
  • 5320 Series Foxboro DCS Control Network Ethernet Equipment
  • ExtremeSwitching™ 5420 Series
  • WOODWARD EGCP-3 Engine Generator Control Package LS (Load Sharing)
  • 5520 Series Universal Edge/Aggregation-Switch Platform
  • X440-G2 Series
  • EMERSON FloBoss™ S600 Flow Manager Specification Sheet
  • KONGSBERG RAIV400 Remote Analogue Input, Voltage
  • RMP420-Remote Multipurpose Input/Output Kongsberg
  • 610 serie ABB Feeder Protection REF610 Product Guide
  • Triconex 3351S2 Controller Features
  • HBRF Megamax – Emax2 Air Circuit Breaker ABB
  • ABB MEASUREMENT & ANALYTICS | DATA SHEET LS4000 Diode laser analyzer
  • Pressductor Pillowblock Load Cells Vertical Measuring PFCL 201 User manual
  • PARKER BFR5K Series
  • AC 900F controller ABB
  • Uniop ePAD05 and ePAD06 Technical description
  • Hitachi ABB Communication Unit 560CMR02
  • MOTOROLA MVME5500 Series VME Single-Board Computer
  • ABB Symphony Plus SD Series HPC800 controller
  • ABB AC800M Controller Hardware System
  • ABB AC800M PROFIBUS DP Installation System
  • ABB Freelance 800F AC800F Control systems
  • ABB Compact control system replaces PLC AC700F
  • abb Triguard SC300E 3BNP004720R101 TMR Safety Products
  • ABB Distributed busbar protection REB500
  • ABB Advant Controller 400 series
  • ABB MEASUREMENT & ANALYTICS | PRODUCT GUIDE
  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-
  • 3BHB007441P0001 LDSTA-01 ABB inverter control CPU driver board