KONG -Y
NameDescriptionContent
Location:
product
IS200DAMAG1B General Electric Inverter card
❤ Add to collection

IS200DAMAG1B General Electric Inverter card

IS200DAMAG1B
U.S.$7988.00
U.S.$5485.00
U.S.$5210.75
U.S.$5101.05
Weight:0.000KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200DAMAG1B

Part Number IS200DAMAG1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series EX 2100e Function Module Availability In StockIS200DAMAG1B is an inverter card developed by General Electrics. It is a part of GE drive control system. It is designed to work with a single IGBT module for the upper phase leg and a single IGBT module for the lower phase leg. 

These are typically Powerrex CM1000HA-28H IGBTs. This boards are intended to connect directly to the Bridge Personality Interface board as well as the IGBT's gate, emitter, and collector terminals. This is a Gate Drive Amplifier and Interface Board for the Innovation Series 620 frame low voltage drives. General Electric Mark VI Speedtronic systems for the management of gas and steam turbines included innovation drives. The module operates with a single IGBT module for the upper phase leg and a single IGBT module for the lower phase leg. They are typically Powerrex CM1000HA-28H IGBTs. DAMA boards are intended to link directly to the Bridge Personality Interface board as well as the IGBT's gate, emitter, and collector terminals. Features It features a dual in-line memory module (DIMM) socket for storing parameters, an Ethernet port for communication, a status indicator LED, and a built-in firmware upgrade function. The inverter card is also equipped with power semiconductors, gate drivers, and protection circuitry for controlling the flow of electrical power in the drive system. The card is designed for use in high-power applications, with a voltage rating of up to 690 volts and a current rating of up to 1700 amperes. 

The Gate Driver Amplifier and Interface Board is one of six variants. The Gate Driver Amplifiers and Interface Boards are used to connect power-switching devices (IGBTs) to the main control rack. The drive power rating is the identifier used to determine which variation of the DAM_ it is. The model has a drive power rating of six hundred and twenty frames. This board is used to amplify the current used to issue the culminating gate drive for the main drive's power bridge's on phase leg. When using this model, a fixed number of boards are used per drive. 

The board has three boards per drive, but only one board is used per phase leg. When this board is connected to the emitter, IGBT gate, collector terminals, and the Bridge Personality Interface control rack, it will connect directly to all of these. The board is modest, with only a few components installed. Four LED indicators are included (DS1 through DS4). These LEDs are either green or yellow and light up in the following patterns: When the higher IGBT is turned on, DS1 (yellow) turns on, while DS3 (green) turns off. For the bottom IGBT, DS2 (yellow) and DS4 (green) follow the same pattern. A 12-pin vertical connector and a 6-pin vertical connector are also included on the boards. Product Attributes Robust Design: Built to withstand harsh industrial environments, with a rugged construction and high resistance to temperature, vibration, and humidity. 

Versatile Functionality: The inverter card can be programmed and customized to meet the specific needs of various motor control applications. Easy Installation: The card is easy to install and can be integrated with other components in the Innovation Series drive, allowing for seamless system configuration and operation. Advanced Diagnostics: Includes advanced diagnostics features, providing detailed information on motor performance and status, which can be used for maintenance and troubleshooting purposes. High Compatibility: The inverter card is compatible with various types of AC motors, making it suitable for a wide range of industrial applications. Application Data The boards connect directly the IGBT gate, emitter, and collector terminals and to the control rack's BPIA Bridge Personality Interface (BPIA) board. The boards contain no fuses, testpoints, or configurable items. 

 Powerrex IGBT: CM1000HA-28H No.of board per drive: 3 (1 per phase leg) Frame: 620 IGBT per phase leg (3 phase legs per drive): 1 Single IGBT module for upper phase leg, 1 singleIGBT module for lower phase leg. LED indicators DS1 (UON - Yellow): This LED indicator, labeled DS1, is used to indicate the state of the upper power switch or upper power circuit. When the upper power switch or circuit is turned on and actively conducting current, the DS1 LED illuminates, emitting a yellow light. It signifies that the upper power section is in an active state and functioning properly. DS3 (UFF - Green): The DS3 LED indicator, labeled DS3, is used to indicate the state of the upper power switch or upper power circuit when it is turned off. When the upper power switch is in the off state or not conducting current, the DS3 LED lights up, emitting a green light. 

It provides visual confirmation that the upper power section is inactive and not actively supplying power. DS2 (LON - Yellow): The DS2 LED indicator, identified as DS2, is used to indicate the state of the lower power switch. When the lower power switch or circuit is turned on and actively conducting current, the DS2 LED illuminates, emitting a yellow light. It signifies that the lower power section is in an active state and functioning properly. DS4 (LFF - Green): The DS4 LED indicator, labeled DS4, is used to indicate the state of the lower power switch or lower power circuit when it is turned off. When the lower power switch is in the off state or not conducting current, the DS4 LED lights up, emitting a green light. It provides visual confirmation that the lower power section is inactive and not actively supplying power. Gate Driver Power Supply P15L: Represents the positive power supply voltage for the lower gate driver. It provides a +15 V direct current (dc) power to the lower gate driver circuit. This voltage level is crucial for enabling the proper operation of the lower gate driver and facilitating the control signals needed to drive the lower power devices effectively. 

N7L: Refers to the negative power supply voltage for the lower gate driver. It supplies a -7.5 V dc power to the lower gate driver circuit. This negative voltage is necessary to establish the appropriate biasing and voltage levels required for reliable and efficient gate control of the lower power devices. It ensures the proper functioning of the lower gate driver. P15U: Signifies the positive power supply voltage for the upper gate driver. It delivers a +15 V dc power to the upper gate driver circuit. Similar to the P15L, this voltage level is vital for facilitating the control signals and gate driving requirements of the upper power devices, ensuring their optimal performance and operation. N7U: Denotes the negative power supply voltage for the upper gate driver. It supplies a -7.5 V dc power to the upper gate driver circuit. 

This negative voltage plays a critical role in establishing the necessary biasing and voltage levels for effective gate control of the upper power devices. It enables reliable and efficient operation of the upper gate driver. Third-Party Connectivity GSM supports turbine control commands, data and alarms, alarm silence, logical events, and contact input sequence of events records with a resolution of 1 ms. One of three methods can be used to connect the system to the plant's DCS: Modbus link from the RS-232C port of the HMI Server to the DCS A high-speed Ethernet link at 10 Mbaud using the Modbus over TCP/IP protocol A high-speed Ethernet link at 10 Mbaud using the TCP/IP protocol and an application layer known as GEDS Standard Messages (GSM) Fault Detection A system with redundancy may be less reliable than a system without redundancy. The system must be capable of detecting and reporting faults so that they can be repaired before a forced outage occurs. Fault detection is required to ensure that a component or group of components is functioning properly. One or more of the following methods are used to detect faults. 

Process operator inspection; Equipment operator inspection. Special hardware circuits for operation monitoring Hardware and software watchdogs Logic in software Heartbeats in software There are numerous potential failure points in complex control systems. To create foolproof fault detection, this can be very expensive and time consuming. 

The failure to control a system's outputs is the most dangerous. To achieve the highest level of reliability, fault detection must be determined as close to the output as possible. The Mark VIe provides a high level of detection and fault masking by voting the outputs of all three controllers and monitoring discrepancies using triple redundant controllers and I/O modules. Output Processing The three controllers' signal outputs are divided into three categories: Outputs are driven from individual I/O networks as single ended non-redundant outputs; Outputs exist on all three I/O networks and are merged into a single signal by the output hardware. Outputs exist on all three I/O networks and are output separately to the controlled process. This procedure may include external voting hardware. The three signals feed a voting relay driver, which operates a single relay per signal for normal relay outputs. For critical protective signals, the three signals feed a voting relay driver, which operates a single relay per signal. Three independent relays are driven by the three signals, with the relay contacts connected in the standard six-contact voting configuration.IGBT AT INVERTER SNU

IC697MDL740

IC670PBI001

IC698CHS117C

DS200TCQAG1BHF

IS200AEPCH1ABC

IC697MDL250

IC697MDL250

760-P1-G1-S1-LO-A20-R

SR489-P5-LO-A20-E

IC670CHS001E

IC697MDL653

IS200VTCCH1CBB

VMIVME-4150

  • Tricon 8120E card is in stock.
  • NE870 Network Router ABB 3BSE080239R1
  • ALSTOM V4561484-0100 Amplifier Module Rev 7 Pcb Circuit Board
  • Model 10959-201 and -203 Wall-Mount Audio Messenger Interfaces
  • HIMA X-SB 01985210207 24VDC System bus module
  • HIMA X-FAN 18 03 High-efficiency cooling plate fan
  • HIMatrix F3 AIO8/4 01 HIMA Compact Controller
  • 3BHE039770R0102 PP D539 A102: AC 800PEC Contr. Device
  • ABB CMC 70, Controller, SW-Vers. 1.61/2.11
  • GE SR760-CASE 750/760Feeder Management Relay® Instruction Manual
  • ABB REG670 C30 Version 2.0 General Information
  • REF543KM127BAAA ABB FEEDER TERMINAL
  • Danaher driver SAM-DA-400/480-07N-P4N-F
  • GE FANUC/ALSTOM LC106-1- LE108 LC105 LC106 Spot model
  • ALSTOM AB121丨AY00000000266/B technical parameter
  • GE ALSTOM LE109A-1 control card data
  • GE ALSTOM IR139-1丨063022350 丨80801419 Control card. data
  • Alstom Control Set-UT150-1 Kongjiang-spot
  • ALSTOM AL132丨AL132A Control Card
  • PM1118丨ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • DEIF DLQ72-PC-PY ROLLS-ROYCE K85240 PITCH INDICATOR 10V
  • Rolls-Royce Marine R10I53S/R10I53S Panel Computer 98H0101A0000I Rev 1.9
  • ROLLS-ROYCE P001240-1 display REV 2
  • ROLLS-ROYCE RRDIO15 I/O ALARM MODULE
  • Rolls-royce UN930 Digital Display Controller 24V
  • ROLLS-ROYCE MARINE LAUER LCA 325.P2 PROFIBUS-DP NET DISPLAY PANEL UN924
  • ROLLS-ROYCE MARINE AS 5880-PC1002 STEERING GEARS-TENFJORD PCB card
  • ROLLS-ROYCE UN31 ECR panel 000127603
  • Rolls-royce ship AS UN991.1 distributing plate
  • ROLLS-ROYCE 5045 K THRUSTER CONTROLLER PANEL
  • Rolls-Royce SLIO 02 Canman controller network
  • Rolls-Royce E-1071 automatically displays 07918 B UN 921 ECR 24VDC
  • ROLLS ROYCE PCC1030C ULSTEIN panel controller card
  • ROLLS-ROYCE KAMEWA PROPELLERS control room panel basic R160637A
  • ROLLS-ROYCE UN925 Panel Controller
  • Rolls-royce Marine AS UN921 OPRETOR panel
  • Rolls-Royce Marine r10I53s/R10I53S Panel Computer 98H0101A0000I
  • ROLLS-ROYCE H1111.0104 ocean controller P/N:75669
  • Rolls-Royce H1111.0203 Marine Controller Version 2.2
  • Rolls-Royce H1111.0102 Marine Controller
  • Rolls-Royce H1127-0101 Marine Controller 00068308H6045/433
  • Rolls-Royce H1111.0103 Marine Controller 75669 Version 2.2
  • EMERSON KJ3221X1-BA2 VE4035S2B1 ATEX Instruction Sheet
  • EMERSON VE4017P0 M-series FOUNDATION™ Fieldbus I/O
  • A6740 16-Channel Output Relay Module for the AMS 6500 Machinery Health Monitor
  • EMERSON A6120 Protection Cards for AMS 6500 Classic Systems
  • A6000 series A6125 electric vibration monitor Emerson
  • EMERSON A6000 series control card A6410
  • EMERSON A6370 Overspeed Protection Monitor
  • ABB 3BHB015651P0001 DKTFM418B Power converter assembly
  • Westingouse Ovation 5X00500G01 Speed detector module
  • Emerson 5X00875G01 Analog input EMOD module
  • UNIOP ETT-VGA-0045 HMI touch unit with colour graphic display and VGA resolution. Available with high-quality TFT
  • General Electric Mark VI series IS200JPDBG1A IS200JPDBG1ABB printed circuit
  • General electric IS200EDISG1A distribution board
  • IS400TDBTH6A Mark* VIe control system Extended product life cycle description
  • DS200DCFBG1BLC General Electric Power Supply Board
  • 5485C Velocity Sensor Metrix
  • ABB 3BSE031155R1 BC810K02 CEX-bus Interconnection Unit
  • DCS602-0250-51-15 ABB DCS 600 Overload Capability
  • DCS602-0520-51/15 ABB Permanent drive
  • 853-032776-001 Lam Research Paddle Lifter
  • Modbus Plus Communication Module MVI56-MBP
  • PLC board (head) module KEBA CPU IP70
  • DS200DSFBG1A Driver/Shunt Feedback Board technical specifications
  • DS200DPCAG1ADB IOS + Power Connect Board Technical Specifications
  • DS200DPCAG1A IOS & Power Connect Card Assembly
  • Hirschmann MM20-P9P9T1T1SAHH Media Converters
  • Hirschmann MM20-P9P9P9P9SAHH In installation instructions
  • Hirschmann MM4-2TX/SFP Media Converters
  • Hirschmann MM4-4TXSFP-datasheet
  • Hirschmann MM3-1FXL23TX1_techdata MM3-1FXL2/3TX1
  • Hirschmann MM3-4FXS2 PowerMICE series industrial switch products
  • Hirschmann MM3-2FXS2/2TX1 Media Converters
  • MM3-1FXM2/3TX1 Hirschmann Ethernet & Communication Modules
  • Hirschmann MM3-4TX5 Media module
  • Hirschman MM2-2FXM3/2TX1 Media Module article will analyze the technical features of this product in detail
  • Hirschmann MM2-4TX1 Performance parameters of compact and modular managed Ethernet switch
  • MS4128-L3E ATEX Power mouse, modular, managed industrial Ethernet switch
  • Hirschmann MS4128-L2P ATEX 943009101, Power MICE, modular, managed Industrial
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SAHH
  • Hirschmann MM20-T1T1T1T1SZHH Managed Ethernet switch
  • Hirschmann MM20-M4T1T1T1SAHH Media converter
  • Detailed explanation of Hirschmann GMM20-mmmmmev9HHS9 xx.x.xxx Ethernet module
  • Hirschmann MM20-M2M2M2T1SAHH Management Ethernet Switch Function and Configuration Guide
  • Product introduction and technical specifications of Hirschmann MM20-M2M2M2M2EAHH media converter
  • Hirschmann MM20-M4M49999TAHH Media converter
  • Hirschmann MM20-Z6Z6Z6Z6TAHH Media converter
  • Media converter MM20-M2M29999EAHH Data
  • Media converter MM20-G2T1T1T1SAHH Hirschmann
  • Hirschmann Media converter MM20-M2T1T1T1TAHH
  • Hirschmann Ethernet module GMM GMM20-VVVVVVVVSY9HHS999.9.XX
  • Managed Ethernet Switch MM20-M4M4M4M4TAHH
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SSHH
  • Hirschmann Managed Ethernet Switch MM20-Z6Z6Z6Z6SSHH
  • Media converter MM20-T1T1T1T1TAHH Hirschmann
  • Hirschmann Media converter MM20-M4M4T1T1EAHH
  • MM20-M4M4M4M4EAHH Hirschmann Media converter
  • Hirschmann Media converter MM20-M2M2M2M2SAHH
  • Hirschmann Managed Ethernet Switch MM20-S2S2T1T1SYHH
  • ABB SDCS-POW-4 POWER SUPPLY
  • AMAT 0090-35032 ARSINE DETECTOR 0-1000PPB
  • SMC XLFD-100D-X1236 high vacuum valve 0.4 ~ 0.7MPa 5 ~ 60°C
  • 50DW412745 Control Module United Technologies Carrier
  • Carrier 50DW404638 Control module CEAS430189-02
  • TRICONEX 2481 I/O Module
  • WARNER ELECTRIC HMCS2000-PRG Programmer
  • WARNERELECTRIC MCS2000-ECA Digital control
  • Related Manuals for WAGO WAGO-I/O-IPC 758-870 and 58-873Series
  • IOC4T-RLC16 Vibro-Meter company VM600 system and sensor technical data
  • MEGGITT VIBRO-METER 200-510-076-114 VM600 MPC4 Descriptive data
  • IPC704 Signal conditioner MEGGITT VIBRO-METER IPC704 244-704-000-032 AMP
  • GSI127 galvanic separation unit MEGGITT VIBRO-METER GSI 127 244-127-000-017 A1-B02 MODULE
  • ABB Relion® 650series REC650/REL650/RET650/REB 650/REQ 650
  • Rexroth Sercos III analog, axis module R-ILB S3 AI12 AO4 SSI-IN4
  • DS200DMCBG1ABB DOS DUP Processor Board
  • DS200DMCAG1AAA Gen/Log/Key Interface Board
  • DS200DKLBG1ABB Power Connect Board
  • General Electric DS200DENCF1BDE01 EEPROM with Firmware
  • DS200DDTBG2ABB LCI Auxiliary I/O Terminal Board
  • DS200DCVAG1A DC Power and Instrumentation Board
  • DS200DCPAG1 DC Power Board GE General Electric
  • DS200DCFBG1B DC Feedback Power Supply Board
  • DS200DCFBG1AAA DC Power Feedback Board
  • DS200DACAG1 TC/DC AC/DC Convertor Board
  • DS200CVMAG3AEB Cap/Fuse Voltage Monitor Board
  • DS200CVMAG1AEB Capacitor Voltage Monitor Assembly
  • DS200CTBAG1A Analog Termination Module