KONG -Y
NameDescriptionContent
Location:
product
IS200ISBBG1A Manufacturer General Electric Country
❤ Add to collection

IS200ISBBG1A Manufacturer General Electric Country

IS200ISBBG1A
U.S.$23380.00
U.S.$9085.00
U.S.$8630.75
U.S.$8449.05
Weight:3.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200ISBBG1A

Part Number IS200ISBBG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200ISBBG1A is an Insync bus bypass card developed by GE. 

It is a part of EX2100 excitation system. The module incorporates a JP1 Interlock Bypass feature, which provides enhanced flexibility and control over the interlock functionality. The interlock bypass allows users to temporarily override the interlock system, enabling specific operations or functions to proceed even when certain interlock conditions are present. IS200ISBBG1A FEATURES Compact Size and DIN Rail Mounting: Designed to be compact, allowing for easy installation and integration into control systems. It is typically mounted on DIN rails, which are standard mounting rails used in industrial applications. 

The module's size and form factor make it suitable for space-constrained environments, providing flexibility in installation. Secure Mounting: Securely mounted on the DIN rail using screws. The DIN rail has four factory-drilled holes that align with corresponding holes on the module. The conductive material surrounding these holes ensures proper grounding and electrical connectivity. The holes are conveniently labeled as E1, E2, E3, and E4, aiding in the identification and connection of external components or other boards. 

Connector Options: Equipped with four connectors to facilitate connections with off-board components or other modules. These connectors include three plug connectors labeled as P1, P2, and P3, and a terminal strip labeled as P4. The specific functions of these connectors are identified as follows: P1 - Full Duplex, P2 - XMIT Data Out, P3 - RCV Data In, and P4 - 24 VDC Input. The connectors provide convenient interfaces for data exchange and power supply connections. Terminal Strip and Screw Connections: In addition to the plug connectors, the module features a terminal strip (P4) with two screw connections. This terminal strip offers a flexible and reliable means of connecting external wires or cables. It allows for secure and easily accessible connections, enhancing the overall functionality and versatility of the module. 

Jumper Position Indication: It includes a jumper whose position and corresponding outcome are clearly indicated on the board's surface. This visual indication assists in identifying the current configuration or setting of the jumper. The jumper's position may have an impact on the module's functionality or behavior, and the clear labeling ensures accurate setup and operation. LED Indicators: Features two LEDs, yellow and green, which serve as status indicators. 

The yellow LED represents XMIT data, providing visual feedback on the transmission of data. The green LED indicates the active state of the interlock, signaling whether the interlock system is engaged or not. These LED indicators provide quick and intuitive visual cues for monitoring the module's status. Integrated Voltage Comparator: The module incorporates an integrated circuit that includes a voltage comparator with a response time of 200ns. This voltage comparator plays a critical role in comparing voltages and generating output signals based on predefined thresholds. Its fast response time ensures efficient and accurate voltage comparisons, contributing to the overall performance and reliability of the module. CONTROL POWER SUPPLIES The exciter shares the HMI on turbine generator sets that include Mark VI turbine controls. 

The HMI is Windows NT-based, with CIMPLICITY operator display software and data highway communication drivers. From the HMI, the operator can initiate commands and view real-time data and alarms on the CIMPLICITY graphic displays. An HMI can be set up as a server or a viewer, and it can include tools and utility programs. The exciter is linked to the HMI or HMI/Data Server via the Unit Data Highway (UDH). The network is 10BaseT Ethernet, and uses separately powered network switches. Fiber-optic cables can be used for longer runs. DIN-RAIL-MOUNTED This model is exclusively suitable for DIN-rail-mounted setups. Power supply input for the model operates at 24 VDC. Functionality as an InSync Bus Bypass Card. Within the Mark VI system, it serves as an InSync Bus Bypass Card. The top edge of the board is marked with the board number and code 6BA01. The code 6DA01 is positioned along the bottom edge of the board. BOARD DESIGN AND MOUNTING The board features multiple factory-drilled locations, with four holes (E1, E2, E3, E4) surrounded by conductive material for DIN rail mounting. Two side-by-side relays are located left of the center of the board. 

The presence of rectifier coils, LED indicators (green and yellow), and a jumper switch are notable. COMPONENTS AND CONNECTIVITY A voltage comparator integrated circuit is present on the board. Connectors include three plugs marked P1 through P3, labeled Full Duplex, Xmit Data Out, and Rcv Data In. A short terminal strip with screw connections is labeled 24 VDC Input. COMPARISON BETWEEN ISBB GROUPS Due to the lack of documentation from General Electric, any major differences between ISBB groups are unknown. Visual inspection reveals no apparent differences between the two models. Features such as relays, potentiometers, and LED indicators are common to both models.

LED INDICATORS AND DATA STATUS The model incorporates two LEDs: Interlock Active (green) and XMIT Data (yellow). These LEDs signify data and activity status. Whether the LEDs remain solid or flash to indicate faults is uncertain. DATA OUTPUT INDICATION The XMIT Data LED assists in indicating data transmission or reception. A labeled plug for XMIT Data out facilitates data outputs. CONNECTORS P1-Full Duplex: Plug connector for full-duplex communication. P2-XMIT Data Out: Plug connector for transmitting data. P3-RCV Data In: Plug connector for receiving data. P4-24 VDC Input: Terminal strip with two screw connections for a 24 VDC input. MOUNTING Typically designed to be mounted on DIN rails. The board can be mounted using screws to four of its six factory-made drill holes. The holes used for mounting are labeled E1, E2, E3, and E4 and are ringed with a conductive material.INSYNC BUS BYPASS


