SAUTER  AVM322S-R  Linear valve actuator AVM 234S series
❤ Add to collection

SAUTER AVM322S-R Linear valve actuator AVM 234S series

SAUTER  AVM322S-R  Linear valve actuator AVM 234S series

U.S.$11520.00
U.S.$9520.00
U.S.$9044.00
U.S.$8853.60
Weight:0.750KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Description

SAUTER  AVM322S-R  Linear valve actuator AVM 234S series




The cross-section of the power cable must be selected based on the cable length and the number of

actuators. With five parallel actuators and a cable length of 50 m, a cable cross-section of 1.5 mm2

and a line resistance of > 1.5 Ω must be used (power consumption of the actuator × 5).

According to building installation regulations, the lines must be protected from overload or short cir

cuit

Specific standards such as IEC/EN 61508. IEC/EN 61511. EN ISO13849 and the like have not been

taken into account.

Local requirements regarding installation, usage, access, access rights, accident prevention, safety,

dismantling and disposal must be taken into account.

Place of installation

The devices may only be used indoors.

It is not admissible to use them in the following locations:

• in outdoor areas

• in potentially explosive atmospheres

• on ships or in vehicles

• in plants or machines with required functional safety.

Additional information

Fitting instructions

Declaration on materials and the environment

Declaration of incorporation

Power consumption at nominal voltage

Type

Running time (s/mm)

P100011900

MD 51.375

P100012470

Status

AVM321S

12 / (4)

Active power P (W) Apparent power S (VA)

Operation < 1.7

Standstill < 0.45

< 3.5

−

Sizing

AVM322S

6 / (4)

−

Operation < 1.7

Standstill < 0.45

Sizing

Max. power consumption with accessory 0500570001

for all types

Connection as 2-point valve actuator (24 V)

24 V=

24 V~

−

5.2

6.2

≥ 4.5

< 3.5

−

≥ 4.5

−

11

The OPEN/CLOSE activation is via two wires.

The actuator is connected to a permanent voltage via terminal MM and terminal 01.

When voltage (24 V) is applied to terminal 02. the actuator spindle extends into the end position.

After the voltage is switched off at terminal 02. the actuator automatically retracts into the base posi

tion.

Terminal 03 must not be connected or touch other contacts. We recommend that you insulate these.

Connection as 3-point valve actuator (24 V)

If voltage is applied to terminals MM and 01 (or 02), the valve can be moved to any position.

If voltage is applied to terminals MM and 01. the actuator spindle retracts.

If the electrical circuit is closed on terminal MM and 02. the actuator spindle extends.

If there is no voltage on terminals 01 and 02. the actuator remains in the respective position until volt

age is applied again.

ABBREX615
ABB3BHS036290R0001 PA110358
WESTERMOTD-36 (485) 3618-0001
ABBMRW-6420P
HoneywellCC-PWRR01
GE345-E-P5-G5-H-E-M-N-N-1E-D-H
GESSF16Y216
GEVMIVME-7807
GEACC-5595-208
HoneywellFC-PSU-UNI2450U
ABBPP846 3BSE042238R1
ALSTOMAL129A
ALSTOMLC105A-2
ALSTOMLC106-1
CONVERTEAMP111-6052
Metso,ND9106FN
GEIS230JPDGH1B
Meggit200-510-071-113

Terminal 03 must not be connected or touch other contacts. We recommend that you insulate these.

Connection to a control voltage (0...10 V or 4...20 mA)

The built-in positioner controls the actuator depending on controller’s output signal y. A voltage signal

(0...10 V) at terminal 03 serves as the control signal. Coding switch S4 can be used to switch to a

current input (4...20 mA). If there is voltage on terminals MM/01 and a rising positioning signal, the

actuator spindle extends. The direction of operation can be reversed with coding switch S2.

The starting point and control span are fixed. For setting partial ranges (only for voltage input), a split

range unit is available as an accessory (see split-range unit function).

After the connection of the power supply and the initialisation, the actuator moves to every valve

stroke between 0% and 100%, depending on the control signal. Thanks to the electronics and the ab

solute distance measurement system, no stroke is lost, and the actuator does not require periodic re

initialisation.

If the control signal 0...10 V is interrupted in the direction of operation 1. the actuator spindle retracts

completely.

If the control signal 0...10 V is interrupted in the direction of operation 2. the actuator spindle extends

completely.

With coding switch S3. the characteristic of the valve/actuator combination can be adjusted. An

equal-percentage characteristic can only be generated when the actuator is used as a continuous ac

tuator.

Initialisation and feedback signal

The actuator initialises itself automatically when it is connected as a continuous actuator (not in 2-/3

point mode). With the first application of voltage the actuator moves until it reaches the mechanical

stop and connects to the valve.

For 8 mm travel range of AVM321SF132

After the actuator has stopped moving to connect to the valve, it moves to the upper first stop and

then to the 8 mm travel range in the opposite direction. If the valve travel range is greater than 8 mm,

the initialisation stops after 8 mm. The two values are recorded and stored by the absolute distance

measurement system. The control signal and the feedback are adapted to this effective stroke. If it

cannot move the 8 mm travel range, the initialisation is cancelled and the actuator indicates “Under

range”. After initialisation, the actuator goes to every valve stroke between 0% and 100%, depending

on the control voltage.

For 20 mm travel range of AVM322SF132

After the actuator has stopped moving to connect to the valve, it moves to the upper and lower stop.

The travel range thus achieved is recorded by the measurement system and apportioned as 0 to

100% travel range. The control signal and the feedback are adapted to this effective stroke.

In case of a power failure or the removal of the power supply, no re-initialisation needs to be carried

out. The values remain saved.

If the initialisation is interrupted, the initialisation restarts when the voltage is reapplied.

You trigger a re-initialisation by moving coding switch S8 from OFF to ON or vice versa.

When the process is triggered, the LED flashes green.

During initialisation, the feedback signal is inactive or equal to the value “0”. The initialisation is car

ried out with the shortest running time. The re-initialisation is only valid when the whole process is

complete.

If a stroke change is carried out, a re-initialisation must be triggered so that the new stroke can be

adapted.

If the valve actuator detects jamming, it will report this by setting the feedback signal to 0 V after

about 90 s. During this time, the actuator continues to try to overcome the jamming. If the jamming

can be overcome, the normal control function is activated again and the feedback signal is restored.

With 2-point or 3-point control without a feedback signal, no initialisation is performed.

Continuous control can also be implemented with a 230 V power supply with the external accessory

0500570003 “230 V module”. You must ensure that the neutral wire of the controller is connected to

the control voltage. The neutral wire of the power supply may only be used for the 230 V module


  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 XMx16 + XIO16T extended condition monitoring modules
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET