KONG -Y
NameDescriptionContent
Location:
product
OMRON C120-LK202-EV1/C120LK202EV1
❤ Add to collection

OMRON C120-LK202-EV1/C120LK202EV1

OMRON C120-LK202-EV1/C120LK202EV1

U.S.$9750.00
U.S.$8699.00
U.S.$8264.05
U.S.$8090.07
Weight:1.290KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Description

OMRON C120-LK202-EV1/C120LK202EV1




OMRON C120-LK202-EV1

CPU Capabilities

The C200H-CPU21-E/CPU23-E/CPU31-E CPUs are based on the C200H

CPU11-E CPU, except only the CPU31-E supports Network Instructions. All of

the CPUs covered in this manual also support a group of High-density I/O Units

called Group-2 High-density I/O Units. Group-2 High-density I/O Units are clas

sified by themselves and are not classified as Special I/O Units.

The following table lists the capabilities of the various C200H CPUs.

Function CPU01-E CPU03-E CPU11-E CPU21-E CPU23-E CPU31-E

Compatible with Group-2 High-density I/O Units

(C200H-ID216/ID217/OD218/OD219)

No No No Yes Yes Yes

Can process GROUP-2 HIGH-DENSITY I/O

REFRESH – MPRF(61)

No No No Yes Yes Yes

Compatible with C200H-MR433/MR833/ME432

Memory Units

Yes1 Yes1 Yes1 Yes Yes Yes1

Compatible with C200H-ME832 Memory Unit No No No Yes Yes Yes1

Error history No No Yes Yes Yes Yes

Clock/calendar No No Yes Yes2 Yes2 Yes

Forced Status Hold Bit (SR 25211) No No Yes Yes Yes Yes

Can set TERMINAL mode for Programming

Console

No No Yes Yes Yes Yes

Additional instructions:

REVERSIBLE WORD SHIFT – RWS(17)

CYCLE TIME – SCAN(18)

MULTI-WORD COMPARE – MCMP(19)

LONG MESSAGE – LMSG(47)

TERMINAL MODE – TERM(48)

SET SYSTEM – SET(49)

DOUBLE COMPARE – CMPL(60)

COLUMN-TO-WORD – CTW(63)

WORD-TO-COLUMN – WTC(64)

HOURS-TO-SECONDS – HTS(65)

SECONDS-TO-HOURS – STH(66)

VALUE CALCULATE – VCAL(69)

No No Yes Yes Yes Yes

Network Instructions:

NETWORK SEND – SEND(90)

NETWORK RECEIVE – RECV(98)

No No Yes No No Yes

Power Supply AC DC AC AC DC AC

Note 1.The C200H-CPU01-E/CPU03-E cannot use the Memory Units’ clock, and

the C200H-CPU11-E/CPU31-E CPUs have a built-in clock.

2.The C200H-CPU21-E/CPU23-E can use the C200H-MR433/MR833/

ME432/ME832 Memory Units’ clock.

Introduction

Details, including the name, acronym, range, and function of each area are sum

marized in the following table. All but the last three of these areas are data areas.

Data and memory areas are normally referred to by their acronyms.

Area Acronym Range Function

Internal Relay IR Words: 000 to 235

Bits: 0000 to 23515

Used to control I/O points, other bits, timers,

and counters, and to temporarily store data.

Special Relay SR Words: 236 to 255

Bits: 23600 to 25507

Contains system clocks, flags, control bits, and

status information.

Auxiliary Relay AR Words: AR 00 to AR 27

Bits: AR 00 to AR 2715

Contains flags and bits for special functions.

Retains status during power failure.

Data Memory DM Read/write: DM 0000 to DM 0999

Read only: DM 1000 to DM 1999

Used for internal data storage and manipula

tion.

Holding Relay HR Words: HR 00 to HR 99

Bits: HR 0000 to HR 9915

Used to store data and to retain the data values

when the power to the PC is turned off.

Timer/Counter TC TC 000 to TC 511 (TC numbers used

to access other information)

Used to define timers and counters, and to ac

cess completion flags, PV, and SV. In general,

when used as a bit operand, a TC number ac

cesses the completion flag for the timer or

counter defined using the TC number. When

used as a word operand, the TC number ac

cesses the present value of the timer or count

er.Link Relay LR Words: LR 00 to LR 63

Bits: LR 0000 to 6315

Available for use as work bits.

Temporary Relay TR TR 00 to TR 07 (bits only) Used to temporarily store and retrieve execu

tion conditions. These bits can only be used in

the Load and Output instructions. Storing and

retrieving execution conditions is necessary

when programming certain types of branching

ladder diagrams.

Program Memory UM UM: Depends on Memory Unit used. Contains the program executed by the CPU.

When some bits and words in certain data areas are not being used for their in

tended purpose, they can be used in programming as required to control other

bits. Words and bits available for use in this fashion are called work words and

work bits. Most, but not all, unused bits can be used as work bits. Those that can

be used are described area-by-area in the remainder of this section. Actual ap

plication of work bits and work words is described in Section 4 Writing and Input

ting the Program.

Some data areas contain flags and/or control bits. Flags are bits that are auto

matically turned ON and OFF to indicate particular operation status. Although

some flags can be turned ON and OFF by the user, most flags are read only; they

cannot be controlled directly.

Control bits are bits turned ON and OFF by the user to control specific aspects of

operation. Any bit given a name using the word bit rather than the word flag is a

control bit, e.g., Restart bits are control bits.



  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output