KONG -Y
NameDescriptionContent
Location:
product
DS200TCQCG1A Analog IO expansion board
❤ Add to collection

DS200TCQCG1A Analog IO expansion board

DS200TCQCG1A
U.S.$18113.00
U.S.$12008.00
U.S.$11407.60
U.S.$11167.44
Weight:3.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
DS200TCQCG1A

Part Number DS200TCQCG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TCQCG1A is an Analog IO Expander Board manufactured and designed by General Electric as part of the Mark V LM Series used in gas turbine control systems. For additional analog signals read from the I/O cores' terminal boards, the Analog IO Expander board (TCQC) offers scaling and conditioning. LVDT and LVDR excitation is provided by the TCQC board. The core's TCQC board contains the IONET termination for and. The TCQC has that IONET termination if the optional 21> is installed. The TCQC board scales and conditions the mA input for the megawatt transducer signal before writing it to the STCA board using the 19PL connector. The TCQC board scales and conditions the pulse rate inputs. The liquid fuel flow signals and high-pressure shaft speed signals are typically scaled on the TCQC board and written to the TCQA board via the JE connector in the "R1" core. Through the JE connector, the STCA board and TCQC board exchange generator and line signals. TCQC CONFIGURATION: HARDWARE: The output current range for the servo outputs is set using the TCQC board's first 16 hardware jumpers. The source output resistance is chosen by the odd-numbered jumpers, whereas the even-numbered jumpers choose the feedback scaling. For servos 1 through 4, additional feedback scaling possibilities are provided by hardware jumpers 25 through 36, giving them a maximum current range of +/- 240 mA. The RS232 port is designated for card tests by BJ17. The stall timer is enabled by BJ21. The oscillator for factory testing is enabled by BJ22. Not utilized are BJ23 and BJ24. The P15 and N15 supply to the proximity transducers is constrained by BJ18 and BJ20. In some systems, the hardware jumpers JP38 and JP39 control the magnetic pick-up gain for liquid fuel flow signals. TCQC SERVO VALVE REGULATOR OUTPUT CIRCUITS: The TCQC board jumpers scale the current from the TCQA board before sending it to the servo valves for positioning. On the TCQC board, hardware jumpers are utilized to set the reference feedback and output current range. The servo clamp relay and the suicide relays are located on the TCQC board. Bypassing the servo valves, the signal is driven to the ground by energizing the suicide relays. The servo valve can then drift to the bias position as a result. The servo valve receives a positive current when the servo clamp relays are activated. The suicide relays are activated by a signal from the CSP that is written to the TCQA board and then transmitted to the TCQC board. The servo clamp relays are activated by an emergency signal that is written directly to the TCQC board from the TCEA board. TCQC PULSE RATE INPUT CIRCUIT: The JJ connector is used to read the high-pressure shaft pulse rate signals from the TCQE board. On the PTBA board in the "P1" core, the TCQE board signals are generated. The TCQA board receives the high-pressure shaft signals via the JE connector, scales, and conditions them, and then transfers them via 3PL to the STCA board. The JH connector allows the pulse rate inputs from the TTL-type sensors and magnetic speed sensors that are landing on the TBQB terminal board to travel through the TCQC board. The JGG connector can read additional magnetic pickup pulse rate signals that are accessible on the QTBA board. It is not advisable to use some of the signals that land on the PTBA terminal board on both the QTBA terminal board and the PTBA terminal board. If the signals are also landed on the PTBA terminal board, the corresponding screws on the QTBA terminal board are not accessible. TCQC GENERATOR AND LINE FEEDBACK: The TCQC board scales and conditions the signals for generator and line feedback before they are written to the STCA board through the 19PL connector. These signals come from the P1 core's TCTG board, travel through the TCQA board, and then are written to the TCQC board using the JE connector. These signals are used by the STCA board's synch check function. TCQC IONET CIRCUIT: The TCQC board in the "R1" core contains the IONET termination. The X, Y, and Z boards in the P1 core and the TCDA board in the Q11 core are daisy-chained onto the IONET via the JX connector. The 8PL connector is used to write these signals directly to the STCA board. TCQC 4 - 20 mA INPUT CIRCUITS: The circuitry for the two mA input signals is provided by the TCQC board. The JH connector is used to read the first mA input signal from the TBQB terminal board. The compressor stall detection signal is commonly represented by this signal. Through the JGG connector, the second mA input signal is read from the QTBA terminal board. The megawatt transducer signal is normally this signal. Over the 19PL connector, these signals are written to the STCA board.(RST) OVERFLOW BOARD TCQC

IC697MDL740

IC670PBI001

IC698CHS117C

DS200TCQAG1BHF

IS200AEPCH1ABC

IC697MDL250

IC697MDL250

760-P1-G1-S1-LO-A20-R

SR489-P5-LO-A20-E

IC670CHS001E

IC697MDL653

IS200VTCCH1CBB

VMIVME-4150


  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives