KONG -Y
NameDescriptionContent
Location:
product
DS200NATOG3A Manufacturer General Electric Country
❤ Add to collection

DS200NATOG3A Manufacturer General Electric Country

DS200NATOG3A
U.S.$84921.00
U.S.$61789.00
U.S.$58699.55
U.S.$57463.77
Weight:8.990KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
DS200NATOG3A

Part Number DS200NATOG3A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200NATOG3A is a Voltage Feedback Scaling Board developed by GE under Drive Control. It is a specialized board designed for voltage feedback scaling in NATO applications. Its primary function is to attenuate both AC and DC voltages generated by an SCR (Silicon-Controlled Rectifier) bridge. By accurately reducing the voltage levels, the board enables precise derivation of bridge voltage feedbacks. The module operates in conjunction with two other essential boards: a VME backplane and a gate distribution and status board. The VME backplane serves as the backbone of the system, providing a standardized interface for multiple boards to communicate and share data efficiently. Meanwhile, the gate distribution and status board is responsible for controlling the gating signals of the SCR bridge, ensuring synchronized operation and monitoring the status of each gate. It serves as a central hub for managing the gate signals and receiving feedback from the board. Together, these three boards form a comprehensive system for controlling and monitoring the SCR bridge. Input The input section of the board is designed to accommodate different voltage levels and consists of five identical, series-connected strings of precision resistors. These resistor strings are responsible for attenuating the incoming voltages and ensuring accurate scaling for further processing. Each of the three AC phases (representing the three alternating current power lines) has its dedicated resistor string. Additionally, there are two more resistor strings, one for the positive DC bus voltage and another for the negative DC bus voltage. These resistor strings collectively handle the voltage feedback for the entire system. To configure each resistor string, the NATO board provides a selection of three different input stab connectors. These connectors allow the connection of the appropriate input voltage source to the resistor string. Additionally, two wire jumpers are available for further attenuation of the input voltage. The selection of input stab connectors and wire jumpers allows the user to adapt the board to various voltage ranges. The available voltage options for attenuation are 6900, 4200, 3300, 2200, or 1200 volts. By selecting the appropriate combination of connectors and jumpers, the user can set the desired attenuation level to match the specific voltage requirements of their application. It ensures that the voltage feedback derived from the resistor strings accurately represents the input voltages, enabling precise control and monitoring of the SCR bridge in the subsequent stages of the system. Output The output section of the board facilitates the connection of the five resistor strings to a single 20-pin ribbon header. This ribbon header serves as the output interface, allowing the derived voltage feedback from each string to be transmitted to other components or subsystems within the larger system. To ensure the safety and protection of the output circuit, each string is equipped with a metal oxide varistor (MOV). The MOV acts as a voltage-limiting device, preventing the output voltage of each string from becoming excessively high in case the output ribbon circuit is interrupted while the input voltage is still present. The MOV provides a level of overvoltage protection, safeguarding the connected components and preventing potential damage. It is important to note that the burden resistor, which is responsible for measuring the output voltage, is not located on the NATO itself. Instead, it is positioned on the gate distribution and status