DS200NATOG3A

Part Number DS200NATOG3A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200NATOG3A is a Voltage Feedback Scaling Board developed by GE under Drive Control. It is a specialized board designed for voltage feedback scaling in NATO applications. Its primary function is to attenuate both AC and DC voltages generated by an SCR (Silicon-Controlled Rectifier) bridge. By accurately reducing the voltage levels, the board enables precise derivation of bridge voltage feedbacks. The module operates in conjunction with two other essential boards: a VME backplane and a gate distribution and status board. The VME backplane serves as the backbone of the system, providing a standardized interface for multiple boards to communicate and share data efficiently. Meanwhile, the gate distribution and status board is responsible for controlling the gating signals of the SCR bridge, ensuring synchronized operation and monitoring the status of each gate. It serves as a central hub for managing the gate signals and receiving feedback from the board. Together, these three boards form a comprehensive system for controlling and monitoring the SCR bridge. Input The input section of the board is designed to accommodate different voltage levels and consists of five identical, series-connected strings of precision resistors. These resistor strings are responsible for attenuating the incoming voltages and ensuring accurate scaling for further processing. Each of the three AC phases (representing the three alternating current power lines) has its dedicated resistor string. Additionally, there are two more resistor strings, one for the positive DC bus voltage and another for the negative DC bus voltage. These resistor strings collectively handle the voltage feedback for the entire system. To configure each resistor string, the NATO board provides a selection of three different input stab connectors. These connectors allow the connection of the appropriate input voltage source to the resistor string. Additionally, two wire jumpers are available for further attenuation of the input voltage. The selection of input stab connectors and wire jumpers allows the user to adapt the board to various voltage ranges. The available voltage options for attenuation are 6900, 4200, 3300, 2200, or 1200 volts. By selecting the appropriate combination of connectors and jumpers, the user can set the desired attenuation level to match the specific voltage requirements of their application. It ensures that the voltage feedback derived from the resistor strings accurately represents the input voltages, enabling precise control and monitoring of the SCR bridge in the subsequent stages of the system. Output The output section of the board facilitates the connection of the five resistor strings to a single 20-pin ribbon header. This ribbon header serves as the output interface, allowing the derived voltage feedback from each string to be transmitted to other components or subsystems within the larger system. To ensure the safety and protection of the output circuit, each string is equipped with a metal oxide varistor (MOV). The MOV acts as a voltage-limiting device, preventing the output voltage of each string from becoming excessively high in case the output ribbon circuit is interrupted while the input voltage is still present. The MOV provides a level of overvoltage protection, safeguarding the connected components and preventing potential damage. It is important to note that the burden resistor, which is responsible for measuring the output voltage, is not located on the NATO itself. Instead, it is positioned on the gate distribution and status board. The burden resistor is connected to the output ribbon header and serves to measure the voltage levels accurately. By locating the burden resistor on the gate distribution and status board, rather than on the NATO board, it allows for more flexibility in system design and configuration. It enables the board to focus on its primary function of attenuating and scaling the input voltages accurately, while the gate distribution and status board handles the precise measurement of the output voltage using the burden resistor. This separation of responsibilities between the NATO board and the gate distribution and status board ensures efficient and optimized operation of the system as a whole, providing accurate voltage feedback while maintaining the necessary safety measures for