KONG -Y
NameDescriptionContent
Location:
product
IS200TBAIH1C Analog input terminal board
❤ Add to collection

IS200TBAIH1C Analog input terminal board

IS200TBAIH1C
U.S.$5920.00
U.S.$13745.00
U.S.$13057.75
U.S.$12782.85
Weight:13.800KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200TBAIH1C

IS200TBAIH1C Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TBAIH1C is an Analog Input Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in gas turbine control systems. Two outputs and 10 analog inputs are supported by the Analog Input terminal board. Two-wire, three-wire, four-wire, or transmitters that are powered externally can all be plugged into one of the ten analog inputs. A current of 0-20 mA or 0-200 mA can be configured for the analog outputs. Surge and high frequency noise are protected from by noise suppression circuitry in the inputs and outputs. For connecting to the I/O processors, the TBAI has three DC-37 pin connectors available. It is possible to connect using TMR with all three connectors or simplex on one connector (JR1). Both direct connections to the electronics and cable connections are possible. To the three connectors for the R, S, and T controls in TMR applications, the input signals are fanning outward. Utilizing a measuring shunt on the TBAI, the total current of the three output drivers that are connected is combined to run TMR outputs. Following that, the electronics are given the total current signal by the TBAI so they can regulate it to the specified setpoint. IS200TBAIH1C Installation The two I/O terminal blocks located on the terminal board are directly linked to the 10 inputs and the two outputs. Each block is secured with two screws and contains 24 terminals that can accommodate wires up to #12 AWG. Next to each terminal block is a shield terminal attachment point. The following categories of analog inputs and outputs can be supported: A two-wire transmitter with an analog input Three-wire transmitter with analog input A four-wire transmitter with an analog input A transmitter with an analog input and external power Analog input, 5 and 10 volts direct current 0-20 mA analog output 0-200 mA analog output Operation All of the transducers have access to a 24 V dc power source on the terminal board. By employing jumpers, one can select between current and voltage inputs. One of the two analog output circuits can be configured through a jumper for 4-20 mA or 0-200 mA, while the other can be adjusted for either. TMR applications can both use the same terminal board. Transmitters/transducers can be individually powered or can be powered by the 24 V dc source in the control system. Jumpers and JO on the terminal board configure the input and output types of voltage and current, respectively. Diagnostics track each output, and if a defect cannot be fixed by a CPU command, a suicide relay in the I/O controller disconnects the relevant output. IS200TBAIH1C Diagnostics The output current is indicated by the board using the voltage drop across a series resistor. If either of the two outputs becomes unhealthy, the I/O processor generates a diagnostic alarm (fault). The I/O controller queries each cable connector's unique ID device on the terminal board. The ID device is a read-only chip that has the JR, JS, and JT connector locations, along with the serial number, board type, and revision number of the terminal board. A hardware incompatibility fault is produced when this chip is read by the I/O controller and a mismatch is discovered. Configuration The terminal board can be configured using jumpers. Refer to the installation diagram for the position of these jumpers. The available jumpers are as follows: Current input or voltage input can be chosen using the jumpers J1A through J8A. Whether the return is linked to common or left open is determined by jumpers J1B through J8B. Input current is chosen between 1 mA and 20 mA using the jumpers J9A and J10A. Whether the return is linked to common or left open is determined by jumpers J9B and J10B. Output 1 is adjusted to 20 mA or 200 mA by jumper J0. Characteristics Number of channels: 12 Temperature: -30 to 65o C (-22 to +149 oF) Size: 10.16 cm wide x 33.02 cmModule manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

IC600CB527M

DS3800XTFP1E1C

IS200DSPXH1DBC

IC693MDL640

IS220PDIAH1A 336A4940CSP1

IS200EGPAG1BCA

IC698CRE030

IC693CPU341

IC697CPX772

IS210BPPBH2BMD

IS200ERDDH1ABA

IS220PDOAH1A

DS200SDCIG1ABA

IC698CPE020

531X303MCPBBG1

IC687BEM731-AB

IC697CPM925

VMIVME-4140

DS200DMCBG1AED

IS200VCRCH1B

IC687RCM711

IS200TVIBH2BBB

IC670ALG310-JA

IC697CHS790

IS210SAMBH2AA

DS200SHVMG1AFE

IC660ELB912

IS220PPRFH1A

  • VIBRO-METER VM600Mk2/ VM600 XMx16 + XIO16T extended condition monitoring modules
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®