board. The burden resistor is connected to the output ribbon header and serves to measure the voltage levels accurately. By locating the burden resistor on the gate distribution and status board, rather than on the NATO board, it allows for more flexibility in system design and configuration. It enables the board to focus on its primary function of attenuating and scaling the input voltages accurately, while the gate distribution and status board handles the precise measurement of the output voltage using the burden resistor. This separation of responsibilities between the NATO board and the gate distribution and status board ensures efficient and optimized operation of the system as a whole, providing accurate voltage feedback while maintaining the necessary safety measures for the output circuit. Installlation Turn off power: Before beginning any installation or removal procedures, ensure that the power to the system is turned off. This precaution is crucial to prevent electrical accidents and damage to the equipment. Disconnect cables: Carefully disconnect all cables connected to the NATO board. The process may vary depending on the type of cable connectors: For ribbon cables without pull tabs: Place one hand on each side of the cable connector that mates with the board connector. Gently pull the cable connector with both hands to disconnect it from the board. For ribbon cables with pull tabs: Locate the pull tab on the cable connector. Carefully pull the tab to detach the cable from the board. Remove standoffs and lock washers: The NATO board is typically secured in place by standoffs and lock washers. Remove the standoffs using an appropriate tool, such as a screwdriver or wrench. Take caution not to drop the lock washers into the board or the unit, as this can cause damage. Remove the board: Keeping the NATO board level, carefully pull it straight out from its slot using both hands. Ensure that you maintain a firm grip on the board to prevent any accidental drops or damage. Install the new NATO board: Position the new NATO board in the empty slot, aligning it properly. Secure the board in place by reattaching the standoffs and lock washers. Ensure they are tightened securely but not excessively, as overtightening can lead to damage. Reconnect cables: Take each cable that was disconnected in step 2 and ensure that it is properly seated at both ends. Align the connector with the corresponding slot on the NATO board and firmly push it in until it is securely connected. Repeat this step for all cables, ensuring all connections are properly seated.NEXT GENERATION LCI

  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-
  • 3BHB007441P0001 LDSTA-01 ABB inverter control CPU driver board
  • ABB LD series LDMTR-01 63940135F I/O module
  • ABB 7525A38G01 SCV-MR 600:5 7525A38
  • ABB C86-94639 Sensor Module Assembly,PCBA,TUV
  • Melcher W Series 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters Convert Select LWN2660-6E-G
  • ABB NDBU-95C; Star connection branching unit (9 outputs= 9 pcs 10 Mb)
  • ABB A2C 250 TMF 250-2500 4p F F 1SDA066792R1
  • ABB YC E1.2..E6.2-XT7M 220-240 VAC/DC 1SDA073687R1
  • ABB Electromagnetic flowmeter WaterMaster
  • ABB Model: S-PKZ2, ZM-25 -8- PKZ2,ZM-16-PKZ2,PS201PRE ,PKZMO-10-T
  • ABB 3BHE004385R0001 UNS 0884a, V1:Current Sensor 2000A
  • ABB 3AXD50000182992 ZCU-14 PACKED SP; CONTROL UNIT
  • ABB INDUSTRIALDRIVES UCU-22, UCU-23 andUCU-24control units
  • ABB LDMU series LDMUI-01 61320946C Overview of interface module
  • ABB HIEE410506P104 UAC389 Processor module
  • ABB BN5930.48 24VDC safety relay
  • ABB 3BHE006373R0101 XVC769 AE101 PC board
  • ABB 58967441 NTAC-02; PULSE ENCODER INTERFACE
  • ABB NEMA full voltage power devices
  • ABB 800xA Device Management and Fieldbus Overview
  • ABB FOUNDATION™ Fieldbus Linking Device LD 810HSE Ex V1.0
  • ABB 3BSE017235R1 PXAH 401 Operator unit
  • ABB Drives series SCYC51213 63911607C DRIVER BOARD
