KONG -Y
NameDescriptionContent
Location:
product
IS200GDDDG1A Gate driver and dynamic discharge plate
❤ Add to collection

IS200GDDDG1A Gate driver and dynamic discharge plate

IS200GDDDG1A
U.S.$26150.00
U.S.$19825.00
U.S.$18833.75
U.S.$18437.25
Weight:3.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200GDDDG1A

Part Number IS200GDDDG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series EX 2000 Function Module Availability In StockIS200GDDDG1A is a Gate Driver and Dynamic Discharge Board manufactured and designed by General Electric. 

The interface isolation between the IGBTs and the main processor firing circuits is provided by the Gate Driver and Dynamic Discharge board (GDDD). The GDDD board, as well as the gating circuits for the A and B leg active IGBTs, use dynamic discharge circuit control. This board also provides the regulator's instrumentation. The GDDD board processes the output dc voltage, dc link voltage, shunt current mV input, and heat sink thermistor input before sending them to the LDCC processors for use by the regulators. 

 Jumpers JP1 - JP3 jumpers on the GDDD board configure the following items: The JP1 jumper configures the dc output voltage input level to the GDDD board inputs APL-6 and BPL-5. It must match the value in EE.612 (VDCMAX). The JP2 jumper configures the dc link voltage input level to the GDDD board inputs CPL-12 and CPL-2. It must be consistent with the value in EE. 612 (VDCMAX) (VDCMAX). The JP3 jumper configures the dc dynamic discharge reference to the GDDD board's inputs CPL-12 and CPLCOM. It should correspond to the level in EE.612(VDCMAX), so that when EE.612 = 604, JP.3 = 500, and when EE.612 = 360, JP.3 = 300. IS200GDDDG1A LEDs The LED "Bridge OK," DS100 on the GDDD board indicates that no IGBT leg faults or overcurrents have been detected. The LED "IMOK", DS101 on the GDDD board indicates that there are no bridge faults, the unit is not reset, the power supply voltages are correct, and no dynamic discharge faults have been detected. The LED DS102 "DD AUX POWER AVAILABLE" indicates that auxiliary power for the dynamic discharge circuit is available from the dc link source via the RDS connection. Test Points Analog TP1 0-5 V proportional to PWM output voltage of a bridge TP2 Analog 0-5 V proportional to the output current of the PWM bridge TP3 Analog 0-5 V proportional to the dc link voltage of the PWM. TP4 DCOM GDDD board signal common reference Dynamic Discharge command value TP5 Dynamic Discharge feedback value TP6 TP7 When combined with TP8, this test point provides the PWM bridge's dc output voltage. 

TP8 When combined with TP7, this test point provides the PWM bridge's dc output voltage. Procedure for IS200GDDDG1A board replacement Remove all input power. To reveal the PSCD board, open the upper board rack door. Behind this board is the GDDD board. Remove the latch and lower the board rack. Disconnect all cables from the GDDD board with care, as shown below: Carefully pull the tab on ribbon connectors with pull tabs. One edge of the connector is secured to the board plug for plug connectors. Remove the securing clip and gently pull on the connector's sides until it comes free. To remove the connector from a stab connector, use needle-nose pliers. Remove the GDDD board from the rack by releasing the securing clips that hold it in place. Set the jumpers on the new board to match the jumpers on the old board. Install the new board and reconnect all cables, making sure that each connector is seated properly on both ends. Features The dynamic discharge circuitry on the GDDD board regulates the C leg of the 3-phase IGBT pack. In the case that control power is lost, a backup power source is supplied to the GDDD board using the RDS resistor for the discharge circuit. The control level of the dc link by the dynamic discharge circuit is set by jumper settings on the GDDD board. The dc link capacitors are connected to the IGBT bridge via the IAXS board, along with dynamic discharge control and gate control from the GDDD board. The IAXS board serves as a connection point for the control circuitry's sensing feedback and dc output voltage.EX2000 PWM GATE DR

Related models

DS200SHVMG1AFE

IC660ELB912

IS230TVBAH2A

IS215VCMIH2BB IS200VCMIH2BCC

IS210MACCH1AGG

SR489-P5-LO-A20-E

MVR1600-4601

D20 EME 2400-21004

IC697MDL350

8101-HI-TX-02

IC698PSA100

IC698RMX016-ED

IC660BBD025

531X303MCPARG1

DS200FSAAG1ABA

  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software
  • Bently 2300/20 and 2300/25 2300 Vibration Monitors
  • ABB NGC8206 Natural Gas Chromatograph Dual Unit
  • MOTOROLA MVME2400 TM VME Processor Modules
  • 5320 Series Foxboro DCS Control Network Ethernet Equipment
  • ExtremeSwitching™ 5420 Series
  • WOODWARD EGCP-3 Engine Generator Control Package LS (Load Sharing)
  • 5520 Series Universal Edge/Aggregation-Switch Platform
  • X440-G2 Series
  • EMERSON FloBoss™ S600 Flow Manager Specification Sheet
  • KONGSBERG RAIV400 Remote Analogue Input, Voltage
  • RMP420-Remote Multipurpose Input/Output Kongsberg
  • 610 serie ABB Feeder Protection REF610 Product Guide
  • Triconex 3351S2 Controller Features
  • HBRF Megamax – Emax2 Air Circuit Breaker ABB
  • ABB MEASUREMENT & ANALYTICS | DATA SHEET LS4000 Diode laser analyzer
  • Pressductor Pillowblock Load Cells Vertical Measuring PFCL 201 User manual
  • PARKER BFR5K Series
  • AC 900F controller ABB
  • Uniop ePAD05 and ePAD06 Technical description
  • Hitachi ABB Communication Unit 560CMR02
  • MOTOROLA MVME5500 Series VME Single-Board Computer
  • ABB Symphony Plus SD Series HPC800 controller
  • ABB AC800M Controller Hardware System
  • ABB AC800M PROFIBUS DP Installation System
  • ABB Freelance 800F AC800F Control systems
  • ABB Compact control system replaces PLC AC700F
  • abb Triguard SC300E 3BNP004720R101 TMR Safety Products
  • ABB Distributed busbar protection REB500
  • ABB Advant Controller 400 series