the output circuit. Installlation Turn off power: Before beginning any installation or removal procedures, ensure that the power to the system is turned off. This precaution is crucial to prevent electrical accidents and damage to the equipment. Disconnect cables: Carefully disconnect all cables connected to the NATO board. The process may vary depending on the type of cable connectors: For ribbon cables without pull tabs: Place one hand on each side of the cable connector that mates with the board connector. Gently pull the cable connector with both hands to disconnect it from the board. For ribbon cables with pull tabs: Locate the pull tab on the cable connector. Carefully pull the tab to detach the cable from the board. Remove standoffs and lock washers: The NATO board is typically secured in place by standoffs and lock washers. Remove the standoffs using an appropriate tool, such as a screwdriver or wrench. Take caution not to drop the lock washers into the board or the unit, as this can cause damage. Remove the board: Keeping the NATO board level, carefully pull it straight out from its slot using both hands. Ensure that you maintain a firm grip on the board to prevent any accidental drops or damage. Install the new NATO board: Position the new NATO board in the empty slot, aligning it properly. Secure the board in place by reattaching the standoffs and lock washers. Ensure they are tightened securely but not excessively, as overtightening can lead to damage. Reconnect cables: Take each cable that was disconnected in step 2 and ensure that it is properly seated at both ends. Align the connector with the corresponding slot on the NATO board and firmly push it in until it is securely connected. Repeat this step for all cables, ensuring all connections are properly seated.NEXT GENERATION LCI

  • 81EU50 83SR50 88TK50 Universal I/O and control modules 丨ABB
  • GJR2390200R1411 83SR04R1411 Control Module Universal
  • ABB INSUMMCU2 MCU2A02V24 INSUM® PROFIBUS Gateway Manual SW 2.1
  • ABB REF542 series 1VCR007346 G0028 Function and configuration
  • ABB 216AB61 HESG324013R101 Control Panel-Specifications
  • ABB 216EA61B HESG448230R1/G
  • 216VC62A HESG324442R112/F 丨ABB
  • 500PSM03A 1MRB150038R1 series丨ABB Power control panel
  • REG216, CompactREC216 Numerical Generator ProtectionNumerical Control Unit
  • ABB Panel 800 series 3BSE092980R1 PP886 Standard Panel 15"
  • 500CIM05 1MRB150077R1/B ABB
  • 500CPU05 1MRB150081R1/E ABB-Module
  • 500SCM01 1MRB200059/C 1MRB15004R0001丨ABB Star coupler module
  • ABB SYNCHROTACT ® 5
  • ABB 3BHB006716R0277 SYN 5302a-Z,V277: Auto dual channel Syn
  • ABB Pressductor-PillowBlock Load cells series PFCL201
  • ABB UNS4684A-P,V.1 HIEE305114R00R0001 control panel
  • Tension Electronics PFEA 111, 112, 122 and 113 丨ABB
  • ABB PFRL101C-1.0KN 3BSE023316R1002 Web Tension Measurement
  • 1VCF750090804 HMI SUE 3000 (110...220 V) ABB
  • 57120001-AT DSAO 110 ABB
  • S100 I/O Modules DSAO 120 57120001-EY 丨ABB
  • Advant Controller 500 series 500BIO01 1MRB150005R0001 1MRB200060/E ABB
  • 3BHE023784R2530 PP D113 B01-25-111000: AC 800PEC Static Excitation Systems›UNITROL 6000 X-power
  • ABB EXC3BSE008105R1 SC560 Exchange
  • HR Series Turbine control systems SD Series remote I/O ABB
  • HR Series (Harmony Rack) I/O RSPASI23
  • ABB SPBRC400 Controller with Expanded Memory
  • E3HAB8101-18 Modules Drive System 丨ABB
  • ABB 3BHL000986P7000 LXN 1604-6, 27V 500W
  • ABB REF615_series_ Feeder protection and control
  • ACS 6000 series Medium voltage AC drives for control of 3–27 MW motors up to 3.3 kV
  • I/O Systems - S800 I/O series-ABB
  • SPAJ 140 C Series ABB
  • INCLUDING PFSK 113 7625013-S 丨ABB
  • AC 800PEC The high-performance control system for model-based design
  • HKQCS PARTS ON LINE 129740-002 ABB
  • UNITROL 6000 X-power 3BH022294R0103 GFD233A103
  • AO810 AO810V2 - ABB Ability™ System 800xA® hardware
  • Elastimold® molded vacuum reclosers – MVR MVR 0.44-10KA
  • AC 800M series PM865 3BSE030193R1 discontinued products
  • 1MRK000838-HA ABB RXIDK 2H series
  • ABB 605 series
  • Feeder protection REJ601 BD446NN1XG
  • ABB SAFT183VMC expansion module board unit specifications
  • 3BHB004661R0101 KU C711 AE; GATE UNIT POWER S GUSP
  • PRC3BSE066490R1 PM856AK01 Processor Unit
  • SM560-S (1SAP280000R0001) AC500 CPU Firmware SM560-S-FD-4
  • 769137 Detector 13CO2 10% (Uras26) ABB control unit
  • AC500 CPU Firmware
  • 0002-07-2-00001-01 BMXS Science Module (ADC)
