KONG -Y
NameDescriptionContent
Location:
product
GE-IS200STAIS2A - DINRAIL TRBD ANALOG
❤ Add to collection

GE-IS200STAIS2A - DINRAIL TRBD ANALOG

IS200STAIS2A - DINRAIL TRBD ANALOG
U.S.$7589.00
U.S.$3889.00
U.S.$3694.55
U.S.$3616.77
Weight:8.990KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200STAIS2A - DINRAIL TRBD ANALOG

Part Number IS200STAIS2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS200STAIS2A is a Simplex Analog Input terminal board developed by GE under Mark VIe control system. The Simplex Analog Input (STAI) terminal board is a small analog input terminal board that connects to the pack and accepts 10 analog inputs and two analog outputs. The ten analog inputs support two-wire, three-wire, four-wire, and externally powered transmitters. The two analog outputs are 0-20 mA, but one of them can be jumpered to 0-200 mA current. The board is only available in a simplex configuration. Features High-Density Euro-Block Terminal Blocks: Incorporates high-density Euro-block terminal blocks, which are known for their excellent electrical and mechanical properties. These terminal blocks provide a secure and reliable connection for various input and output signals, facilitating easy and efficient wiring of the system. On-Board ID Chip for System Diagnostics: To enhance system diagnostics and monitoring, the component is equipped with an on-board ID chip. This chip uniquely identifies the board to the system, allowing for easy identification and troubleshooting. It provides essential information about the board's status and configuration, making maintenance and troubleshooting processes more streamlined and effective. Compatibility with PAIC I/O Pack: Fully compatible with the PAIC I/O pack. This compatibility ensures seamless integration between STAI and the PAIC I/O pack, enabling the exchange of data and signals in a smooth and synchronized manner. Ethernet Connectivity: The I/O pack connects to the controller via Ethernet, enabling fast and reliable communication between the I/O pack and the central controller. Ethernet is a widely adopted communication protocol in industrial applications due to its high data transfer rates, low latency, and robustness. D-Type Connector: The pack features a D-type connector for easy and secure connection to the controller. The D-type connector is a standard interface widely used in industrial applications for its reliability and ease of use. Support for Simplex Systems: Specifically designed to support simplex systems. In a simplex configuration, a single controller and I/O pack work together to ensure system operation. This setup simplifies the system architecture and is often used in applications where redundancy is not a critical requirement. Long Cable Length Support: Allows for a maximum two-way cable resistance of 15 ohms and supports cable lengths of up to 300 meters. This feature is beneficial in installations where the I/O pack needs to be located at a significant distance from the controller, without compromising signal integrity and performance. Installation During the installation of the STAI (Signal Transmitter Analog Input), several steps and considerations need to be taken into account. The module, along with a plastic insulator, is mounted on a sheet metal carrier. This carrier provides a stable platform for the module and ensures proper alignment. The carrier can be further mounted on a DIN-rail, which offers a standardized method of installation in industrial environments. Alternatively, the STAI module with the insulator can be mounted directly on a sheet metal assembly, securely bolted to a cabinet or other suitable surface. For wiring, it is recommended to use 18 AWG wires, preferably shielded twisted pair cables. These cables are designed to minimize electromagnetic interference and ensure reliable signal transmission. The use of shielded twisted pair cables helps maintain the integrity of analog signals and reduce the risk of noise or signal degradation. The component includes terminal blocks that facilitate the connection of analog inputs and outputs. These terminal blocks serve as interface points for the various types of analog signals supported by the module. Some of the supported analog input types include two-wire transmitters, three-wire transmitters, four-wire transmitters, externally powered transmitters, and voltage inputs with ranges of 脗卤5 V or 脗卤10 V DC. Similarly, the module supports analog output signals in the form of 0-20 mA and 0-200 mA current ranges. To ensure proper grounding and minimize interference, an I/O cable shield terminal is provided. This terminal allows for the connection of shielded cables, which helps protect the analog signals from external electrical noise and disturbances. By following the appropriate installation procedures and utilizing the correct wiring and connections, the STAI module can be successfully integrated into the system, enabling reliable analog signal transmission and processing. Operation Power Supply: All transmitters connected to the terminal board have access to a 24 V DC power supply. This power supply ensures a consistent and reliable source of power for the transducers or sensors used in the system. Input Selection: By using jumpers, you can select between current and voltage inputs for the STAI module. This flexibility allows compatibility with a wide range of transducers or sensors that provide either current or voltage outputs, depending on the specific requirements of your application. Analog Output Circuits: The STAI module is equipped with two analog output circuits. One circuit operates within the 4-20 mA current range, providing a standardized output signal. The second circuit can be configured, via a jumper, to operate within either the 4-20 mA current range or the broader 0-200 mA range. The selection of the output range depends on the specific application and the compatibility requirements of the receiving devices or systems. Limitations for TMR or TBAI Applications: It's important to note that the terminal board of the STAI module cannot be used for Triple Modular Redundant (TMR) or Terminal Board Analog Input (TBAI) applications. This limitation arises from the presence of only one cable connection on the terminal board, which is insufficient for achieving redundant or expanded input capabilities typically required in TMR or TBAI setups. Configuration It offers configuration options through the use of jumpers. 

These jumpers play a crucial role in customizing the functionality of the board according to specific requirements. By referring to the installation diagram, the location of these jumpers can be identified. Jumpers J1A through J8A provide the ability to choose between current or voltage input for the terminal board. This flexibility allows for compatibility with different types of input signals, catering to a wide range of applications. Jumpers J1B through J8B determine whether the return is connected to the common terminal. The common terminal serves as a reference point or ground for the input signals. By adjusting these jumpers, it is possible to establish whether the return is connected to the common terminal or not for each input. For precise input current selection, jumpers J9A and J10A are available. These jumpers allow you to choose between an input current of 1 mA or 20 mA, depending on the specific requirements of the system. Additionally, jumpers J9B and J10B also impact the connection of the return to the common terminal, providing further control over the circuit configuration. Among the available jumpers, J0 serves a unique purpose. Jumper J0 allows the selection of either 20 mA or 200 mA for output 1, providing the necessary flexibility to adapt the terminal board's output to the desired specifications. Diagnostics The board incorporates diagnostic tests on the terminal board to ensure proper functionality and identify potential issues. These diagnostic tests involve specific mechanisms and devices that enable the board to detect and report faults or hardware incompatibilities. The diagnostic procedures are as follows: Voltage Drop Test: The board utilizes a series resistor to measure the voltage drop across it, providing an indication of the output current. By monitoring the voltage drop, the board's I/O processor can assess the health of the outputs. If any one of the two outputs deviates from the expected values or becomes unhealthy, the I/O processor generates a diagnostic alarm or fault. This fault alert notifies users or system administrators that there is a potential issue with the outputs, enabling them to take appropriate actions to rectify the problem. Cable Connector ID Device: Each cable connector present on the terminal board is equipped with its own ID device. This ID device is an integrated chip that contains essential information, including the terminal board's serial number, board type, revision number, and the location of the connector (JR, JS, JT). The ID device is a read-only chip, meaning it can be interrogated by the board's I/O controller to retrieve the encoded information. During the diagnostic process, the I/O controller reads the information from the ID device of each cable connector. It compares this information with the expected values, which are typically pre-programmed or stored within the system. If a mismatch or inconsistency is detected between the read data and the expected values, it indicates a hardware incompatibility between the terminal board and the connected cables. In such cases, the I/O controller generates a hardware incompatibility fault, indicating that there is a mismatch between the terminal board and the connected cables. The hardware incompatibility fault serves as an alert to users or technicians, informing them that the current terminal board configuration and the connected cables may not be compatible. This enables them to address the issue by ensuring the correct cables are used or making the necessary adjustments to achieve compatibility. By incorporating these diagnostic tests, it provides mechanisms to detect potential faults and hardware incompatibilities. These diagnostic procedures enable the board to monitor and assess the health of its outputs and verify the compatibility of the terminal board with the connected cables. The generated diagnostic alarms and hardware incompatibility faults serve as valuable information for troubleshooting and maintenance, aiding in the prompt identification and resolution of any potential issues encountered during the operation of the board.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

  • 81EU50 83SR50 88TK50 Universal I/O and control modules 丨ABB
  • GJR2390200R1411 83SR04R1411 Control Module Universal
  • ABB INSUMMCU2 MCU2A02V24 INSUM® PROFIBUS Gateway Manual SW 2.1
  • ABB REF542 series 1VCR007346 G0028 Function and configuration
  • ABB 216AB61 HESG324013R101 Control Panel-Specifications
  • ABB 216EA61B HESG448230R1/G
  • 216VC62A HESG324442R112/F 丨ABB
  • 500PSM03A 1MRB150038R1 series丨ABB Power control panel
  • REG216, CompactREC216 Numerical Generator ProtectionNumerical Control Unit
  • ABB Panel 800 series 3BSE092980R1 PP886 Standard Panel 15"
  • 500CIM05 1MRB150077R1/B ABB
  • 500CPU05 1MRB150081R1/E ABB-Module
  • 500SCM01 1MRB200059/C 1MRB15004R0001丨ABB Star coupler module
  • ABB SYNCHROTACT ® 5
  • ABB 3BHB006716R0277 SYN 5302a-Z,V277: Auto dual channel Syn
  • ABB Pressductor-PillowBlock Load cells series PFCL201
  • ABB UNS4684A-P,V.1 HIEE305114R00R0001 control panel
  • Tension Electronics PFEA 111, 112, 122 and 113 丨ABB
  • ABB PFRL101C-1.0KN 3BSE023316R1002 Web Tension Measurement
  • 1VCF750090804 HMI SUE 3000 (110...220 V) ABB
  • 57120001-AT DSAO 110 ABB
  • S100 I/O Modules DSAO 120 57120001-EY 丨ABB
  • Advant Controller 500 series 500BIO01 1MRB150005R0001 1MRB200060/E ABB
  • 3BHE023784R2530 PP D113 B01-25-111000: AC 800PEC Static Excitation Systems›UNITROL 6000 X-power
  • ABB EXC3BSE008105R1 SC560 Exchange
  • HR Series Turbine control systems SD Series remote I/O ABB
  • HR Series (Harmony Rack) I/O RSPASI23
  • ABB SPBRC400 Controller with Expanded Memory
  • E3HAB8101-18 Modules Drive System 丨ABB
  • ABB 3BHL000986P7000 LXN 1604-6, 27V 500W
  • ABB REF615_series_ Feeder protection and control
  • ACS 6000 series Medium voltage AC drives for control of 3–27 MW motors up to 3.3 kV
  • I/O Systems - S800 I/O series-ABB
  • SPAJ 140 C Series ABB
  • INCLUDING PFSK 113 7625013-S 丨ABB
  • AC 800PEC The high-performance control system for model-based design
  • HKQCS PARTS ON LINE 129740-002 ABB
  • UNITROL 6000 X-power 3BH022294R0103 GFD233A103
  • AO810 AO810V2 - ABB Ability™ System 800xA® hardware
  • Elastimold® molded vacuum reclosers – MVR MVR 0.44-10KA
  • AC 800M series PM865 3BSE030193R1 discontinued products
  • 1MRK000838-HA ABB RXIDK 2H series
  • ABB 605 series
  • Feeder protection REJ601 BD446NN1XG
  • ABB SAFT183VMC expansion module board unit specifications
  • 3BHB004661R0101 KU C711 AE; GATE UNIT POWER S GUSP
  • PRC3BSE066490R1 PM856AK01 Processor Unit
  • SM560-S (1SAP280000R0001) AC500 CPU Firmware SM560-S-FD-4
  • 769137 Detector 13CO2 10% (Uras26) ABB control unit
  • AC500 CPU Firmware
  • 0002-07-2-00001-01 BMXS Science Module (ADC)
  • Safety instructions for AC500 PLCs 3ADR025003M9903
  • ABB I/O Systems - S800 I/O AI830A
  • AC500-eCo PM556-TP-ETH; PLC-eCo CPU PM556-TP-ETH 3ABD00034186
  • ABB I/O Remote Unit ICSF08D1 CS31 CS 31 Procontic FPR3323101R1012-L
  • WMDOLT2-A75(65KA)6E 1TGE106812P0001 System circuit breaker Drawer type
  • Technical analysis of ABB 1MRK002247-Apr04 protection relay module
  • PFTL101A 0.5KN 3BSE004160R1 Pressductor PillowBlock horizontal load cell
  • 3BSE004166R1 PFTL 101A-1.0kN, Load cell
  • SD Series I/O Interface cRBX01 2VAA008424R1
  • ABB 3BSC950193R1 TB850 CEX-Bus Terminator
  • LDGRB-01 3BSE013177R1 Analysis of module technology
  • GRBTU 3BSE013175R1 Communication gateway module
