KONG -Y
NameDescriptionContent
Location:
product
DS2020FECNRX010A Field power amplifier board
❤ Add to collection

DS2020FECNRX010A Field power amplifier board

DS2020FECNRX010A
U.S.$84921.00
U.S.$7289.00
U.S.$6924.55
U.S.$6778.77
Weight:7.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
DS2020FECNRX010A

Part Number DS2020FECNRX010A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS2020FECNRX010A is a Field Supply Amplifier Board developed by GE under drive control system. A Field Supply Amplifier Board is a component commonly found in turbine control systems. Its main function is to amplify the low-voltage signal received from the field supply and provide a high-voltage output to the turbine control system. It is typically located near the turbine control system's voltage regulator, where it receives the low-voltage signal. It amplifies the signal to the appropriate level needed by the control system and provides a stable and reliable source of power to the system. It is a type of field exciter that is designed for use in industrial power generation and distribution applications. It has a 24 A NRX capability and makes it an ideal choice for use in demanding industrial environments where high current loads are common. It also features a 10 A shunt, which provides additional protection against electrical overload and other types of damage. This helps to ensure that the device remains reliable and long-lasting, even when used under challenging operating conditions. Features Multiple prong-type connectors are also included on this GE Line Protection Board. The board is mounted on standoffs on another drive component. The signal wires that connect the board to the component to which it is connected begin on the component to which it is attached. The board and the component to which it is connected produce heat and are intended to be connected to a high-voltage current. As a result, the drive must be placed in an atmosphere with enough free-flowing air to keep the drive and its components cool. Once the drive is mounted, you'll observe if it stays cool or if the temperature rises to the point where it reaches the high-temperature threshold and shuts down. First, assess if the drive will be surrounded by other heat-generating equipment and if the components will be too close together. Even if the gadgets generate heat, there is room for the hot air to escape. Fans may be required between the drives and other devices. Hoods are sometimes used to gather warm air and vent it out into the surroundings. Make sure the hoods are clean and large enough to do their job. Make sure there is no equipment in surrounding rooms that heat the walls and contributes to the heat around the drive. Jumpers and Terminal Blocks: Features 7 jumpers and 2 terminal blocks with 3 terminals each. The jumpers are labeled JP1 through JP7, and they serve as connectors or switches to configure specific settings or connections on the board. The terminal blocks provide a convenient way to connect wires or cables to the board, typically for power or signal purposes. Prong-Type Connectors: Incorporates a number of prong-type connectors. These connectors are designed to establish electrical connections with external devices or components. They usually consist of male and female connectors that fit together securely, ensuring reliable signal or power transmission. Mounting and Standoffs: Mounted on standoffs, which are raised supports that provide spacing between the board and another drive component. This arrangement allows for proper airflow around the board, promoting cooling and preventing heat buildup. The standoffs ensure a secure and stable attachment of the board to the drive component. Signal Lines and Source: The signal lines, which carry data or information, connect to the board and originate from the attached component. These lines establish the communication pathway between the board and the external devices or systems it interacts with. The attached component serves as the source of these signals, providing input or output data to or from the board. Heat Generation and Cooling: Both the board and the attached component produce heat as they operate. To maintain optimal performance and prevent damage, the drive must be placed in an area with adequate airflow. Freely moving air helps cool the drive and its internal components. Proper cooling is essential to avoid overheating, which could lead to system malfunctions or automatic shutdowns. Characteristics Jumpers and Terminal Blocks: The board features 7 jumpers and 2 terminal blocks with 3 terminals each. The jumpers are labeled JP1 through JP7, and they serve as connectors or switches to configure specific settings or connections on the board. The terminal blocks provide a convenient way to connect wires or cables to the board, typically for power or signal purposes. Prong-Type Connectors: The board incorporates a number of prong-type connectors. These connectors are designed to establish electrical connections with external devices or components. They usually