  • Safety instructions for AC500 PLCs 3ADR025003M9903
  • ABB I/O Systems - S800 I/O AI830A
  • AC500-eCo PM556-TP-ETH; PLC-eCo CPU PM556-TP-ETH 3ABD00034186
  • ABB I/O Remote Unit ICSF08D1 CS31 CS 31 Procontic FPR3323101R1012-L
  • WMDOLT2-A75(65KA)6E 1TGE106812P0001 System circuit breaker Drawer type
  • Technical analysis of ABB 1MRK002247-Apr04 protection relay module
  • PFTL101A 0.5KN 3BSE004160R1 Pressductor PillowBlock horizontal load cell
  • 3BSE004166R1 PFTL 101A-1.0kN, Load cell
  • SD Series I/O Interface cRBX01 2VAA008424R1
  • ABB 3BSC950193R1 TB850 CEX-Bus Terminator
  • LDGRB-01 3BSE013177R1 Analysis of module technology
  • GRBTU 3BSE013175R1 Communication gateway module
  • 3BHE037864R0101P UF C911 B101: CVMI2B -PROGRAMMED-
  • Panel 800 version 6
  • 3BHE024577R0101 PPC907BE ACS 2000 Drive Manuals
  • I/O Systems - 3BSE028602R1 DO880 - ABB Ability™ System
  • ABB YPP110A 3ASD573001A1 application controller
  • 57520001-FY DSCS 150 GCOM Communication Unit
  • AC 800M - Processor Modules 3BSE018157R1 PM861AK01 Processor Unit
  • 3BSE069274R1 PP877K Key Panel 10.4" Panel 800
  • 3BSE069449R1 (CI854BK01) PROFIBUS DP-V1
  • 3BSE018135R3 CI858 ABB Ability System 800xA
  • P3BSE042238R1 PANEL 800-PP846 PRE-OWNED
  • ABB NDBU-95 NDBU - DDCS branching unit
  • X10-14210201 605-A53842-002 Abaco Systems specification
  • HIMax®System Bus Module X-SB01 Manual
  • GE Intelligent PlatformsVersaMax* PLC User Manual 151X1235DB15SA03
  • MOTOROLA FLN3524/FCN6650 adapter power supply
  • SYMAP ECG Ship Monitoring And Control Panel 12-36V DC
  • 9200 and 74712 Seismoprobe Velocity Transducers
  • 3500/91 EGD Communication Gateway Module 161204-01
  • 1900/55 Fan Monitor: Operation Manual
  • 3701/55 ADAPT (ESD) Emergency Shutdown Device 323174-01
  • 3300 XL 8 mmProximity Transducer System 330104-00-05-10-02-CN
  • MR series (Melody rack) input and output›CAC 10-P 3BDH000610R1
  • 57160001-ADF DSDP 170 inc. Pos. and Speed meas.
  • S100 I/O - Modules DSDO 115K12 Digital Outp, 32 ch, 24
  • AC 400 Power SA168K16 Basic Power Supply and Switch
  • 3BSE018290R1 DSAI 133A Analog Input Board 32 Channels
  • 3BSE011180R1 Advant Controller 450 Version 2.3 PM511V08 Processor Module
  • 3BSC950164R30 S100 I/O Cables DSTK 221L3 Cable Assembly ,Ribbon Cable,
  • 3BSE020419R1 S100 I/O - Modules DSAO 120AK01 Analog Output 8 ch 12 Bit,
  • REF3BSE012545R1 CI546 VIP Communication Interface
  • 3BSE004772R1 Advant Controller 410 Version 1.5 Communication Modules
  • AC 400 - Communication Modules 3BSE018283R1 CI522A
  • Bently Nevada 3500/05-01-03-00-00-00 Rack Module
  • 3500 Series Status System Bently Nevada 135473-01 Vibration Monitoring Module
  • 330130-045-00-00 Bently Nevada 3300 XL Extension Cable
  • Bently Nevada 330100-90-01 3300 XL 8 mmProximity Transducer System
  • Bently Nevada 149369-01 Key components of 3500 mechanical protection system
  • 106M1081-01 Universal AC Power Input Module Description
  • PR6423 8mm Eddy Current Sensor
  • PR6424 16mm Eddy Current Sensor
  • VIBRO-METER 200-560-000-112 Communication board
  • VIBRO-METER 200-510-111-035 Mechanical protection card
  • Bently Nevada 22810-01-05-50-02 Stop production status confirmation
  • 330180-91-05 Bently Nevada 5/8 mm Proximitor Sensor
  • HIEE300690R0001 AR C093 AE01 Relay Output Card
  • Multilin UR Family Proven, State-of-the-Art Protection & Control Systems
  • Multilin 8 Series Innovative protection and control relay platform
  • Multilin 3 Series Intuitive industrial and utility protective relays for feeders, motors and transformers
  • MVME177P TM Single-Board Computer MOTOROLA
  • ABB DRIVE SERVICES Spare Parts Service product description
  • Cradlepoint IBR200 Product life cycle announcement
  • CC PUIO3 series Honeywell CC-PAOH01 analog output module
  • Honeywell TC-OAV081 Analog output module p/n 97062778
  • Honeywell TC-PRR021 Redundant module DHL, UPS fast delivery
  • Honeywell TC-FXX102 TC-FX10210 controller
  • Honeywell TK-PRS021 C200 Product overview
  • Honeywell ML6420A3007-E master controller
  • Parts on HONEYWELL automaton S4560M S4560M1036 boiler-Diesel boiler
  • Honeywell PK 81181 Installation Instructions for the
  • Honeywell 2MLR-CPUH/F-CC MasterLogic-200 Specifications and Technical Data
  • 3BSE018161R1 PM864AK01 Processor Unit ABB
  • ABB 3BHE017628R0102 PPD115A102 club.
  • FANUC WHEDCO 78004655 System controller module
  • FANUC WHEDCO 78004661 Analysis I/O module