KONG -Y
NameDescriptionContent
Location:
product
HONEYWELL 8C-PCNT01 51454363-175 -1 Series 8 Controller and I/O Specification
❤ Add to collection

HONEYWELL 8C-PCNT01 51454363-175 -1 Series 8 Controller and I/O Specification

HONEYWELL-8C-PCNT01-51454363-175-1

U.S.$8520.00
U.S.$75000.00
U.S.$71250.00
U.S.$69750.00
Weight:0.900KG
Quantity:
(Inventory: 99999)
Buy now
Add to cart
Description

HONEYWELL-8C-PCNT01-51454363-175-1


HONEYWELL 8C-PCNT01 51454363-175 -1 Series 8 Controller and I/O Specification

Detail description

The Experion Series 8 C300 controller forms the heart of the Experion control system and deterministically executes controlstrategies, batch operations, interfaces to local and remote I/O and directly hosts custom programmable applications. 

The compact controller design does not require any additional Interface / communication modules and all control execution andcommunications are contained in the controller module.

The C300 controller runs the filed proven, deterministic Control Execution Environment (CEE) which is the core C300software that provides powerful and robust control for the distributed control system (DCS). The control strategies areconfigured and loaded to the C300 controller through the Control Builder, an easy and intuitive engineering tool.

The C300 Controller is constructed using the Series 8 form factor that employs an Input Output Termination Assembly(IOTA) and an electronics module which mounts and connects to the IOTA. One C300 Controller module and its IOTAcontains all of the control and communication functionalities. The C300 IOTA contains only passive devices such asFTE address switches, FTE cable connectors and I/O Link cable connectors. Figure 1 below depicts the IOTAcomponents.

The C300 Controller may operate in both non-redundant and redundant configurations. Redundant operation require asecond identical controller with its own IOTA and connecting redundancy cable. The C300 Controller supports Series 8I/O modules. Two IO Link interfaces, which are redundant, provide connection between the C300 controller andassociated I/O modules. The IO Link interface connectors are on the C300 IOTA. 

The C300 CEE provides an execution and scheduling environment in which Control Modules (CMs) and Sequential Control Modules (SCMs) execute user-configured control strategies. The CEE also support peer to peer communications with other C300 controllers and communication modules like Foundation Fieldbus and Profibus. The C300 CEE is configured using the Control Builder Engineering environment. The Control builder provides a graphical engineering environment where engineers can configure the Experion system and create control strategies by using the various function blocks available in the Library. The C300 CEE based control strategies can be configured with minimum execution rates of 50 msec.

Overview and Features Series 8 features an innovative design that supports enhanced heat management. This unique look provides a significant reduction in overall size for the equivalent function. Both Series 8 IOM and IOTA are available with Conformal Coated feature. The term ‘Coated’ stands for hardware with conformal coating material applied to electronic circuitry for protection against moisture, dust, chemicals, and temperature extremes. Coated IOM and IOTA are recommended when electronics must withstand harsh environments and need

 to have added protection. The unique features of the Series 8 I/O include: • I/O Module and field terminations are combined in the same area. The I/O Module is plugged into the IOTA to eliminate the need for a separate chassis to hold the electronics assemblies • Two level “detachable” terminals for landing the field wiring in the enclosure, providing easier plant installation and maintenance • Field power can be supplied through the IOTA, with no need for extra power supplies and the associated craft wired marshalling • Redundancy is available directly on the IOTA without any external cabling or redundancy control devices, by simply adding a second IOM to an IOTA • The innovative styling is one of its unique features. This styling includes features to facilitate the effective use of control hardware in a systems environment. These features include: o Vertical mounting for more effective wiring since most field wiring applications require entry from the top or bottom of the systems cabinet o An “information circle” for a quick visual cue to draw the Maintenance Technician’s eye to important status information o “Tilted” design for effective heat management within the cabinet enclosure. Since Series C allows for a significant increase in cabinet density, an effective heat management system is critical for high systems availability o Input and output circuits are protected from shorts to alleviate the need for in-line fusing, reducing installation and maintenance costs Series 8 IOTAs combine multiple functions into a single piece of equipment: o Single and redundant configurations o On-board termination of process signals o On-board signal conditioning o On-board connection to appropriate networks (FTE, I/O LINK) o Field power distribution without external marshalling o IOM plugs into the IOTA and receives power from the IOTA o The IOTA receives its power through cables from header board I/O Module Functions 

• High Level Analog Input /HART Input Module (16pt) 

The High Level Analog Input Module supports both high level analog and HART inputs. Analog inputs are typically 4-20mA DC for both traditional and HART devices. HART data can be used for status and configuration. HART data, such as the secondary and tertiary variables, can also be used as process control variables. Two versions Single ended and Differential type are available. 

• High Level Analog Input w/o HART (16pt) – The High Level Analog Input Module supports high level analog inputs Analog inputs are typically 4-20mA DC for traditional devices. 

• Analog Output/HART Output Module (16pt) – The Analog Output Module supports both standard 4-20mA DC outputs and HART transmitter outputs. 

• Analog Output w/o HART (16pt) 

– The Analog Output Module supports standard 4-20mA DC outputs. 

• Digital Input 24 VDC (32pt) – Digital input sensing for 24V signals 

• Digital Input Sequence of Events (32pt) – Accepts 24VDC discrete signals as discrete inputs. 

The inputs can be time tagged to support 1ms resolution Sequence of Events. 

• Digital Input Pulse Accumulation (32pt) – Accepts 24VDC discrete signals as discrete inputs. 

The first 16 channels can be configured as Pulse accumulation to support Pulse Accumulation and frequency measurement on per channel basis. Channels 17 – 32 can be configured as DI. 

• Digital Output 24 VDC (32pt) – Current sinking digital outputs. Outputs are electronically short-circuit protected. 

• DO Relay Extension Board (32pt) – Digital output with NO or NC dry contacts. It can be used for low power or high power applications. 

• Low Level Analog Input – RTD & TC (16pt) – Provides thermocouple (TC) and resistance temperature device (RTD) inputs. 4.3. Series 8 I/O Sizing In virtually all configurations, the C300 controller and Series 8 I/O provides useful, maintainable process equipment connections in a smaller footprint than existing competitors and Honeywell equivalent products. Installing Series 8 I/O modules contributes to overall total installed cost savings. IOTA sizes vary based on the application. In general, an analog module has 16 points and resides on a 6 inch (152mm) IOTA for non-redundant applications and a 12 inch (304mm) IOTA for redundant applications. A discrete module has 32 points and resides on a 9-inch (228mm) IOTA for non-redundant applications and a 12 inch (304mm) IOTA for redundant applications. Specific information on the size of a particular module is described in the Model Number Table. 4.3.1. Series 8 Field connections Series 8 Field connections use a standard modular connector. 

The connector modularity allows for removal and insertion of the field wiring. This significantly reduces installation and maintenance procedures and can assist in field check out. Series 8 field connectors accept up to 12 AWG / 2.5 mm2 stranded wire.

IOTA Sizing is nominal (6in = 152mm, 9in =228mm, 12in =304mm). I/O modules are associated with their respective IOTAs in the table below. The I/O Module is supported by one or more IOTAs. Below section also provides an overview of various available IO modules, IOTA, IOTA size and redundancy features.

Specifications for Series 8 I/O Specifications for Series 8 I/O modules are shown below. 

4.4.1. Analog Input with HART - Differential Function Analog Input Module accepts high level current or voltage inputs from transmitters and sensing devices. Notable Features 

• Extensive self-diagnostics 

• Optional redundancy 

• Supports either Single Ended / Differential Inputs 

• HART-capable, multivariable instruments and multiple modems for fast collection of control variables 

• Fast loop scan

Function The Analog Input Module accepts high level current inputs from transmitters and sensing devices. Notable Features 

• Extensive self-diagnostics 

• Optional redundancy 

• HART-capable, multivariable devices 

• Fast loop scan • Internal or external field power selection 

• On board excitation power (no need for marshalling power) 

• Suitable for Configure / Status for HART Device 

• Galvanic Isolation

The Analog Input Module accepts high level current inputs from transmitters and sensing devices. Notable Features 

• Extensive self-diagnostics 

• Optional redundancy 

• Fast loop scan 

• Internal or external field power selection 

• On board excitation power (no need for marshalling power) 

• Galvanic Isolation (System to Field only with external user supplied power)

The Low Level Analog Input (LLAI) Module accepts up to 16 channels of temperature inputs from RTD & TC. Notable Features 

• TC and RTD operation 

• Remote Cold Junction compensation capability 

• 1 Second PV scanning with OTD protection 

• Configurable OTD protection (See below) 

• Temperature points can be added in 16 point increments Temperature Support The Temperature variable is collected from all points at a 1 second rate. 

The 1 second update includes a configurable check for Open Thermocouple Detection (OTD) (see below) before propagation of the temperature variable. All TC inputs include integral Cold Junction Compensation (CJC). Sampling and Open Sensor Detect The TC/RTD IOM supports a configuration parameter for Open Sensor Detect before PV delivery. With the OTD configuration active, the PV is sampled and held while an OTD cycle is performed within the same measurement window. If the OTD is negative, the PV is propagated up through the system. If the OTD is positive, the PV is set to NAN and the input channel soft failure is set. In this way, no inappropriate control action occurs for PV values that are invalid due to an open thermocouple. PV sampling/reporting incurs no added delays from OTD processing



Xiamen kongjiang automation technology co., ltd is a technology-based entity company established on may 11th, 2017, located in Xiamen, Fujian province. 

The company is mainly engaged in the sales of imported industrial control parts, electrical engineering design, installation, programming, debugging, construction and other businesses. The company has an experienced and well-trained technical team, which is committed to providing customers with services such as electrical automation system development, automatic upgrading and transformation of the original production line, energy-saving transformation and production of complete sets of electric control cabinets.

The company's main products and services include DCS/PLC system accessories, automation products, electrical equipment sales, computer software and hardware and auxiliary equipment wholesale. Since its establishment, the company has been adhering to the tenet of "honesty, pragmatism and innovation" and applied advanced automation technology, computer technology, sensing technology, frequency conversion technology, servo technology and industrial network technology to provide quality services for many enterprises such as food, machinery, papermaking, stone, water treatment and biotechnology.

The registered capital of the company is 3 million yuan, and the enterprise type is limited liability company (natural person investment or holding). The company has a dynamic and skilled team and maintains good cooperative relations with many well-known enterprises.

Please note that the above information may change with time. Please refer to the latest information published by official website or relevant authorities.

Related models

CMA131 3DDE300411

PDD205A0121

FS450R12KE3/AGDR-71C

CS513 3BSE000435R1

UNS2881b-P,V1 3BHE009319R0001

A30-30-10RT

5SHY6545L0001 AC10272001R0101 5SXE10-0181

PPC380AE01 HIEE300885R0001

5SDF1045H0002

5SHX2645L0004 3BHL000389P0104 3BHB003154R0101 5SXE05-0156

DSTC175 57310001-KN

SCYC51010 58052515G

RB520 3BSE003528R1


  • 81EU50 83SR50 88TK50 Universal I/O and control modules 丨ABB
  • GJR2390200R1411 83SR04R1411 Control Module Universal
  • ABB INSUMMCU2 MCU2A02V24 INSUM® PROFIBUS Gateway Manual SW 2.1
  • ABB REF542 series 1VCR007346 G0028 Function and configuration
  • ABB 216AB61 HESG324013R101 Control Panel-Specifications
  • ABB 216EA61B HESG448230R1/G
  • 216VC62A HESG324442R112/F 丨ABB
  • 500PSM03A 1MRB150038R1 series丨ABB Power control panel
  • REG216, CompactREC216 Numerical Generator ProtectionNumerical Control Unit
  • ABB Panel 800 series 3BSE092980R1 PP886 Standard Panel 15"
  • 500CIM05 1MRB150077R1/B ABB
  • 500CPU05 1MRB150081R1/E ABB-Module
  • 500SCM01 1MRB200059/C 1MRB15004R0001丨ABB Star coupler module
  • ABB SYNCHROTACT ® 5
  • ABB 3BHB006716R0277 SYN 5302a-Z,V277: Auto dual channel Syn
  • ABB Pressductor-PillowBlock Load cells series PFCL201
  • ABB UNS4684A-P,V.1 HIEE305114R00R0001 control panel
  • Tension Electronics PFEA 111, 112, 122 and 113 丨ABB
  • ABB PFRL101C-1.0KN 3BSE023316R1002 Web Tension Measurement
  • 1VCF750090804 HMI SUE 3000 (110...220 V) ABB
  • 57120001-AT DSAO 110 ABB
  • S100 I/O Modules DSAO 120 57120001-EY 丨ABB
  • Advant Controller 500 series 500BIO01 1MRB150005R0001 1MRB200060/E ABB
  • 3BHE023784R2530 PP D113 B01-25-111000: AC 800PEC Static Excitation Systems›UNITROL 6000 X-power
  • ABB EXC3BSE008105R1 SC560 Exchange
  • HR Series Turbine control systems SD Series remote I/O ABB
  • HR Series (Harmony Rack) I/O RSPASI23
  • ABB SPBRC400 Controller with Expanded Memory
  • E3HAB8101-18 Modules Drive System 丨ABB
  • ABB 3BHL000986P7000 LXN 1604-6, 27V 500W
  • ABB REF615_series_ Feeder protection and control
  • ACS 6000 series Medium voltage AC drives for control of 3–27 MW motors up to 3.3 kV
  • I/O Systems - S800 I/O series-ABB
  • SPAJ 140 C Series ABB
  • INCLUDING PFSK 113 7625013-S 丨ABB
  • AC 800PEC The high-performance control system for model-based design
  • HKQCS PARTS ON LINE 129740-002 ABB
  • UNITROL 6000 X-power 3BH022294R0103 GFD233A103
  • AO810 AO810V2 - ABB Ability™ System 800xA® hardware
  • Elastimold® molded vacuum reclosers – MVR MVR 0.44-10KA
  • AC 800M series PM865 3BSE030193R1 discontinued products
  • 1MRK000838-HA ABB RXIDK 2H series
  • ABB 605 series
  • Feeder protection REJ601 BD446NN1XG
  • ABB SAFT183VMC expansion module board unit specifications
  • 3BHB004661R0101 KU C711 AE; GATE UNIT POWER S GUSP
  • PRC3BSE066490R1 PM856AK01 Processor Unit
  • SM560-S (1SAP280000R0001) AC500 CPU Firmware SM560-S-FD-4
  • 769137 Detector 13CO2 10% (Uras26) ABB control unit
  • AC500 CPU Firmware
  • 0002-07-2-00001-01 BMXS Science Module (ADC)
  • Safety instructions for AC500 PLCs 3ADR025003M9903
  • ABB I/O Systems - S800 I/O AI830A
  • AC500-eCo PM556-TP-ETH; PLC-eCo CPU PM556-TP-ETH 3ABD00034186
  • ABB I/O Remote Unit ICSF08D1 CS31 CS 31 Procontic FPR3323101R1012-L
  • WMDOLT2-A75(65KA)6E 1TGE106812P0001 System circuit breaker Drawer type
  • Technical analysis of ABB 1MRK002247-Apr04 protection relay module
  • PFTL101A 0.5KN 3BSE004160R1 Pressductor PillowBlock horizontal load cell
  • 3BSE004166R1 PFTL 101A-1.0kN, Load cell
  • SD Series I/O Interface cRBX01 2VAA008424R1
  • ABB 3BSC950193R1 TB850 CEX-Bus Terminator
  • LDGRB-01 3BSE013177R1 Analysis of module technology
  • GRBTU 3BSE013175R1 Communication gateway module
  • 3BHE037864R0101P UF C911 B101: CVMI2B -PROGRAMMED-