consist of male and female connectors that fit together securely, ensuring reliable signal or power transmission. Mounting and Standoffs: The board is mounted on standoffs, which are raised supports that provide spacing between the board and another drive component. This arrangement allows for proper airflow around the board, promoting cooling and preventing heat buildup. The standoffs ensure a secure and stable attachment of the board to the drive component. Signal Lines and Source: The signal lines, which carry data or information, connect to the board and originate from the attached component. These lines establish the communication pathway between the board and the external devices or systems it interacts with. The attached component serves as the source of these signals, providing input or output data to or from the board. Heat Generation and Cooling: Both the board and the attached component produce heat as they operate. To maintain optimal performance and prevent damage, the drive must be placed in an area with adequate airflow. Freely moving air helps cool the drive and its internal components. Proper cooling is essential to avoid overheating, which could lead to system malfunctions or automatic shutdowns. Temperature Monitoring: Once the drive is in operation, it is crucial to monitor its temperature. If the temperature exceeds a specific threshold, the system may be designed to automatically shut off to prevent damage. This feature ensures that the drive remains within safe operating limits and avoids potential hazards caused by excessive heat buildup. Proximity to Other Heat-Producing Equipment: It is important to consider the proximity of other heat-producing equipment to the drive. If the drive is surrounded by such devices, it may experience higher ambient temperatures, leading to increased heat accumulation. To mitigate this issue, sufficient space should be provided to allow warm air to escape and prevent heat buildup. Additionally, the presence of other electronics near the drives may necessitate the use of fans or additional cooling mechanisms to maintain proper operating temperatures for all components involved. Contact and Solenoid Outputs For contact outputs, the Mark V only employs magnetic relays of the plug-in variety (no solid state outputs). Each contact is a three-wire form C with a common center conductor, one generally open and one normally closed contact. In a TMR system, the three controllers R, S, and T each independently decide the contact output state, and the relay driver casts two of the three votes. A diagnostic alarm is announced if there is a disagreement among the three controllers. Depending on the jumper settings made on the terminal boards, some outputs can be internally powered by either 115 V or 125 V ac. Transformer-mechanical relay contacts are rated out of the box. Servo-Valve Automatic Calibration The process of Servo-Valve Automatic Calibration, also known as AUTOCAL, is a function that establishes a precise relationship between the position of a servo-valve and the corresponding feedback voltage it generates. This calibration process plays a crucial role in achieving accurate and reliable position control of the servo-valve outputs (SVOs) within a system. AUTOCAL focuses specifically on calibrating the feedback signals in the position control sections of the different SVOs. These signals provide crucial information about the actual position of the servo-valve and are used to ensure precise control and movement of the actuator or device it is associated with. The calibration process involves calculating the values of I/O Configuration Constants. These constants are used to scale the input voltage signals received from the device's position, and they determine the proportional voltage output from the feedback devices, typically Linear Variable Differential Transfer/Reactor (LVDT/R). Before initiating the automatic calibration process, several prerequisites must be met. Firstly, the actuator or device connected to the servo-valve must be mechanically adjusted to ensure that it operates within the desired range of motion. This includes setting the mechanical end stops correctly, which define the limits of the actuator's movement. Additionally, the LVDT/R, which is responsible for providing feedback on the position of the servo-valve, needs to be adjusted accurately to the correct minimum voltage position. This ensures that the LVDT/R provides consistent and reliable feedback throughout its operating range. Once these mechanical adjustments and LVDT/R positioning are correctly set, the AUTOCAL function can be executed. During the calibration process, the system calculates and determines the appropriate I/O Configuration Constants for each SVO's position control section. These constants serve as scaling factors, converting the input voltage signals into proportional feedback voltages that accurately represent the position of the servo-valve. By calibrating the feedback signals through AUTOCAL, the system achieves enhanced precision and accuracy