Description
IS200EPDMG1B

Part Number IS200EPDMG1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series EX 2100e Function Module Availability In StockIS200EPDMG1B is an Exciter Power Distribution Module developed by GE under EX2100. 

It is employed in the EX2100 Excitation Control to supply power to the exciter's control, I/O, and protection boards. It is located on the side of the Exciter Power Backplane (EPBP) and is powered by one or two 120 V ac inputs in addition to the station battery's 125 V dc output. A board-mounted terminal block (TB1) serves as the entry point for all power supply inputs and filters them. In an external AC to DC converter, each ac supply is rectified to 125 V dc (DACA). 

The resulting two or three dc voltages are connected together using external diodes to provide the P125V and R125V dc source power supplies. These voltages are nominally +62.5 V and -62.5 V to the ground and are center grounded. IS200EPDMG1B Features Through four of the holes on the board for mounting, the module is safety grounded and chassis ground. 

The external DACA#1 and DACA2 are connected to the terminal block's AC1 and AC2 by two 12-plug connections (JDACA1 and JDACA2), and the DACA outputs are then connected to the 125 V dc lines (P125 and R125). With the exception of the EXTB board, each individual power supply output to an exciter board is fused, equipped with an on/off toggle switch, and has a green LED indicator to indicate power availability. 

Three Exciter Gate Pulse Amplifier Boards (EGPA), Exciter Terminal Board (EXTB), and three Exciter Power Supply Modules (EPSM) feeding three controllers are all capable of receiving power from the outputs. Each output has its own connector, which is attached to the EPBP for distribution. 

 Application Data A 24-point terminal block, ten plug connectors, seven switches, fourteen fuses, four grounded mounting holes, eight LED indicators, and a single adjustable jumper are all parts of the EPDM module. Each connector has a 600 V ac or dc rating. All switches are rated at 125 V dc, 6 A, but the terminal board is rated at 300 V (10 A per pin). On systems with external reference, the adjustable jumper (BJS) isolates the ground reference. Handling Precautions Use static-sensitive handling techniques on all boards to avoid component damage due to static electricity. 

When handling boards or components, use a wrist-grounding strap, but only after the boards or components have been taken out of potentially electrified machinery and are at a normally grounded workstation. 

 IS200EPDMG1B Replacement Procedures Check if the exciter has been de-energized. Check that the power is off before touching any electrical circuits by opening the control cabinet door and using high voltage testing equipment. Take note of every switch's location on the board, then turn them all off. Carefully detach every cable connector from the board and remove it from the EPDM module. To make reconnection easier, ensure all wires are identified with the correct connector name (as indicated on the board).EXCITER PWR DIST MODULE 

Related models

0880001-01

104X905BA603

12A0-0103-A3

12HFA51A42H

12HGA11J52

269 PLUS-D/O-100P-125V

369-A200

369B1860G0026

369B1860G0030

369-C100

369-C101

369-HI-0-0-0-0

369-HI-0-M-F-E-0

369-HI-R-M-0-0-0-E

369-HI-R-M-0-E-0

369-HI-R-M-0-P-0-E



  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives