Danger warnings
The following information is for your personal safety and the prevention of damage to the device described or connected devices. Safety instructions and warnings for the prevention of danger to the life and health of users or service personnel, and for the prevention of damage are highlighted in this document by the following pictograms.
These consist of “Warning” and “Information” pictograms. Warnings indicate the following: Death, serious injury or substantial material damage may occur if the related safety measures are not implemented. The individual “Warning” pictograms have the following meaning:
CAUTION ! (general) An instruction to be observed in order to ensure protection against hazards and the safe operation of the device. The specified procedure should be observed.
CAUTION! Electric shock! Persons may be exposed to dangerous voltages that occur in electrical systems. There is a danger of electric shock if a live part is touched.
CAUTION ! Observe ESD measures! Electrostatic discharge may destroy electronic components.
Information pictograms indicate the following: Important information about the product or the relevant section of the document, requiring the particular attention of the reader. The “Information” pictogram has the following meaning: Description of important information. Tips, to simplify operations.
The Micro Panel GF-1 a visualisation unit that is provided with touch zone functions for medium to high complexity automation systems, meeting all the requirements placed on a modern visualisation unit. The Micro Panel GF-1 must be loaded before use with the appropriate project data. This is stored in the external plug-in memory card (PC card). The memory card in the GF-1 can be loaded with project data via a download or directly on the PC (PC card slot). The project data is created using the design software for the GF-1 device series (GALILEO). The Micro Panel GF-1 provides two slots for communication modules or system expansions (→ Section 11). The communication card handles the connection to the automation system. They are described in separate documentation. This device description is a reference for technical data, information on installing, terminals, commissioning and operating all the versions of the Micro Panel GF-1. The illustrations in this documentation refer to the 10“-Version (→ Section 2), unless otherwise noted. Lettering and function of the terminals and indicators are the same for all device versions.
The Micro Panel GF-1 is available in different device versions. They differ on the whole by the size of the used flatpanel display with corresponding device size, as well as the kind of supply voltage.
The following components are supplied with the basic equipment : Micro Panel GF-1 including PC-Card retaining device and a blind plate with knurled screws for System Slot 1
• Fixing screws for device installation (4 pcs.)
• Seal for device installation
• Power supply plug - DC Version (GF1-xxxxD) : plug-in screw terminal (3 pole)(Poenix, Type : MSTB 2.5/3-ST-5.08) - AC Version (GF1-xxxxA) : Standard appliance plug
• Device description
The Micro Panel GF1 series comes in different mounting versions. The front panel version with 4 fixing holes (xx0) is specially designed for mounting in an enclosure or cabinet where there is no possibility of access from the rear. It is fixed from the front with four countersunk screws through the front plate (→ Section 5). The front versions with threaded bolts at the back require access from the rear. Washers and nuts are used to mount the device from the rear. All mounting versions ensure a sealed mounting to IP65. The relevant mounting instructions must be observed (→ Section 5.2). Ensure that the mounting allows access to connections, status LEDs, operating elements, such as the Download button and the memory card (PC card). Ensure sufficient space for outgoing cables (connector housings and bending radii of cables). The Micro Panel GF1 can be run at a maximum ambient temperature of 50°C (→ Section 21). The ambient temperature refers to the air temperature in the vicinity of the lower cooling slots, with vertical mounting, unobstructed air convection and a maximum operating altitude of 2000m above sea level. When mounting in an enclosure or cabinet, the ambient temperature is likewise the air temperature inside the enclosure concerned. In this case it is assumed that the air temperature at the front of the device is not higher than the temperature in the enclosure or cabinet, and there is no additional heat caused by radiation or conduction that has an effect on the device. The cooling slots must always be free in order to ensure the proper cooling of the system. Ensure a wall clearance of at least 3 cm on all sides of the housing, so that proper air circulation is not impaired. Avoid exposure to direct sunlight on the flat screen, even when it is switched off. The sunlight (UV component) and the resulting heat may damage the display.