Description
IS200EDEXG1B

Part Number IS200EDEXG1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series EX 2100e Function Module Availability In StockIS200EDEXG1B is an exciter De-Excitation Control Board designed and developed by GE. 

The EDEX is the de-excitation module's main board. When an emergency shutdown occurs and the field breaker or contactors open, this module removes stored energy from the generator field. To ensure operation in the event of a power outage, EDEX includes SCR firing, conduction sense feedback, and voltage retention. On the EXTB board, EMIO initiates de-excitation. 

The EXTB board activates the 41dc contactor (MDA/MDB) or breaker, then transfers de-excitation signals from the auxiliary contacts to the EDEX's SCR firing circuits. EDEX boards are classified into two types. Group 1 is for SCR de-excitation, while Group 2 is for diode de-excitation. IS200EDEXG1B Functional Description Two firing commands are received through the EXTB and activate the firing circuit with redundant control. When the circuit is activated, it generates a high frequency square wave that is connected to the SCR gate and causes conduction. If this circuit fails or is delayed, the gate is activated by a self-firing circuit. 

This circuit consists of a break-over diode network connected to the SCR gate and controlled by the SCR anode voltage. Voltage Hold Up Circuit In the event of a total power failure, EDEX retains voltage on the positive and negative 24 V dc lines so that it can fire the SCR. 

The voltage hold up circuitry also provides voltage for wetting the external de- excitation contacts. 

This ensures that the firing command is available for de-excitation in the event of a power outage. Conduction Sensors EDEX uses Hall Effect sensors to detect current in the field circuit. A mechanical ring couples magnetic flux to the sensors on the board's top edge. Separate circuits detect bi-polar current flow in sensor circuits 1 and 2. The current sense signals M1 and M2 are sent to EXTB and then to control. 

The mechanical ring is configured to detect unidirectional current flow in diode de-excitation applications. The status of both current sense circuits is indicated by two red LEDs. When current flow is detected, the indicators illuminate. SCR Firing Voltage The voltage and type of SCR used determine the SCR anode firing voltage. Wire jumpers are used to set the Break Over Diodes (BODs) and current limiting resistors. M1, M2, and the Break Over Diodes are wired together and connected to the gate of the SCR via the DEPL connector. The EDEX will be destroyed if the break-over voltage of a break-over diode is exceeded and the BOD is not connected to the gate of the SCR. Check that the firing control circuit will fire the SCR before attempting to fire it by exceeding the break-over voltage of the BOD. IS200EDEXG1B Replacement Procedures Verify that the panel in which the board is located has been de-energized. Open the auxiliary cabinet door and check any electrical circuits for power before touching them. 

Disconnect all cables from the EDEX board with care as follows: Ensure that all cables are labeled with the correct connector name (as indicated on the board) to facilitate reconnection. Remove all cables from the board and remove the stab on wire jumper from connector E1A, leaving the other wire jumpers in place. Remove the conduction ring (flux concentrator) that sits on top of the Hall Effect sensors. Remove the EDEX board by opening the PEM Snap Top fasteners that hold it to the intermediate mounting panel. Arrange the wire jumpers on the replacement EDEX board in the same order as on the old board, and double-check that jumpers JP1 and JP6 are in the same position. 

Place the replacement EDEX board in the same location on the mounting panel as the one that was removed, and secure it with the Snap Top fasteners. Install a new conduction ring. Reconnect all cables to the EDEX board as labeled, as well as the wire jumper to E1A, and double-check that cables are properly seated on both ends. Close the door to the auxiliary cabinetEXCITER DE-EXCITATION

Related models

0880001-01

104X905BA603

12A0-0103-A3

12HFA51A42H

12HGA11J52

269 PLUS-D/O-100P-125V

369-A200

369B1860G0026

369B1860G0030

  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives