KONG -Y
NameDescriptionContent
Location:
product
DS200TCCAG1A Common Analog I/O Board
❤ Add to collection

DS200TCCAG1A Common Analog I/O Board

DS200TCCAG1A
U.S.$7988.00
U.S.$3445.00
U.S.$3272.75
U.S.$3203.85
Weight:3.550KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
DS200TCCAG1A

Part Number DS200TCCAG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TCCAG1A is a Common Analog I/O Board manufactured by General Electric as part of the Mark V Series used in gas turbine control systems. The CTBA, TBQA, and TBCA terminal boards installed in the "R5" core send analog signals to the Common Analog I/O Board (TCCA), which is housed there. 420 mA inputs and outputs, RTD inputs, thermocouple inputs, shaft voltage inputs, and shaft current inputs are some of the signals that make up this group. Through the 3PL connector, the signals are written to the STCA board. TCCA CONNECTORS: 2PL - Power distribution from the TCPS board in the R5 core. 3PL - The Data Bus between the TCCA, STCA, and core 5 TCCB boards. Conditioned signals are carried on 3PL for transferring to the COREBUS. JAA - Possesses the 4-20 mA output signals to the CTBA terminal board. JBB - Possesses the shaft voltage and current signals and 4-20 mA input signals from the CTBA terminal board. JCC - Possesses RTD input signals from the TBCA terminal board. JDD - Possesses RTD input signals from the TBCA terminal board. JAR/S/T - Possesses Thermocouple input signals and cold junction inputs from the TBQA terminal board. JC - Possesses Power supply diagnostic signals from TCPS. JEE - It is not used CONFIGURATION: Hardware: On the TCCA board, there are three hardware jumpers labeled J1, JP2, and JP3. The serial RS232 port can be enabled or disabled using J1. For card testing, the oscillator is turned off using JP2. For factory testing, JP3 is utilized. Information on the hardware jumper settings for this board may be found in Appendix A. Software: The I/O Configuration Editor, which is located on the HMI, is where the I/O configuration constants for the thermocouples, RTDs, mA inputs and outputs, and the shaft voltage and current settings are entered. TCCA 4 - 20 mA Input Circuit: The circuitry for the 420 mA input signals is provided by the TCCA board. The JBB connector is used to read the signals from the CTBA terminal board. The voltage drop across the burden resistor caused by the transducer current is measured by the TCCA board and written to the I/O Engine via the 3PL connector. TCCA 4-20 mA Output Circuit: Using the JAA connector, the TCCA board's circuitry drives 420 mA outputs to the CTBA terminal board. Typically, these signals are utilized to power remote instruments for monitoring. TCCA RTD CIRCUIT: On the TCCA board is the circuitry for the TBCA terminal board, which provides stimulation to the RTDs. The RTD is supplied with a constant current, and as the temperature varies, the resistance changes, causing the voltage on the RTD to change. The voltage signal is calibrated, measured, and scaled by the TCCA board. By way of the JCC and JDD connectors, the TCCA board reads the RTD signals from the TBCA terminal board. The 3PL connector is used to transmit the signals from the TCCA board to the I/O Engine. I/O configuration constants are used to select the RTD type. THERMOCOUPLE CIRCUIT: The TBQA terminal board reads the thermocouple inputs. The cold junction circuitry on the TBQA terminal board produces the cold junction signals. The TCCA board computes the cold junction compensation using these variables. The actual temperature read by the thermocouple is determined by the TCCA board using the thermocouple input and compensation value. Via the 3PL connector, the I/O Engine reads the value. I/O configuration constants are used to select the types and curves of thermocouples. SHAFT MONITORING: The TCCA board manages the voltage and current monitoring for the turbine shaft. Through the JBB connector, these signals are read from the CTBA terminal board. The 3PL connector is used to write the signals to the I/O Engine. The R5 core location 2 houses the TCCA board. The Turbine Control R5> Micro Application Board A is what it is called. The following operations are defined by the TCCA configuration: RTD inputs and thermocouple inputs Inputs in milliamps Monitoring shaft voltage and current DS200TCCAG1A INSTALLATION: When the drive is fitted, the environment for proper cooling is created. The drive must be mounted in a clean, cool environment that is free of dust and grime. If the drive is mounted on a wall, heat-generating equipment cannot be installed on the other side of the wall. Fans may be required in some areas to provide proper airflow. If that's the case, double-check that the fans are in functioning order. Make sure the drive is put in a location where there is enough space on all sides for air to circulate freely. The drive is set up so that air enters at the bottom and exits at the top as warm air. As it passes over the hot components, it heats up. Air travels over the components because of the cable routing. Ensures that cable bundles do not obstruct air movement or block air vents.ANALOG I/O BOARD

控匠:分布式控制系统DCS:

IC697MDL740

IC670PBI001

IC698CHS117C

DS200TCQAG1BHF

IS200AEPCH1ABC

IC697MDL250

IC697MDL250

760-P1-G1-S1-LO-A20-R

SR489-P5-LO-A20-E

IC670CHS001E

IC697MDL653

IS200VTCCH1CBB

VMIVME-4150


  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software
  • Bently 2300/20 and 2300/25 2300 Vibration Monitors
  • ABB NGC8206 Natural Gas Chromatograph Dual Unit
  • MOTOROLA MVME2400 TM VME Processor Modules
  • 5320 Series Foxboro DCS Control Network Ethernet Equipment
  • ExtremeSwitching™ 5420 Series
  • WOODWARD EGCP-3 Engine Generator Control Package LS (Load Sharing)
  • 5520 Series Universal Edge/Aggregation-Switch Platform
  • X440-G2 Series
  • EMERSON FloBoss™ S600 Flow Manager Specification Sheet
  • KONGSBERG RAIV400 Remote Analogue Input, Voltage
  • RMP420-Remote Multipurpose Input/Output Kongsberg
  • 610 serie ABB Feeder Protection REF610 Product Guide
  • Triconex 3351S2 Controller Features
  • HBRF Megamax – Emax2 Air Circuit Breaker ABB
  • ABB MEASUREMENT & ANALYTICS | DATA SHEET LS4000 Diode laser analyzer
  • Pressductor Pillowblock Load Cells Vertical Measuring PFCL 201 User manual
  • PARKER BFR5K Series
  • AC 900F controller ABB
  • Uniop ePAD05 and ePAD06 Technical description
  • Hitachi ABB Communication Unit 560CMR02
  • MOTOROLA MVME5500 Series VME Single-Board Computer
  • ABB Symphony Plus SD Series HPC800 controller
  • ABB AC800M Controller Hardware System
  • ABB AC800M PROFIBUS DP Installation System
  • ABB Freelance 800F AC800F Control systems
  • ABB Compact control system replaces PLC AC700F
  • abb Triguard SC300E 3BNP004720R101 TMR Safety Products
  • ABB Distributed busbar protection REB500
  • ABB Advant Controller 400 series