KONG -Y
NameDescriptionContent
Location:
product
Jaquet  FTFU 3024-E01   377Z-03981   with input card -E01
❤ Add to collection

Jaquet  FTFU 3024-E01   377Z-03981   with input card -E01

Jaquet  FTFU 3024-E01   377Z-03981   with input card -E01

U.S.$10450.00
U.S.$9640.00
U.S.$9158.00
U.S.$8965.20
Weight:1.290KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Description

Jaquet  FTFU 3024-E01   377Z-03981   with input card -E01


Jaquet  FTFU 3024-E01   377Z-03981   with input card -E01

PSU Monitor

Green if 18V < V < 33V

No system fault (Green)

Sensor monitor OK = green

Direction backwards = yellow

Limit 1. 2. 3. 4 passed high /low = green

(dependent on configuration)

For factor setting only

PSU Monitor

Green if 18V < V <33V

Self check system fault = red

Sensor fault = red

Direction forwards = yellow

Limit 1. 2. 3. 4 passed high /low = red

(dependent on configuration)

Sensor frequency = yellow

Sensor current :

10 V corresponds to 30 mA (E01)

Upper sensor monitor current limit

10V corresponds to 30 mA (E01)

Test point ; Refrence signal input

Test point ; scaled trigger level

0V corresponds to 0%, 10V to 100%

(of max 3.5V) (E01)

Lower sensor monitor current limit

10V corresponds to 30 mA (E01)

Test point ; Reference signal input

6.1 Statistics

Mean Time Between Failure for each channel (without voting)

Mean Time Between Failure for each OSP channel (FTFU 3024)

Mean Time Between Failure for each signal monitoring channel (FTBU 3x34)

PFHg  according to IEC 61508-2

DC % according to IEC 61508-2

: 2.69e-8 fits

: 94.23%

: 188683 hours #  21.5 years

: 230700 hours #  26.0 years

: 1036000 hours # 118 years

Life duration for the system is 20 years. During this period the data integrity of the programable devices are garanted, this time

is equivalent to the MTBF of the channel. After this period the overspeed protection system must be replaced.

6.2 Special specifications :

6.2.1 CSA specifications

• Pollution Degree 2 environment

• Installation Category II

• Altitude : sea level

• Humidity : 0%...90% condensation to be avoided

• Electrical supply 24 Vdc, max. 8A, Double or Reinforced insulated from mains

• The Ft3000 rack system must be installed in a indoor environment.

• Operating temp -5...+40ºC

Reference conditions: Operating temperature +20ºC

Supply within defined limits

Smallest measuring range:   0...1.000 Hz

Largest measuring range:   0...35.00 KHz

Once the machine factor M is defined (M = Freq. In Hz/ measured value eg rpm), the input of  measuring range and limit

values is directly in the chosen physical units eg rpm. In place of the machine factor, the number of pulses per rev from the

pole wheel may be entered. Moreover once the nominalspeed is defined (=100%), limits can be given as a percentage of

nominal. The measured range may be continuously exceeded up to 55KHz without affecting functionality or causing any

damage to the unit.

Sensor signal input-

Frequency input 1

Input card -0X for frequency input 1. plugged onto the motherboard FTFU 3024

Input card E-01:

potential free, isolation 500V, 50Hz,1 Min. from electronics and earth ie from front panel

and card frames.

for connection of electromagnetic, ferrostat or HF sensors, proximity switches and sensors

with line amplifiers.

Input impedance:   100kohm

Input voltage:               50mV...80V rms

Bandwith  (-3dB)    : 0.5 Hz /3.3 kHz

Frequency domain for pulsed signals   : 0.02Hz / 30kHz

Input level for sinus signals    : 50 mv rms at min trigger

Input level for pulsed signals    : 10Vpp at 20% trigger  level

Trigger level:               adjustable between 0 and +3.5V via front panel

trimmer T. The voltage at test point T to ground of

fixed hysteresis of 50mV rms = 141mVss

Integral pull up (+12V) and pull down (0V) resistance of  11 kOhm for connecting 2 wire

sensors, jumper selectable.

Sensor monitoring of 2 and 3 wire sensors, jumper selectable -If the supply current is

< I min or > I max a defect is signalled by the green LED ‘MO’ off and the red LED ‘MO’

on.

I min is set via front panel trimmer ‘L’

I max is set via front panel trimmer ‘H’

A voltage at test points ‘L’ and ‘H’ to ground from 0...10V corresponds to supply current of

0...30mA.

A voltage from 0...10V at test point ‘M’ corresponds to the actual supply current of  ...30mA.

To adjust the trimmers the module must be plugged onto an extension card to open the seal.

Integral sensor supply of +11.5...12.5V, max 25mA, short circuit proof  (max 40mA).



  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module