in controlling the servo-valve and, consequently, the associated actuator or device. This calibration process ensures that the servo-valve operates within the desired range, accurately responds to control inputs, and provides reliable position feedback for optimal system performance. Product Attributes The primary purpose is to amplify and regulate the field supply, ensuring stable and uninterrupted operation. This product boasts several key attributes and installation considerations that are essential for optimal functionality. Power Supply Requirements To power the board, a +5 V dc power supply with a current rating of 6 A is required. This supply voltage is crucial for enabling the board to effectively manage the field supply within the drive system. Relay Channels for Versatile Control Features 12 relay channels, providing a high degree of flexibility and versatility in controlling and switching various electrical signals and components within the drive system. This capability empowers your system to adapt to different operational requirements. Primary Power Input The specified power supply voltage for the FECNRX010A is 28 V dc, serving as the primary power input for the board. This voltage is essential for sustaining the board's operations and ensuring its reliability. Board Configuration The board incorporates 7 jumpers, identified as JP1 through JP7, allowing for customizable configurations to suit specific operational needs. Additionally, it features 2 terminal blocks, each equipped with 3 terminals, enhancing connectivity options. Installation and Environmental Considerations Mounting: Install the board on standoffs, securely affixed to another component within the drive system. Signal Wires: Ensure that signal wires connecting to the board originate from the attached component, maintaining a secure and reliable connection. Heat Generation: Both the board and the attached component generate heat due to high-voltage current connections. Cooling Requirement: To prevent overheating, the drive and its components must be placed in an environment with free-flowing air for adequate cooling. Temperature Monitoring: After installation, diligently monitor the drive's temperature. If it approaches a high-temperature threshold, it may automatically shut off to prevent damage. Nearby Devices: Check if surrounding heat-generating devices might affect the drive's temperature. Ensure adequate spacing between components. Ventilation: Create space for heated air to escape. Consider installing fans between drives and other devices to ensure proper ventilation. Fan Functionality: Confirm that any installed fans are capable of moving enough air and are in good working condition to assist in cooling. Hood Usage: Hoods can be employed to collect and exhaust heated air from the environment if necessary to regulate temperature. Hood Maintenance: Regularly clean and maintain hoods to ensure they are appropriately sized and functioning effectively to dissipate heat. Application Software Application software is developed using in-house software automation tools that select and integrate proven GE control and protection algorithms with the I/O, sequencing, and displays for each application. Fixed-point data can be processed at a frame rate of 62.5 ms (16 Hz). The frame rate is the amount of time it takes to read control inputs, condition them, run application software, and send output commands to the control valves. While the turbine is running, changes to the application software can be made with password protection and downloaded to the control module. All application software is stored in nonvolatile EEPROM memory in the control module. The application software is executed sequentially and is represented in the form of a ladder diagram. Maintenance personnel can add or change analog loops and sequencing logic using a library of software building blocks. There are also math blocks available. The application software documentation, which includes the primary elementary diagram, I/O assignments, and tuning constant settings, is generated directly from the source code and can be printed on-site. System Control Panel To monitor, control, and protect the unit, the TMR control panel employs three identical control processors, R, S, and T (collectively referred to as Q). Each of the three control processors performs the same operations. The majority of the inputs to the three control processors, as well as the majority of the outputs, are voted on. The Simplex control panel is made up of one control processor, R. As a result, it does not use SIFT technology and is incapable of controlling or protecting a turbine while its single control processor is being repaired. A communicator processor, C; a protective core, P; a power distribution core, PD; a communicator processor digital I/O core, CD; and a control processor digital I/O core, QD1 round out a typical Mark V control panel. A backup communicator processor, D, and additional digital I/O core(s), QD2, are available as optional cores.FLD EXC. 10A (NR-NP)

DS200DCFBG1BLC

MS90376-12Y

VMIVME-7807RC

SERVOSTAR 310

IS200ERIOH1AAA

IS220PSCAH1A 336A4940CSP9

D20-PS LFDSC143-4000

IS200TDBTH6ABC

DS200SHVMG1AGE

IS2020RKPSG3A

DS200SHVMG1AFE

IC660ELB912

IS220PPRFH1A

IC698PSA350

HYDRAN M2

IC693PWR321

IS215VCMIH2BB IS200VCMIH2BCC


  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-
  • 3BHB007441P0001 LDSTA-01 ABB inverter control CPU driver board
  • ABB LD series LDMTR-01 63940135F I/O module
  • ABB 7525A38G01 SCV-MR 600:5 7525A38
  • ABB C86-94639 Sensor Module Assembly,PCBA,TUV
  • Melcher W Series 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters Convert Select LWN2660-6E-G
  • ABB NDBU-95C; Star connection branching unit (9 outputs= 9 pcs 10 Mb)
  • ABB A2C 250 TMF 250-2500 4p F F 1SDA066792R1
  • ABB YC E1.2..E6.2-XT7M 220-240 VAC/DC 1SDA073687R1
  • ABB Electromagnetic flowmeter WaterMaster
  • ABB Model: S-PKZ2, ZM-25 -8- PKZ2,ZM-16-PKZ2,PS201PRE ,PKZMO-10-T
  • ABB 3BHE004385R0001 UNS 0884a, V1:Current Sensor 2000A
  • ABB 3AXD50000182992 ZCU-14 PACKED SP; CONTROL UNIT
  • ABB INDUSTRIALDRIVES UCU-22, UCU-23 andUCU-24control units
  • ABB LDMU series LDMUI-01 61320946C Overview of interface module
  • ABB HIEE410506P104 UAC389 Processor module
  • ABB BN5930.48 24VDC safety relay
  • ABB 3BHE006373R0101 XVC769 AE101 PC board
  • ABB 58967441 NTAC-02; PULSE ENCODER INTERFACE
  • ABB NEMA full voltage power devices
  • ABB 800xA Device Management and Fieldbus Overview
  • ABB FOUNDATION™ Fieldbus Linking Device LD 810HSE Ex V1.0
  • ABB 3BSE017235R1 PXAH 401 Operator unit
  • ABB Drives series SCYC51213 63911607C DRIVER BOARD
  • SCYC51220 63901075C ABB control panel
  • ABB HL000986P0006 High density digital input/output module
  • 3BHB004791R0101 ABB medium voltage drive ACS2000 series
  • ABB 3BHB009175R0001丨3BHB005922R0001 UNS 0880a-P,V1:CIN PCB completed
  • MTA025 EBG92026 ABB MTA series current transformers
  • ABB AF400-30-11-70 1SFL577001R7011
  • ABB 12556917-738385 RADOX GKW cable
  • ABB THYRISTOR MODUL WE-73-10/CH 64421956
  • ABB 969.105EBG 540KKS166899 automatic system
  • ABB CH-3185 3BHL000986P1006 Abbability 800xa automation system
  • ABB 500CMP04 HE401314/0001 1MRB150051R1 power-supply module
  • ABB 500TTM02 1MB150021R01161HF930712X010 control panel
  • ABB 500MBA01 1MRB150003R0002 1MRB200053/L operation manual
  • ABB 500MBA02 1MRB150003R000/B Safety rules
  • ABB 500MBA02 1MRB150003R0003 1MRB200053/M Full range of power modules
  • ABB AC 800PEC system 3BHE023784R1023 PP D113 B01-10-150000
  • ABB 4LA41100102V1.2 KB2 Display Unit
  • ABB 60 - 65 A perfect fit
  • ABB PPD113 B03-23-100110 3BHE023584R2334 AC800PEC Control Systems
  • ABB 3BHE028122R0001 XFD213A control panel
  • ABB 3BSE030220R1 CI854AK01 PROFIBUS-DP/V1 interface
  • AO845A ABB Ability™ System 800xA® hardware selector
  • ABB 64666606 DSMB-02C control panel
  • ABB 68444161 IGBT FS450R12KE3/AGDR-71C
  • ABB CTB810 HN800/CW800 Communications Terminal Board connects to LEFT side of MB810
  • ABB Ability™ Symphony® Plus SD Series controller HPC800
  • ABB 3BSE018293R1 DSAO-120A Analog Output Board 8 Channels
  • ABB REA101-AAA ARC PROTECTION
  • ABB 3BSC950262R1 TK851V010 Connection Cable, 1m
  • ABB I/O Systems - S800 I/O DI810
  • SOE - Infi 90 Series INSEM01 | ABB - DCS Center
  • ABB 3BSE010535R1 PM645B Processor Module
  • ABB Tension Electronics PFEA 111, 112, 122 and 113 User Manual
  • ABB 3HNA018564-001 DSQC355B/ANALOG IO
  • ABB 3BSE020512R2 AI801-eA S800 I/O Systems
  • ABB HIEE200130R0002 AF C094 AE02 ARCnet control panel
  • AC800M series HIEE300885R1 PPC380AE01 ABB
  • ABB SNAT604IFS REV.B code: 61029052 5761861-2B control panel
  • AC 800M - Controller Hardware - ABB
  • CP430 Installation and Operation Manual ABB,1SBC159103M0202
  • ABB 3BSE000355R1 DSPU 131 MA200 Interface Board
  • ICSI16E1 | ABB Procontic CS 31 Input Module Binary
  • MSR04X1 Wiring Accessories | Service and tools | ABB - ABB Group
  • EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X2-AB-DHRIO
  • Protection Cards for AMS 6500 Classic Systems EMERSON
  • EMERSON AMS Trex™ Device Communicator
  • EMERSON AMS 2140 Machinery Health™ Analyzer
  • EMERSON CSI 2140 Machinery Health Analyzer
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB GJR2391500R1210 81EU01H-E / 81EU01 Input Module universal
  • AC31 mit AC1131 Teil 16: Systemtechnik Serie 40/50
  • ABB IEPAS02 POWER MODULE +5, +/-15, 24
  • ABB 5SHX0660F0001 Asymmetric Thyristor IGCT series
  • ABB HIER464920P0001 CURRENT RELAY,UNS 0017A-P
  • ABB 3AFA408368 IMA MODULE
  • ABB SWISS MADE 5SHY5045L0020
  • ABB 3BSE042237R1 PP836 Panel 800 Control System
  • ABB AC 800M Controller Hardware PM866
  • ABB 3BSC950192R1 TK850V007 CEX-Bus Extension Cable
  • ABB 3BHE023784R2330 PP D113 B01-23-111000: AC 800PEC
  • AO801 ABB Ability™ System 800xA® hardware selector
  • ABB EXC3BSE018106R1 CI855K01 MB 300 Dual Ethernet Port Kit
  • 57160001-AZ DSTD 150 Connection Unit ABB
  • RET670 - Transmission transformer protection 丨ABB
  • ABB EL3000 series EasyLine Continuous Gas Analyzers Model EL3020 EL3040
  • Analog signal converters Overview ABB 1SVR011718R2500
  • ABB Procontic CS 31 series ICST08A9
  • ABB ControlIT AC 800PEC Control System PPD512A10-150000
  • ABB REU615E_D VOLTAGE PROTECTION AND CONTROL RELAY
  • UFC911B108 3BHE037864R0108 ABB Main control board
  • ABB REM610C55HCNN02 Motor protection relay REM610
  • ABB 3BSE013231R1 TU811 TU811V1 Compact Module Termination Unit 1x8 signal terminals.
  • ABB GOP2 G2010A 10.4ST Interface Panel B416302
  • ABB IMRIO02R IMRIO02,Remote I/O Module
  • ABB Relion 610 Series