Part Number DS200DTBBG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200DTBBG1A is a Terminal Board Digital Connector Card under Mark V series GE. The GE DS200DTBBG1A Terminal Digital Connector Board has two terminal blocks, each containing terminals for 95 signal wires. Three 50-pin connections are also included. JFF, JFG, and JFH are the IDs for the 40-pin connectors. There are also five jumpers and bayonet connectors. Because there are three 40-pin connectors on the board, it's crucial to keep track of which 40-pin ribbon wire is linked to which connector. It's critical to get the drive back in service after replacing the board if you want to regain productivity. If the ribbon cables are attached to the wrong connections, you must shut down the drive, relocate the ribbon wires to the correct connectors, then restart the drive. This can result in a loss of productivity and can annoy operators working on adjoining drives. There is the ability for up to 110 signal wires to be connected to the terminal blocks. Without a method to document where the different signal cables are attached, this will be difficult to manage. The ID for one terminal block is TB1, whereas the ID for the other terminal block is TB2. On each terminal block, the individual terminals are numbered in order. As a result, the terminal block ID and the number assigned to the terminal are used to identify a specific terminal. TB1 90 and TB2 48 are two examples. Terminal 90 on Terminal Block 1 is TB1 90. Terminal 48 on Terminal Block 2 is TB2 48.DS200DTBBG1A (GE Terminal Digital Connector Board) is part of the Mark V series which features two terminal blocks for 95 signal wires in each and contains three 50-pin connectors. JFF, JFG, and JFH are the IDs for the 40-pin connectors, and the board is also populated with bayonet connectors and It is important to track which 40-pin ribbon cable is connected to which connector since the board has three 40-pin connectors. If the wrong ribbon cables are connected to the wrong connectors, you will have to bring down the drive, correct the placement of ribbon cables to connectors and restart the drive. There is a chance you will see a loss in in mind, it is key to get the drive back in service to regain productivity after you restart the drive from replacing the board.There is potential for a maximum of 110 signal wires to be attached to the terminal blocks, but it can be difficult to manage without documenting where the separate signal wires are connected.
DS200DCFBG1BLC
MS90376-12Y
VMIVME-7807RC
SERVOSTAR 310
IS200ERIOH1AAA
IS220PSCAH1A 336A4940CSP9
D20-PS LFDSC143-4000
IS200TDBTH6ABC
DS200SHVMG1AGE
IS2020RKPSG3A
DS200SHVMG1AFE
IC660ELB912
IS220PPRFH1A
IC698PSA350
HYDRAN M2
IC693PWR321
IS215VCMIH2BB IS200VCMIH2BCC
User name | Member Level | Quantity | Specification | Purchase Date |
---|
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com
Website: https://www.abb-sis.com