  • 3BHE037864R0101P UF C911 B101: CVMI2B -PROGRAMMED-
  • Panel 800 version 6
  • 3BHE024577R0101 PPC907BE ACS 2000 Drive Manuals
  • I/O Systems - 3BSE028602R1 DO880 - ABB Ability™ System
  • ABB YPP110A 3ASD573001A1 application controller
  • 57520001-FY DSCS 150 GCOM Communication Unit
  • AC 800M - Processor Modules 3BSE018157R1 PM861AK01 Processor Unit
  • 3BSE069274R1 PP877K Key Panel 10.4" Panel 800
  • 3BSE069449R1 (CI854BK01) PROFIBUS DP-V1
  • 3BSE018135R3 CI858 ABB Ability System 800xA
  • P3BSE042238R1 PANEL 800-PP846 PRE-OWNED
  • ABB NDBU-95 NDBU - DDCS branching unit
  • X10-14210201 605-A53842-002 Abaco Systems specification
  • HIMax®System Bus Module X-SB01 Manual
  • GE Intelligent PlatformsVersaMax* PLC User Manual 151X1235DB15SA03
  • MOTOROLA FLN3524/FCN6650 adapter power supply
  • SYMAP ECG Ship Monitoring And Control Panel 12-36V DC
  • 9200 and 74712 Seismoprobe Velocity Transducers
  • 3500/91 EGD Communication Gateway Module 161204-01
  • 1900/55 Fan Monitor: Operation Manual
  • 3701/55 ADAPT (ESD) Emergency Shutdown Device 323174-01
  • 3300 XL 8 mmProximity Transducer System 330104-00-05-10-02-CN
  • MR series (Melody rack) input and output›CAC 10-P 3BDH000610R1
  • 57160001-ADF DSDP 170 inc. Pos. and Speed meas.
  • S100 I/O - Modules DSDO 115K12 Digital Outp, 32 ch, 24
  • AC 400 Power SA168K16 Basic Power Supply and Switch
  • 3BSE018290R1 DSAI 133A Analog Input Board 32 Channels
  • 3BSE011180R1 Advant Controller 450 Version 2.3 PM511V08 Processor Module
  • 3BSC950164R30 S100 I/O Cables DSTK 221L3 Cable Assembly ,Ribbon Cable,
  • 3BSE020419R1 S100 I/O - Modules DSAO 120AK01 Analog Output 8 ch 12 Bit,
  • REF3BSE012545R1 CI546 VIP Communication Interface
  • 3BSE004772R1 Advant Controller 410 Version 1.5 Communication Modules
  • AC 400 - Communication Modules 3BSE018283R1 CI522A
  • Bently Nevada 3500/05-01-03-00-00-00 Rack Module
  • 3500 Series Status System Bently Nevada 135473-01 Vibration Monitoring Module
  • 330130-045-00-00 Bently Nevada 3300 XL Extension Cable
  • Bently Nevada 330100-90-01 3300 XL 8 mmProximity Transducer System
  • Bently Nevada 149369-01 Key components of 3500 mechanical protection system
  • 106M1081-01 Universal AC Power Input Module Description
  • PR6423 8mm Eddy Current Sensor
  • PR6424 16mm Eddy Current Sensor
  • VIBRO-METER 200-560-000-112 Communication board
  • VIBRO-METER 200-510-111-035 Mechanical protection card
  • Bently Nevada 22810-01-05-50-02 Stop production status confirmation
  • 330180-91-05 Bently Nevada 5/8 mm Proximitor Sensor
  • HIEE300690R0001 AR C093 AE01 Relay Output Card
  • Multilin UR Family Proven, State-of-the-Art Protection & Control Systems
  • Multilin 8 Series Innovative protection and control relay platform
  • Multilin 3 Series Intuitive industrial and utility protective relays for feeders, motors and transformers
  • MVME177P TM Single-Board Computer MOTOROLA
  • ABB DRIVE SERVICES Spare Parts Service product description
  • Cradlepoint IBR200 Product life cycle announcement
  • CC PUIO3 series Honeywell CC-PAOH01 analog output module
  • Honeywell TC-OAV081 Analog output module p/n 97062778
  • Honeywell TC-PRR021 Redundant module DHL, UPS fast delivery
  • Honeywell TC-FXX102 TC-FX10210 controller
  • Honeywell TK-PRS021 C200 Product overview
  • Honeywell ML6420A3007-E master controller
  • Parts on HONEYWELL automaton S4560M S4560M1036 boiler-Diesel boiler
  • Honeywell PK 81181 Installation Instructions for the
  • Honeywell 2MLR-CPUH/F-CC MasterLogic-200 Specifications and Technical Data
  • 3BSE018161R1 PM864AK01 Processor Unit ABB
  • ABB 3BHE017628R0102 PPD115A102 club.
  • FANUC WHEDCO 78004655 System controller module
  • FANUC WHEDCO 78004661 Analysis I/O module