KONG -Y
NameDescriptionContent
Location:
product
IS200BPIHH1A Manufacturer General Electric Country
❤ Add to collection

IS200BPIHH1A Manufacturer General Electric Country

IS200BPIHH1A
U.S.$6498.00
U.S.$552.00
U.S.$524.40
U.S.$513.36
Weight:0.000KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200BPIHH1A

Part Number IS200BPIHH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200BPIHH1A is a Bridge Personality Interface Board designed and developed by GE. The product is developed under the Drive Control series. It connects into a CABP board where it communicates through that and other boards. The BPIH board buffers control signals for the BICH board before they interface with the fiber-optic array. The board's subassembly acts as an RS-422 interface distributor for phase-related signals as they come and go from the BICH and FOSB boards. The Control Assembly Backplane links to the BPIH board, which communicates with the Bridge Interface and Control Board via CABP board signal routes. It is an auxiliary board that works with the larger Control Assembly backplane. All phase-related signals coming from or going to the FOSB or BICH boards can be interfaced and distributed by this board. This is accomplished using a fiber-optic array and twisted pairs with differential signaling. Features The majority of the board's bridge inputs/outputs (I/O) are routed to the Fiber-Optic Interface Board via the BPIH board subassembly. This is accomplished on a phase-by-phase basis using three identical wires dedicated to phase A, B, and C signals. It is intended to communicate with the (BICH) H-Bridge Interface and Control Board via the Control Assembly Backplane. The Bridge Interface and Control board's bridge routes much of the Input/Output to the FOSB Fiber-Optic Interface board via the subassembly. The board has two backplane connectors. These are denoted by the letters P1 and P2. The board also has three additional connectors labeled JA through JC. These are BPIH subassembly plug connectors that mount into the faceplate connected to the circuit board. 

The board has a line of eighteen integrated circuits with a final integrated circuit near the board's center. TPC, TPX, TPB, and TPA are the designations for four sets of plated through-holes on the board. The front panels of the BICH board and BPIH board subassemblies contain high-density shielded connectors for these cables, ensuring shield continuity to the board rack chassis. On the BPIH board subassembly, control signals are buffered and interfaced with the FOSB board fiber-optic array through twisted pairs with differential signaling. Singular high-speed signals (such as VCO feedbacks) are terminated by a termination resistor at the receiving end. The RS-422 interface and distributor for all phase-related signals going to or coming from the BICH and FOSB boards is the BPIH board subassembly. BPIH is a subassembly on the Control Assembly Backplane that is commonly used as an auxiliary board. This board communicates with the BICH H bridge interface via three identical cables. Communication is done on a phase-by-phase basis (A/B/C). It is designed to fit into an Innovation series rack system. The Innovation Series is intended to fit into specific rack slots. Placing the board in the wrong slot may cause damage to the board or its components. Adhere to all replacement procedures outlined by the manufacturer in publications such as data sheets and manuals. If these publications are no longer available, this information is available in GE publication GEI-100417. Application Data There are no fuses, test points, LED indicators, or adjustable hardware on the BPIH board subassembly. There are three plug connectors (JA, JB, and JC) and two backplane connectors on the BPIH board subassembly (P1 and P2). Installation Procedure Place the board in the appropriate slot on the board rack. Because the Innovation Series boards/modules are built for certain rack spaces, placing the BPIH board subassembly into the incorrect slot can cause electronics damage. Begin seating the board by firmly pressing the top and bottom of the faceplate with your thumbs at the same time. Tighten the screws at the top and bottom of the faceplate to finish seating the board in the slot. To verify that the board is positioned squarely, tighten the screws evenly. Reconnect any electrical connections that were severed during step 3 of the board removal process. Snap the control cabinet door shut. Software In a ladder diagram format, application software is executed sequentially and represented in its dynamic state. Maintenance personnel have the ability to add, delete, or change analog loops, sequencing logic, tuning constants, and so on. To simplify editing, data points can be selected and dragged on the screen from one block to another. Other features include logic forcing, analog forcing, and frame rate trending. The documentation for application software is generated directly from the source code and printed on-site. 

This includes the primary elementary diagram, I/O assignments, tuning constant settings, and so on. The software maintenance tools are available in the HMI as well as as a separate software package for almost any Windows 95 or NT-based PC. System IONet Addressing The DHCP servers in the controllers assign IP addresses to IONet devices. 

The Host ID presented to the DHCP server is determined by the board type and serial number information stored on the terminal board's serial EEPROM. The I/O module can be replaced without having to update the toolbox or controller communication IDs because the Host ID is part of the terminal board. When replacing a terminal board, the user must associate the new Host ID with the configured device. To make this process easier, ToolboxST displays a list of unidentified devices that have requested IP addresses. When connecting an I/O pack to a main controller, IONet should only pass through five switches in series. Any configured IONet port on a controller or I/O module is constantly sending data, allowing the detection of faulty network cables, switches, or board components to occur immediately. When a fault occurs, the controller or I/O module generates a diagnostic alarm. IONets are class C networks. Each is its own network with its own set of subnet addresses. 

The IONet IP host addresses for the controllers are fixed. The ToolboxST assigns IP addresses to the I/O packs, and the controller automatically distributes the addresses to the I/O packs via a standard Dynamic Host Configuration Protocol (DHCP) server in the controllers. Output Processing The system outputs are the portions of calculated data that are transferred to external hardware interfaces and then to the various actuators that control the process. The output voting hardware votes on TMR outputs. Through simplex hardware, any system can output individual signals. 

The TMR system outputs are calculated independently by the three voting controllers. Each controller sends output to the I/O hardware associated with it (for example, the R controller sends output to the R I/O). A voting mechanism then combines the three independent outputs into a single output. Different signal types necessitate distinct methods for determining the voted value. Circuit Protection Fault current protection limits the current to what the system components can handle. Feedback from the branch circuit system Protection against ground faults in floating systems If possible, redundant applications Systems with multiple power applications run the risk of applying the incorrect power to a load or interconnecting power buses. To avoid this issue, the component employs specific connector conventions. Existing terminal board designs pose the greatest risk of incorrect connection. Regardless of whether the connection is AC or DC, these boards use a three-position Mate-N-Lok for power input. In addition, the existing boards have two parallel connectors for power daisy-chain wiring within a panel.BICH TO FOSB INTERFA

