The Jaquet FTV 3090 (Part Number: 377Z-03985) is a highly reliable relay card designed as an auxiliary plug-in module for the Jaquet FT 3000 Multi-Channel Overspeed Protection and Monitoring System. Designed specifically for critical rotating machinery like steam and gas turbines, this module plays an essential role in system voting logic (e.g., 2oo3 voting architectures) to prevent catastrophic overspeed events.

1. Product Introduction / Overview

The Jaquet FTV 3090 acts as an expansion relay module that slots directly onto the FT3000 motherboard (such as the FTFU 3024). When integrated into a standard 19-inch subrack system, it adds high-capacity relay capabilities. The FTV 3090 is commonly utilized in heavy industrial environments—such as power generation plants, chemical processing facilities, and marine propulsion—to physically trigger machinery trips or sound critical alarms when safety limits are breached.

2. Technical Parameter List

The core hardware specifications and contact ratings for the FTV 3090 auxiliary card include:

ParameterSpecification
Model TypeFTV 3090
Part Number (P/N)377Z-03985
Relay Count4 independent relays
Contacts per Relay4 potential-free changeover (SPDT) contacts
Relay Operational ModesProgrammable: Non-latching, Mono-stable, or Latching
Max AC Rating (Standard)250 VAC, 2 A, 125 VA
Max DC Rating (Standard)220 VDC, 2 A, 60 W
UL / CSA Safety Ratings

AC: 30 V, 2 A, 60 VA / 125 VAC, 0.6 A

 

DC: 30 V, 2 A, 60 W / 110 VDC, 0.6 A

Configuration InterfaceVia PC (using FT3000 Windows Software via communication card)
Visual IndicatorsFront panel status LEDs
WeightApprox. 0.15 kg (0.33 lbs)

3. Product Features / Core Advantages

Voting Logic Integration: Crucial for setting up 1oo2. 2oo2. or 2oo3 (two-out-of-three) voting loops. This prevents false trips while guaranteeing a shutdown if a genuine fault occurs.

Galvanic Isolation: Features potential-free contacts to isolate critical control logic loops from high-power external circuitry.

Configurable Fail-Safe Modes: Relays can be set to normal (energized) or inverse (de-energized on trip) modes to suit fail-safe system preferences.

High System Availability: Operates within the SIL 3 certified FT3000 ecosystem.

Live Status Diagnostics: Features front-panel LED indicators that allow maintenance engineers to immediately verify which relays are active, saving valuable troubleshooting time.

4. Model Classification

Within the Jaquet FT3000 platform, the FTV 3090 is classified alongside other specialized cards:

FTFU 3024 Series (Motherboards): Core speed measurement and sensor watchdogs (e.g., FTFU 3024-E01. P/N 377Z-03981).

FTV 3090 (Relay Card): Dedicated multi-contact safety tripping and voting.

FTW 3013 (Analog Card): Converts frequency to isolated, scalable current outputs (0/4–20 mA).

FTBU 3034 (Trip Chain Card): Used to route up to six trip commands into a single hardware safety chain.

5. Environmental Tolerance Conditions

Operating Temperature: 0°C to +60°C (designed to handle peak temperatures up to +70°C for a maximum of 2 hours).

Storage Temperature: -25°C to +85°C.

Relative Humidity (rH): Up to 75% average annually; up to 90% maximum non-condensing over any 30-day period.

6. Installation Method

The FTV 3090 card is designed strictly as an internal plug-in module for the FT3000 19" rack assembly:

Power Down: Ensure the entire subrack power supply (such as FTZ 3064 or FTZ 3061) is disconnected before installing or replacing cards.

Alignment: Align the card along the designated motherboard guide rails of the corresponding FTFU 3024 channel.

Insertion: Slide the card firmly back into the chassis until the rear multi-pin DIN connector is fully seated into the backplane.

Securing: Fasten the front panel screws to ensure solid grounding and vibration resistance.

7. Operating Instructions

System Programming: Parameters (such as non-latching, mono-stable, or latching modes) must be configured prior to operation using the Jaquet FT3000 Windows Configuration Software connected via the FTK 3072/3073 communication module.

Resetting Latched Relays: If a relay is programmed to latch upon a limit violation, it will remain tripped even after speed drops below the threshold. A manual reset command must be sent via binary inputs on the motherboard or via the PC software interface.

Periodic Proof-Testing: In high-integrity installations, perform proof-testing at regular intervals. Use a multi-channel frequency generator (e.g., IST-101) to simulate overspeed conditions on the respective channels and verify that all 4 relays on the FTV 3090 trip in accordance with the programmed voting logic


  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module