  • Panel 800 version 6
  • 3BHE024577R0101 PPC907BE ACS 2000 Drive Manuals
  • I/O Systems - 3BSE028602R1 DO880 - ABB Ability™ System
  • ABB YPP110A 3ASD573001A1 application controller
  • 57520001-FY DSCS 150 GCOM Communication Unit
  • AC 800M - Processor Modules 3BSE018157R1 PM861AK01 Processor Unit
  • 3BSE069274R1 PP877K Key Panel 10.4" Panel 800
  • 3BSE069449R1 (CI854BK01) PROFIBUS DP-V1
  • 3BSE018135R3 CI858 ABB Ability System 800xA
  • P3BSE042238R1 PANEL 800-PP846 PRE-OWNED
  • ABB NDBU-95 NDBU - DDCS branching unit
  • X10-14210201 605-A53842-002 Abaco Systems specification
  • HIMax®System Bus Module X-SB01 Manual
  • GE Intelligent PlatformsVersaMax* PLC User Manual 151X1235DB15SA03
  • MOTOROLA FLN3524/FCN6650 adapter power supply
  • SYMAP ECG Ship Monitoring And Control Panel 12-36V DC
  • 9200 and 74712 Seismoprobe Velocity Transducers
  • 3500/91 EGD Communication Gateway Module 161204-01
  • 1900/55 Fan Monitor: Operation Manual
  • 3701/55 ADAPT (ESD) Emergency Shutdown Device 323174-01
  • 3300 XL 8 mmProximity Transducer System 330104-00-05-10-02-CN
  • MR series (Melody rack) input and output›CAC 10-P 3BDH000610R1
  • 57160001-ADF DSDP 170 inc. Pos. and Speed meas.
  • S100 I/O - Modules DSDO 115K12 Digital Outp, 32 ch, 24
  • AC 400 Power SA168K16 Basic Power Supply and Switch
  • 3BSE018290R1 DSAI 133A Analog Input Board 32 Channels
  • 3BSE011180R1 Advant Controller 450 Version 2.3 PM511V08 Processor Module
  • 3BSC950164R30 S100 I/O Cables DSTK 221L3 Cable Assembly ,Ribbon Cable,
  • 3BSE020419R1 S100 I/O - Modules DSAO 120AK01 Analog Output 8 ch 12 Bit,
  • REF3BSE012545R1 CI546 VIP Communication Interface
  • 3BSE004772R1 Advant Controller 410 Version 1.5 Communication Modules
  • AC 400 - Communication Modules 3BSE018283R1 CI522A
  • Bently Nevada 3500/05-01-03-00-00-00 Rack Module
  • 3500 Series Status System Bently Nevada 135473-01 Vibration Monitoring Module
  • 330130-045-00-00 Bently Nevada 3300 XL Extension Cable
  • Bently Nevada 330100-90-01 3300 XL 8 mmProximity Transducer System
  • Bently Nevada 149369-01 Key components of 3500 mechanical protection system
  • 106M1081-01 Universal AC Power Input Module Description
  • PR6423 8mm Eddy Current Sensor
  • PR6424 16mm Eddy Current Sensor
  • VIBRO-METER 200-560-000-112 Communication board
  • VIBRO-METER 200-510-111-035 Mechanical protection card
  • Bently Nevada 22810-01-05-50-02 Stop production status confirmation
  • 330180-91-05 Bently Nevada 5/8 mm Proximitor Sensor
  • HIEE300690R0001 AR C093 AE01 Relay Output Card
  • Multilin UR Family Proven, State-of-the-Art Protection & Control Systems
  • Multilin 8 Series Innovative protection and control relay platform
  • Multilin 3 Series Intuitive industrial and utility protective relays for feeders, motors and transformers
  • MVME177P TM Single-Board Computer MOTOROLA
  • ABB DRIVE SERVICES Spare Parts Service product description
  • Cradlepoint IBR200 Product life cycle announcement
  • CC PUIO3 series Honeywell CC-PAOH01 analog output module
  • Honeywell TC-OAV081 Analog output module p/n 97062778
  • Honeywell TC-PRR021 Redundant module DHL, UPS fast delivery
  • Honeywell TC-FXX102 TC-FX10210 controller
  • Honeywell TK-PRS021 C200 Product overview
  • Honeywell ML6420A3007-E master controller
  • Parts on HONEYWELL automaton S4560M S4560M1036 boiler-Diesel boiler
  • Honeywell PK 81181 Installation Instructions for the
  • Honeywell 2MLR-CPUH/F-CC MasterLogic-200 Specifications and Technical Data
  • 3BSE018161R1 PM864AK01 Processor Unit ABB
  • ABB 3BHE017628R0102 PPD115A102 club.
  • FANUC WHEDCO 78004655 System controller module
  • FANUC WHEDCO 78004661 Analysis I/O module