  • Tricon 8120E card is in stock.
  • NE870 Network Router ABB 3BSE080239R1
  • ALSTOM V4561484-0100 Amplifier Module Rev 7 Pcb Circuit Board
  • Model 10959-201 and -203 Wall-Mount Audio Messenger Interfaces
  • HIMA X-SB 01985210207 24VDC System bus module
  • HIMA X-FAN 18 03 High-efficiency cooling plate fan
  • HIMatrix F3 AIO8/4 01 HIMA Compact Controller
  • 3BHE039770R0102 PP D539 A102: AC 800PEC Contr. Device
  • ABB CMC 70, Controller, SW-Vers. 1.61/2.11
  • GE SR760-CASE 750/760Feeder Management Relay® Instruction Manual
  • ABB REG670 C30 Version 2.0 General Information
  • REF543KM127BAAA ABB FEEDER TERMINAL
  • Danaher driver SAM-DA-400/480-07N-P4N-F
  • GE FANUC/ALSTOM LC106-1- LE108 LC105 LC106 Spot model
  • ALSTOM AB121丨AY00000000266/B technical parameter
  • GE ALSTOM LE109A-1 control card data
  • GE ALSTOM IR139-1丨063022350 丨80801419 Control card. data
  • Alstom Control Set-UT150-1 Kongjiang-spot
  • ALSTOM AL132丨AL132A Control Card
  • PM1118丨ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • DEIF DLQ72-PC-PY ROLLS-ROYCE K85240 PITCH INDICATOR 10V
  • Rolls-Royce Marine R10I53S/R10I53S Panel Computer 98H0101A0000I Rev 1.9
  • ROLLS-ROYCE P001240-1 display REV 2
  • ROLLS-ROYCE RRDIO15 I/O ALARM MODULE
  • Rolls-royce UN930 Digital Display Controller 24V
  • ROLLS-ROYCE MARINE LAUER LCA 325.P2 PROFIBUS-DP NET DISPLAY PANEL UN924
  • ROLLS-ROYCE MARINE AS 5880-PC1002 STEERING GEARS-TENFJORD PCB card
  • ROLLS-ROYCE UN31 ECR panel 000127603
  • Rolls-royce ship AS UN991.1 distributing plate
  • ROLLS-ROYCE 5045 K THRUSTER CONTROLLER PANEL
  • Rolls-Royce SLIO 02 Canman controller network
  • Rolls-Royce E-1071 automatically displays 07918 B UN 921 ECR 24VDC
  • ROLLS ROYCE PCC1030C ULSTEIN panel controller card
  • ROLLS-ROYCE KAMEWA PROPELLERS control room panel basic R160637A
  • ROLLS-ROYCE UN925 Panel Controller
  • Rolls-royce Marine AS UN921 OPRETOR panel
  • Rolls-Royce Marine r10I53s/R10I53S Panel Computer 98H0101A0000I
  • ROLLS-ROYCE H1111.0104 ocean controller P/N:75669
  • Rolls-Royce H1111.0203 Marine Controller Version 2.2
  • Rolls-Royce H1111.0102 Marine Controller
  • Rolls-Royce H1127-0101 Marine Controller 00068308H6045/433
  • Rolls-Royce H1111.0103 Marine Controller 75669 Version 2.2
  • EMERSON KJ3221X1-BA2 VE4035S2B1 ATEX Instruction Sheet
  • EMERSON VE4017P0 M-series FOUNDATION™ Fieldbus I/O
  • A6740 16-Channel Output Relay Module for the AMS 6500 Machinery Health Monitor
  • EMERSON A6120 Protection Cards for AMS 6500 Classic Systems
  • A6000 series A6125 electric vibration monitor Emerson
  • EMERSON A6000 series control card A6410
  • EMERSON A6370 Overspeed Protection Monitor
  • ABB 3BHB015651P0001 DKTFM418B Power converter assembly
  • Westingouse Ovation 5X00500G01 Speed detector module
  • Emerson 5X00875G01 Analog input EMOD module
  • UNIOP ETT-VGA-0045 HMI touch unit with colour graphic display and VGA resolution. Available with high-quality TFT
  • General Electric Mark VI series IS200JPDBG1A IS200JPDBG1ABB printed circuit
  • General electric IS200EDISG1A distribution board
  • IS400TDBTH6A Mark* VIe control system Extended product life cycle description
  • DS200DCFBG1BLC General Electric Power Supply Board
  • 5485C Velocity Sensor Metrix
  • ABB 3BSE031155R1 BC810K02 CEX-bus Interconnection Unit
  • DCS602-0250-51-15 ABB DCS 600 Overload Capability
  • DCS602-0520-51/15 ABB Permanent drive
  • 853-032776-001 Lam Research Paddle Lifter
  • Modbus Plus Communication Module MVI56-MBP
  • PLC board (head) module KEBA CPU IP70
  • DS200DSFBG1A Driver/Shunt Feedback Board technical specifications
  • DS200DPCAG1ADB IOS + Power Connect Board Technical Specifications
  • DS200DPCAG1A IOS & Power Connect Card Assembly
  • Hirschmann MM20-P9P9T1T1SAHH Media Converters
  • Hirschmann MM20-P9P9P9P9SAHH In installation instructions
  • Hirschmann MM4-2TX/SFP Media Converters
  • Hirschmann MM4-4TXSFP-datasheet
  • Hirschmann MM3-1FXL23TX1_techdata MM3-1FXL2/3TX1
  • Hirschmann MM3-4FXS2 PowerMICE series industrial switch products
  • Hirschmann MM3-2FXS2/2TX1 Media Converters
  • MM3-1FXM2/3TX1 Hirschmann Ethernet & Communication Modules
  • Hirschmann MM3-4TX5 Media module
  • Hirschman MM2-2FXM3/2TX1 Media Module article will analyze the technical features of this product in detail
  • Hirschmann MM2-4TX1 Performance parameters of compact and modular managed Ethernet switch
  • MS4128-L3E ATEX Power mouse, modular, managed industrial Ethernet switch
  • Hirschmann MS4128-L2P ATEX 943009101, Power MICE, modular, managed Industrial
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SAHH
  • Hirschmann MM20-T1T1T1T1SZHH Managed Ethernet switch
  • Hirschmann MM20-M4T1T1T1SAHH Media converter
  • Detailed explanation of Hirschmann GMM20-mmmmmev9HHS9 xx.x.xxx Ethernet module
  • Hirschmann MM20-M2M2M2T1SAHH Management Ethernet Switch Function and Configuration Guide
  • Product introduction and technical specifications of Hirschmann MM20-M2M2M2M2EAHH media converter
  • Hirschmann MM20-M4M49999TAHH Media converter
  • Hirschmann MM20-Z6Z6Z6Z6TAHH Media converter
  • Media converter MM20-M2M29999EAHH Data
  • Media converter MM20-G2T1T1T1SAHH Hirschmann
  • Hirschmann Media converter MM20-M2T1T1T1TAHH
  • Hirschmann Ethernet module GMM GMM20-VVVVVVVVSY9HHS999.9.XX
  • Managed Ethernet Switch MM20-M4M4M4M4TAHH
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SSHH
  • Hirschmann Managed Ethernet Switch MM20-Z6Z6Z6Z6SSHH
  • Media converter MM20-T1T1T1T1TAHH Hirschmann
  • Hirschmann Media converter MM20-M4M4T1T1EAHH
  • MM20-M4M4M4M4EAHH Hirschmann Media converter
  • Hirschmann Media converter MM20-M2M2M2M2SAHH
  • Hirschmann Managed Ethernet Switch MM20-S2S2T1T1SYHH
  • ABB SDCS-POW-4 POWER SUPPLY
  • AMAT 0090-35032 ARSINE DETECTOR 0-1000PPB
  • SMC XLFD-100D-X1236 high vacuum valve 0.4 ~ 0.7MPa 5 ~ 60°C
  • 50DW412745 Control Module United Technologies Carrier
  • Carrier 50DW404638 Control module CEAS430189-02
  • TRICONEX 2481 I/O Module
  • WARNER ELECTRIC HMCS2000-PRG Programmer
  • WARNERELECTRIC MCS2000-ECA Digital control
  • Related Manuals for WAGO WAGO-I/O-IPC 758-870 and 58-873Series
  • IOC4T-RLC16 Vibro-Meter company VM600 system and sensor technical data
  • MEGGITT VIBRO-METER 200-510-076-114 VM600 MPC4 Descriptive data
  • IPC704 Signal conditioner MEGGITT VIBRO-METER IPC704 244-704-000-032 AMP
  • GSI127 galvanic separation unit MEGGITT VIBRO-METER GSI 127 244-127-000-017 A1-B02 MODULE
  • ABB Relion® 650series REC650/REL650/RET650/REB 650/REQ 650
  • Rexroth Sercos III analog, axis module R-ILB S3 AI12 AO4 SSI-IN4
  • DS200DMCBG1ABB DOS DUP Processor Board
  • DS200DMCAG1AAA Gen/Log/Key Interface Board
  • DS200DKLBG1ABB Power Connect Board
  • General Electric DS200DENCF1BDE01 EEPROM with Firmware
  • DS200DDTBG2ABB LCI Auxiliary I/O Terminal Board
  • DS200DCVAG1A DC Power and Instrumentation Board
  • DS200DCPAG1 DC Power Board GE General Electric
  • DS200DCFBG1B DC Feedback Power Supply Board
  • DS200DCFBG1AAA DC Power Feedback Board
  • DS200DACAG1 TC/DC AC/DC Convertor Board
  • DS200CVMAG3AEB Cap/Fuse Voltage Monitor Board
  • DS200CVMAG1AEB Capacitor Voltage Monitor Assembly
  • DS200CTBAG1A Analog Termination Module