  • Tricon 8120E card is in stock.
  • NE870 Network Router ABB 3BSE080239R1
  • ALSTOM V4561484-0100 Amplifier Module Rev 7 Pcb Circuit Board
  • Model 10959-201 and -203 Wall-Mount Audio Messenger Interfaces
  • HIMA X-SB 01985210207 24VDC System bus module
  • HIMA X-FAN 18 03 High-efficiency cooling plate fan
  • HIMatrix F3 AIO8/4 01 HIMA Compact Controller
  • 3BHE039770R0102 PP D539 A102: AC 800PEC Contr. Device
  • ABB CMC 70, Controller, SW-Vers. 1.61/2.11
  • GE SR760-CASE 750/760Feeder Management Relay® Instruction Manual
  • ABB REG670 C30 Version 2.0 General Information
  • REF543KM127BAAA ABB FEEDER TERMINAL
  • Danaher driver SAM-DA-400/480-07N-P4N-F
  • GE FANUC/ALSTOM LC106-1- LE108 LC105 LC106 Spot model
  • ALSTOM AB121丨AY00000000266/B technical parameter
  • GE ALSTOM LE109A-1 control card data
  • GE ALSTOM IR139-1丨063022350 丨80801419 Control card. data
  • Alstom Control Set-UT150-1 Kongjiang-spot
  • ALSTOM AL132丨AL132A Control Card
  • PM1118丨ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • DEIF DLQ72-PC-PY ROLLS-ROYCE K85240 PITCH INDICATOR 10V
  • Rolls-Royce Marine R10I53S/R10I53S Panel Computer 98H0101A0000I Rev 1.9
  • ROLLS-ROYCE P001240-1 display REV 2
  • ROLLS-ROYCE RRDIO15 I/O ALARM MODULE
  • Rolls-royce UN930 Digital Display Controller 24V
  • ROLLS-ROYCE MARINE LAUER LCA 325.P2 PROFIBUS-DP NET DISPLAY PANEL UN924
  • ROLLS-ROYCE MARINE AS 5880-PC1002 STEERING GEARS-TENFJORD PCB card
  • ROLLS-ROYCE UN31 ECR panel 000127603
  • Rolls-royce ship AS UN991.1 distributing plate
  • ROLLS-ROYCE 5045 K THRUSTER CONTROLLER PANEL
  • Rolls-Royce SLIO 02 Canman controller network
  • Rolls-Royce E-1071 automatically displays 07918 B UN 921 ECR 24VDC
  • ROLLS ROYCE PCC1030C ULSTEIN panel controller card
  • ROLLS-ROYCE KAMEWA PROPELLERS control room panel basic R160637A
  • ROLLS-ROYCE UN925 Panel Controller
  • Rolls-royce Marine AS UN921 OPRETOR panel
  • Rolls-Royce Marine r10I53s/R10I53S Panel Computer 98H0101A0000I
  • ROLLS-ROYCE H1111.0104 ocean controller P/N:75669
  • Rolls-Royce H1111.0203 Marine Controller Version 2.2
  • Rolls-Royce H1111.0102 Marine Controller
  • Rolls-Royce H1127-0101 Marine Controller 00068308H6045/433
  • Rolls-Royce H1111.0103 Marine Controller 75669 Version 2.2
  • EMERSON KJ3221X1-BA2 VE4035S2B1 ATEX Instruction Sheet
  • EMERSON VE4017P0 M-series FOUNDATION™ Fieldbus I/O
  • A6740 16-Channel Output Relay Module for the AMS 6500 Machinery Health Monitor
  • EMERSON A6120 Protection Cards for AMS 6500 Classic Systems
  • A6000 series A6125 electric vibration monitor Emerson
  • EMERSON A6000 series control card A6410
  • EMERSON A6370 Overspeed Protection Monitor
  • ABB 3BHB015651P0001 DKTFM418B Power converter assembly
  • Westingouse Ovation 5X00500G01 Speed detector module
  • Emerson 5X00875G01 Analog input EMOD module
  • UNIOP ETT-VGA-0045 HMI touch unit with colour graphic display and VGA resolution. Available with high-quality TFT
  • General Electric Mark VI series IS200JPDBG1A IS200JPDBG1ABB printed circuit
  • General electric IS200EDISG1A distribution board
  • IS400TDBTH6A Mark* VIe control system Extended product life cycle description
  • DS200DCFBG1BLC General Electric Power Supply Board
  • 5485C Velocity Sensor Metrix
  • ABB 3BSE031155R1 BC810K02 CEX-bus Interconnection Unit
  • DCS602-0250-51-15 ABB DCS 600 Overload Capability
  • DCS602-0520-51/15 ABB Permanent drive
  • 853-032776-001 Lam Research Paddle Lifter
  • Modbus Plus Communication Module MVI56-MBP
  • PLC board (head) module KEBA CPU IP70
  • DS200DSFBG1A Driver/Shunt Feedback Board technical specifications
  • DS200DPCAG1ADB IOS + Power Connect Board Technical Specifications
  • DS200DPCAG1A IOS & Power Connect Card Assembly
  • Hirschmann MM20-P9P9T1T1SAHH Media Converters
  • Hirschmann MM20-P9P9P9P9SAHH In installation instructions
  • Hirschmann MM4-2TX/SFP Media Converters
  • Hirschmann MM4-4TXSFP-datasheet
  • Hirschmann MM3-1FXL23TX1_techdata MM3-1FXL2/3TX1
  • Hirschmann MM3-4FXS2 PowerMICE series industrial switch products
  • Hirschmann MM3-2FXS2/2TX1 Media Converters
  • MM3-1FXM2/3TX1 Hirschmann Ethernet & Communication Modules
  • Hirschmann MM3-4TX5 Media module
  • Hirschman MM2-2FXM3/2TX1 Media Module article will analyze the technical features of this product in detail
  • Hirschmann MM2-4TX1 Performance parameters of compact and modular managed Ethernet switch
  • MS4128-L3E ATEX Power mouse, modular, managed industrial Ethernet switch
  • Hirschmann MS4128-L2P ATEX 943009101, Power MICE, modular, managed Industrial
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SAHH
  • Hirschmann MM20-T1T1T1T1SZHH Managed Ethernet switch
  • Hirschmann MM20-M4T1T1T1SAHH Media converter
  • Detailed explanation of Hirschmann GMM20-mmmmmev9HHS9 xx.x.xxx Ethernet module
  • Hirschmann MM20-M2M2M2T1SAHH Management Ethernet Switch Function and Configuration Guide
  • Product introduction and technical specifications of Hirschmann MM20-M2M2M2M2EAHH media converter
  • Hirschmann MM20-M4M49999TAHH Media converter
  • Hirschmann MM20-Z6Z6Z6Z6TAHH Media converter
  • Media converter MM20-M2M29999EAHH Data
  • Media converter MM20-G2T1T1T1SAHH Hirschmann
  • Hirschmann Media converter MM20-M2T1T1T1TAHH
  • Hirschmann Ethernet module GMM GMM20-VVVVVVVVSY9HHS999.9.XX
  • Managed Ethernet Switch MM20-M4M4M4M4TAHH
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SSHH
  • Hirschmann Managed Ethernet Switch MM20-Z6Z6Z6Z6SSHH
  • Media converter MM20-T1T1T1T1TAHH Hirschmann
  • Hirschmann Media converter MM20-M4M4T1T1EAHH
  • MM20-M4M4M4M4EAHH Hirschmann Media converter
  • Hirschmann Media converter MM20-M2M2M2M2SAHH
  • Hirschmann Managed Ethernet Switch MM20-S2S2T1T1SYHH
  • ABB SDCS-POW-4 POWER SUPPLY
  • AMAT 0090-35032 ARSINE DETECTOR 0-1000PPB
  • SMC XLFD-100D-X1236 high vacuum valve 0.4 ~ 0.7MPa 5 ~ 60°C
  • 50DW412745 Control Module United Technologies Carrier
  • Carrier 50DW404638 Control module CEAS430189-02
  • TRICONEX 2481 I/O Module
  • WARNER ELECTRIC HMCS2000-PRG Programmer
  • WARNERELECTRIC MCS2000-ECA Digital control
  • Related Manuals for WAGO WAGO-I/O-IPC 758-870 and 58-873Series
  • IOC4T-RLC16 Vibro-Meter company VM600 system and sensor technical data
  • MEGGITT VIBRO-METER 200-510-076-114 VM600 MPC4 Descriptive data
  • IPC704 Signal conditioner MEGGITT VIBRO-METER IPC704 244-704-000-032 AMP
  • GSI127 galvanic separation unit MEGGITT VIBRO-METER GSI 127 244-127-000-017 A1-B02 MODULE
  • ABB Relion® 650series REC650/REL650/RET650/REB 650/REQ 650
  • Rexroth Sercos III analog, axis module R-ILB S3 AI12 AO4 SSI-IN4
  • DS200DMCBG1ABB DOS DUP Processor Board
  • DS200DMCAG1AAA Gen/Log/Key Interface Board
  • DS200DKLBG1ABB Power Connect Board
  • General Electric DS200DENCF1BDE01 EEPROM with Firmware
  • DS200DDTBG2ABB LCI Auxiliary I/O Terminal Board
  • DS200DCVAG1A DC Power and Instrumentation Board
  • DS200DCPAG1 DC Power Board GE General Electric
  • DS200DCFBG1B DC Feedback Power Supply Board
  • DS200DCFBG1AAA DC Power Feedback Board
  • DS200DACAG1 TC/DC AC/DC Convertor Board
  • DS200CVMAG3AEB Cap/Fuse Voltage Monitor Board
  • DS200CVMAG1AEB Capacitor Voltage Monitor Assembly
  • DS200CTBAG1A Analog Termination Module