KONG -Y
NameDescriptionContent
Location:
product
DS200RTBAG2A Relay Terminal Board (RTBA)
❤ Add to collection

DS200RTBAG2A Relay Terminal Board (RTBA)

DS200RTBAG2A
U.S.$115989.00
U.S.$47830.00
U.S.$45438.50
U.S.$44481.90
Weight:1.280KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
DS200RTBAG2A

Part Number DS200RTBAG2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200RTBAG2A is a relay terminal board developed by GE under Mark V series. The Relay Terminal Board (RTBA) for the DS200 is an optional board that is also known as a relay card. The RTBA offers ten relays, three of which have four form C contacts rated at 5 A, and seven of which have two form C contacts rated at 10 A. These relays can be operated remotely by the user or directly from the LTB board's relays. Depending on the group number of the board, there are three coil voltages for the RTBA relays. The coil voltages that are accessible include 115 V ac, 50/60 Hz, 24 V do, and 110 v de (RTBAG1, RTBAG2) (RTBAG3). The RTBA board has jumpers of the Berg type. DS200RTBAG2A Relays An external voltage source placed on the terminal board between KnA (6) and KCM or an internal control voltage source supplied by plug RPL from LTB may be used to activate each RTBA relay. (Take note that JP8 and JP9 provide extra alternatives for K20-K22.) Seven relays on the RTBA board each have two form C connections. The contact connection is indicated by the nomenclature for the terminal board points. The terminal board point K2O NO, for instance, stands for normally open (NO), as opposed to normally closed (NC) or common. K stands for the relay, 20 for which of the seven relays (2026), 7 for which of the two forms C contacts, and NO for ordinarily open (K) (CM). Board Connections The board is connected to the LTBA board using a 16-pin connector (RPL) and a 2-pin connector (OPTPL). Usage of specific RPL connector signals is selectable from jumper. Two stab connectors, CPH (control power hot, positive) and CPN (control power negative), are provided to supply control power to certain pluggable circuits. A jumper controls the use of these stab connectors. The RTBA board includes pluggable circuits as well as relays K27 and K29 access via connectors C1PL C5PL and Y9PL Y37PL. A jumper can be used to select the control power source for these pluggable circuits. Through the RTBA board terminals 1 52, I/O can be connected between the RTBA board relays K20 K26 and external signals. A jumper is used to select the power source for these relays. Application Data - Configurable Hardware A JP nomenclature identifies Berg-type (manually movable) hardware jumpers on the RTBA board, and they must be set appropriately for the application. Most jumper options have already been pre-programmed. On the data sheets that are included with each controller (in the drive/exciter door pocket), these factory preset positions are listed. DS200RTBAG2A Features This card can be used with a wide range of GE exciters and drivers in their cabinets. When utilizing this RTBA board, you can control both remote and LAN I/O terminals. The ten relays on the board are divided into two categories: DPDT and 4PDT. On the board, there are seven DPDT type relays, each with two Form C contacts. A 10A charge is registered on each relay contact. Each relay also contains a 110 VDC coil. Each DPDT relay is located between K20 and K26 on the circuit board. The final three slots on the board are reserved for 4PDT relay types. Within each relay, there are four contacts of this type. These types of contacts have a 1A charge. A 110 VDC coil is also included in each relay. A 130 VAC metal oxide varistor protects all onboard relays (MOV). Relays can be simply removed and replaced as needed. DS200RTBAG2A Board Replacement Turn off the drive and wait several minutes for all of the capacitors to discharge. Before touching any electrical circuits, make sure the power is turned off. To access the board, open the cabinet door on the drive (The RTBA board is usually found beneath the drive's board rack.) Remove all cables from the RTBA board with care. Remove the four screws with washers that secure the RTBA board to the four standoffs. Place all configurable items on the replacement (new) board in the same position as those on the replaced board (old board). Place the new board on the four standoffs using the four screws and washers that were removed in step 4. Reconnect all cables that were disconnected in step 3, making sure that each connector is properly seated at both ends. Reconnect all individual wires that were disconnected in step 3, making sure that each wire is securely fastened in the terminal.RELAY CARD

  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O