  • SCYC51220 63901075C ABB control panel
  • ABB HL000986P0006 High density digital input/output module
  • 3BHB004791R0101 ABB medium voltage drive ACS2000 series
  • ABB 3BHB009175R0001丨3BHB005922R0001 UNS 0880a-P,V1:CIN PCB completed
  • MTA025 EBG92026 ABB MTA series current transformers
  • ABB AF400-30-11-70 1SFL577001R7011
  • ABB 12556917-738385 RADOX GKW cable
  • ABB THYRISTOR MODUL WE-73-10/CH 64421956
  • ABB 969.105EBG 540KKS166899 automatic system
  • ABB CH-3185 3BHL000986P1006 Abbability 800xa automation system
  • ABB 500CMP04 HE401314/0001 1MRB150051R1 power-supply module
  • ABB 500TTM02 1MB150021R01161HF930712X010 control panel
  • ABB 500MBA01 1MRB150003R0002 1MRB200053/L operation manual
  • ABB 500MBA02 1MRB150003R000/B Safety rules
  • ABB 500MBA02 1MRB150003R0003 1MRB200053/M Full range of power modules
  • ABB AC 800PEC system 3BHE023784R1023 PP D113 B01-10-150000
  • ABB 4LA41100102V1.2 KB2 Display Unit
  • ABB 60 - 65 A perfect fit
  • ABB PPD113 B03-23-100110 3BHE023584R2334 AC800PEC Control Systems
  • ABB 3BHE028122R0001 XFD213A control panel
  • ABB 3BSE030220R1 CI854AK01 PROFIBUS-DP/V1 interface
  • AO845A ABB Ability™ System 800xA® hardware selector
  • ABB 64666606 DSMB-02C control panel
  • ABB 68444161 IGBT FS450R12KE3/AGDR-71C
  • ABB CTB810 HN800/CW800 Communications Terminal Board connects to LEFT side of MB810
  • ABB Ability™ Symphony® Plus SD Series controller HPC800
  • ABB 3BSE018293R1 DSAO-120A Analog Output Board 8 Channels
  • ABB REA101-AAA ARC PROTECTION
  • ABB 3BSC950262R1 TK851V010 Connection Cable, 1m
  • ABB I/O Systems - S800 I/O DI810
  • SOE - Infi 90 Series INSEM01 | ABB - DCS Center
  • ABB 3BSE010535R1 PM645B Processor Module
  • ABB Tension Electronics PFEA 111, 112, 122 and 113 User Manual
  • ABB 3HNA018564-001 DSQC355B/ANALOG IO
  • ABB 3BSE020512R2 AI801-eA S800 I/O Systems
  • ABB HIEE200130R0002 AF C094 AE02 ARCnet control panel
  • AC800M series HIEE300885R1 PPC380AE01 ABB
  • ABB SNAT604IFS REV.B code: 61029052 5761861-2B control panel
  • AC 800M - Controller Hardware - ABB
  • CP430 Installation and Operation Manual ABB,1SBC159103M0202
  • ABB 3BSE000355R1 DSPU 131 MA200 Interface Board
  • ICSI16E1 | ABB Procontic CS 31 Input Module Binary
  • MSR04X1 Wiring Accessories | Service and tools | ABB - ABB Group
  • EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X2-AB-DHRIO
  • Protection Cards for AMS 6500 Classic Systems EMERSON
  • EMERSON AMS Trex™ Device Communicator
  • EMERSON AMS 2140 Machinery Health™ Analyzer
  • EMERSON CSI 2140 Machinery Health Analyzer
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB GJR2391500R1210 81EU01H-E / 81EU01 Input Module universal
  • AC31 mit AC1131 Teil 16: Systemtechnik Serie 40/50
  • ABB IEPAS02 POWER MODULE +5, +/-15, 24
  • ABB 5SHX0660F0001 Asymmetric Thyristor IGCT series
  • ABB HIER464920P0001 CURRENT RELAY,UNS 0017A-P
  • ABB 3AFA408368 IMA MODULE
  • ABB SWISS MADE 5SHY5045L0020
  • ABB 3BSE042237R1 PP836 Panel 800 Control System
  • ABB AC 800M Controller Hardware PM866
  • ABB 3BSC950192R1 TK850V007 CEX-Bus Extension Cable
  • ABB 3BHE023784R2330 PP D113 B01-23-111000: AC 800PEC
  • AO801 ABB Ability™ System 800xA® hardware selector
  • ABB EXC3BSE018106R1 CI855K01 MB 300 Dual Ethernet Port Kit
  • 57160001-AZ DSTD 150 Connection Unit ABB
  • RET670 - Transmission transformer protection 丨ABB
  • ABB EL3000 series EasyLine Continuous Gas Analyzers Model EL3020 EL3040
  • Analog signal converters Overview ABB 1SVR011718R2500
  • ABB Procontic CS 31 series ICST08A9
  • ABB ControlIT AC 800PEC Control System PPD512A10-150000
  • ABB REU615E_D VOLTAGE PROTECTION AND CONTROL RELAY
  • UFC911B108 3BHE037864R0108 ABB Main control board
  • ABB REM610C55HCNN02 Motor protection relay REM610
  • ABB 3BSE013231R1 TU811 TU811V1 Compact Module Termination Unit 1x8 signal terminals.
  • ABB GOP2 G2010A 10.4ST Interface Panel B416302
  • ABB IMRIO02R IMRIO02,Remote I/O Module
  • ABB Relion 610 Series