KONG -Y
NameDescriptionContent
Location:
product
IS200JPDGG1A GE Manufacturing Policy Series Mark VI/VIe Function Module
❤ Add to collection

IS200JPDGG1A GE Manufacturing Policy Series Mark VI/VIe Function Module

IS200JPDGG1A
U.S.$9887.00
U.S.$4745.00
U.S.$4507.75
U.S.$4412.85
Weight:7.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200JPDGG1A

Part Number IS200JPDGG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200JPDGG1A is a power distribution module developed by GE. 

It is a part of Mark VIe control system. The Power Distribution board plays a critical role in the control system by efficiently distributing power to various components. It manages both control power and wetting power, along with providing sensing circuitry for ac distribution. 

The board receives 28 V dc input power from external ac/dc or dc/dc converters for control power distribution. It acts as a central hub, distributing power to the control system while ensuring fuse protection for all 28 V dc outputs. PHYSICAL ARRANGEMENT Typically positioned within the cabinet in a manner that allows convenient access for maintenance and monitoring. Connector P2, located on the JPDG, serves as the interface for receiving feedback signals from other power distribution boards within the system. These signals are then transmitted to the PPDA for analysis and monitoring purposes. When installed, it is mounted vertically within the cabinet, ensuring efficient utilization of space while maintaining accessibility. Adjacent to the module, the PPDA I/O pack is connected, facilitating seamless communication and data exchange between the two components. One notable advantage of this arrangement is the clear visibility of all indicator lights present on the PPDA I/O pack. 

These lights provide essential information regarding the status and performance of the power distribution system, allowing operators to quickly identify any issues or anomalies for prompt resolution. GROUND FAULT DETECTION The board is equipped with features to facilitate ground fault detection within the power distribution system. It utilizes a wetting voltage DC bus configuration that maintains ground potential at the center through the use of a high-resistance connection. This setup enables the detection of ground faults by monitoring the voltage levels of both the positive and negative buses concerning ground. To achieve thism, it incorporates separate voltage feedback sensing mechanisms for the positive and negative power lines concerning ground. Feedback signals from these sensing circuits are then relayed to the control system, enabling the detection and notification of ground faults. The sensitivity of ground fault detection and the magnitude of ground fault currents are determined by the resistance used to center the DC bus on ground. Within the JPDG, centering resistors are integrated and can be selected via jumper JP1. 

The presence or absence of centering resistance elsewhere in the system influences the configuration of this jumper. Responsible for providing the centering function, jumper JP1 should be closed to activate the centering resistors within the board. However, if centering resistance is implemented elsewhere in the system, JP1 should remain open. In scenarios where both the JPDG and a JPDE are employed for distributing wetting power, only one of the two boards should have its JP1 jumper closed to avoid redundancy. INSTALLATION Mounting Procedure: The board is vertically base-mounted onto a metal bracket within the control cabinet used by the Power Distribution Module (PDM). It is securely attached with four screws, utilizing mounting holes located at the top and bottom of the module base. While the location within the cabinet is not critical, distribution boards are typically mounted low to facilitate grounding. 

CONNECTION POINTS AND POWER INPUTS: Diagnostic Connector (P2): A 50-pin diagnostic connector, P2, is mounted on the bottom of the board. Power Inputs: Control Power Input (28 V DC): Either one or two 28 V dc control power input connections are made through connectors JR and JS. It features a common 28 V dc bus for efficient power distribution. Wetting Power Input (24/48 V DC): One or two 24 V dc wetting power input connections, or alternatively one or two 48 V dc input connections, are made through connectors JPS1 and JPS2. Includes a com mon 24/48 V dc wetting voltage bus. 

Integration with PPDA I/O Pack: The PPDA I/O pack is plugged into connector JA1 on the board. It is securely fastened to the base using an angle bracket and held in place with nuts threaded onto studs that are permanently attached to the base for this purpose. Diagnostic Feedback Routing: Diagnostic feedback inputs from other distribution boards are routed via a 50-pin ribbon cable attached to connector P2. This facilitates comprehensive monitoring and diagnostic capabilities within the control system.TERMINAL BOARD



  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives