KONG -Y
NameDescriptionContent
Location:
product
DS200RTBAG2A Relay Terminal Board (RTBA)
❤ Add to collection

DS200RTBAG2A Relay Terminal Board (RTBA)

DS200RTBAG2A
U.S.$115989.00
U.S.$47830.00
U.S.$45438.50
U.S.$44481.90
Weight:1.280KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
DS200RTBAG2A

Part Number DS200RTBAG2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200RTBAG2A is a relay terminal board developed by GE under Mark V series. The Relay Terminal Board (RTBA) for the DS200 is an optional board that is also known as a relay card. The RTBA offers ten relays, three of which have four form C contacts rated at 5 A, and seven of which have two form C contacts rated at 10 A. These relays can be operated remotely by the user or directly from the LTB board's relays. Depending on the group number of the board, there are three coil voltages for the RTBA relays. The coil voltages that are accessible include 115 V ac, 50/60 Hz, 24 V do, and 110 v de (RTBAG1, RTBAG2) (RTBAG3). The RTBA board has jumpers of the Berg type. DS200RTBAG2A Relays An external voltage source placed on the terminal board between KnA (6) and KCM or an internal control voltage source supplied by plug RPL from LTB may be used to activate each RTBA relay. (Take note that JP8 and JP9 provide extra alternatives for K20-K22.) Seven relays on the RTBA board each have two form C connections. The contact connection is indicated by the nomenclature for the terminal board points. The terminal board point K2O NO, for instance, stands for normally open (NO), as opposed to normally closed (NC) or common. K stands for the relay, 20 for which of the seven relays (2026), 7 for which of the two forms C contacts, and NO for ordinarily open (K) (CM). Board Connections The board is connected to the LTBA board using a 16-pin connector (RPL) and a 2-pin connector (OPTPL). Usage of specific RPL connector signals is selectable from jumper. Two stab connectors, CPH (control power hot, positive) and CPN (control power negative), are provided to supply control power to certain pluggable circuits. A jumper controls the use of these stab connectors. The RTBA board includes pluggable circuits as well as relays K27 and K29 access via connectors C1PL C5PL and Y9PL Y37PL. A jumper can be used to select the control power source for these pluggable circuits. Through the RTBA board terminals 1 52, I/O can be connected between the RTBA board relays K20 K26 and external signals. A jumper is used to select the power source for these relays. Application Data - Configurable Hardware A JP nomenclature identifies Berg-type (manually movable) hardware jumpers on the RTBA board, and they must be set appropriately for the application. Most jumper options have already been pre-programmed. On the data sheets that are included with each controller (in the drive/exciter door pocket), these factory preset positions are listed. DS200RTBAG2A Features This card can be used with a wide range of GE exciters and drivers in their cabinets. When utilizing this RTBA board, you can control both remote and LAN I/O terminals. The ten relays on the board are divided into two categories: DPDT and 4PDT. On the board, there are seven DPDT type relays, each with two Form C contacts. A 10A charge is registered on each relay contact. Each relay also contains a 110 VDC coil. Each DPDT relay is located between K20 and K26 on the circuit board. The final three slots on the board are reserved for 4PDT relay types. Within each relay, there are four contacts of this type. These types of contacts have a 1A charge. A 110 VDC coil is also included in each relay. A 130 VAC metal oxide varistor protects all onboard relays (MOV). Relays can be simply removed and replaced as needed. DS200RTBAG2A Board Replacement Turn off the drive and wait several minutes for all of the capacitors to discharge. Before touching any electrical circuits, make sure the power is turned off. To access the board, open the cabinet door on the drive (The RTBA board is usually found beneath the drive's board rack.) Remove all cables from the RTBA board with care. Remove the four screws with washers that secure the RTBA board to the four standoffs. Place all configurable items on the replacement (new) board in the same position as those on the replaced board (old board). Place the new board on the four standoffs using the four screws and washers that were removed in step 4. Reconnect all cables that were disconnected in step 3, making sure that each connector is properly seated at both ends. Reconnect all individual wires that were disconnected in step 3, making sure that each wire is securely fastened in the terminal.RELAY CARD

  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software
  • Bently 2300/20 and 2300/25 2300 Vibration Monitors
  • ABB NGC8206 Natural Gas Chromatograph Dual Unit
  • MOTOROLA MVME2400 TM VME Processor Modules
  • 5320 Series Foxboro DCS Control Network Ethernet Equipment
  • ExtremeSwitching™ 5420 Series
  • WOODWARD EGCP-3 Engine Generator Control Package LS (Load Sharing)
  • 5520 Series Universal Edge/Aggregation-Switch Platform
  • X440-G2 Series
  • EMERSON FloBoss™ S600 Flow Manager Specification Sheet
  • KONGSBERG RAIV400 Remote Analogue Input, Voltage
  • RMP420-Remote Multipurpose Input/Output Kongsberg
  • 610 serie ABB Feeder Protection REF610 Product Guide
  • Triconex 3351S2 Controller Features
  • HBRF Megamax – Emax2 Air Circuit Breaker ABB
  • ABB MEASUREMENT & ANALYTICS | DATA SHEET LS4000 Diode laser analyzer
  • Pressductor Pillowblock Load Cells Vertical Measuring PFCL 201 User manual
  • PARKER BFR5K Series
  • AC 900F controller ABB
  • Uniop ePAD05 and ePAD06 Technical description
  • Hitachi ABB Communication Unit 560CMR02
  • MOTOROLA MVME5500 Series VME Single-Board Computer
  • ABB Symphony Plus SD Series HPC800 controller
  • ABB AC800M Controller Hardware System
  • ABB AC800M PROFIBUS DP Installation System
  • ABB Freelance 800F AC800F Control systems
  • ABB Compact control system replaces PLC AC700F
  • abb Triguard SC300E 3BNP004720R101 TMR Safety Products
  • ABB Distributed busbar protection REB500
  • ABB Advant Controller 400 series
  • ABB MEASUREMENT & ANALYTICS | PRODUCT GUIDE
  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-