Carrier Ces0110074-01 circuit control board
CES0110074-00 and CES0110074-01 Differences: This board functions identically as the CES0110074-00 and the CES0110074-01. It is a form, fit and functional replacement of the CES0110074-01. When replacing the CES0110074-00 some quick connectors have to be changed or added. EAC-1 and EAC-2 must have 1/4” connectors. COM, SEC-1 and SEC-2 must have 3/16” connectors
NOTES: 1. Internally connected to equipment ground through mounting screw. 2. If any of the original equipment wire is replaced, use wire rated for 105°C. 3. Blower motor (BLWM) & inducer motor (IDM) contain auto-reset thermal overload switch. 4. Blower motor factory speed selections (PL4) are for average conditions. See installation instructions for details on optimum speed selections. 5. Use only copper wire between the disconnect switch and the furnace junction box (JB). 6. Symbols are electrical representations only 7. Auxiliary limit switch (ALS) used on down flow models only. 8. The transformer 24 VAC winding is protected by a 3 AMP automotive blade-type fuse on the control board. A 24 VAC short to ground during installation checkout, operation, service or maintenance could cause the fuse to open. Do not replace the 3 AMP fuse with any other size fuse. 9. Blower motor (BLWM) adjustable off-relay. Factory set, 120 seconds, cut resistor, 180 seconds.