KONG -Y
NameDescriptionContent
Location:
product
GE IS200VVIBH1C Mark VI Function Module
❤ Add to collection

GE IS200VVIBH1C Mark VI Function Module

IS200VVIBH1C
U.S.$115989.00
U.S.$47830.00
U.S.$45438.50
U.S.$44481.90
Weight:0.000KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200VVIBH1C

Part Number IS200VVIBH1C Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS200VVIBH1C is a Vibration Monitor Board developed by General Electrics under Mark VI. 

Vibration probe signals from the TVIB or DVIB terminal board are processed by the Vibration Monitor board. Up to 14 probes can be connected to the terminal board directly. To the VVIB processor board, two TVIB can be connected. VVIB digitizes the various vibration signals and transmits them to the controller over the VME bus. For shaft vibration monitoring, the Mark VI system employs Bently Nevada probes. The vibration probes listed below are compatible: Proximity Velocity Acceleration Seismic Phase IS200VVIBH1C Installation To install the V-type board, follow these instructions. 

 Turn the VME processor rack off. To seat the board's edge connectors, slide them in, and push the top and bottom levers in with your hands. Tighten the captive screws on the front panel's top and bottom. IS200VVIBH1C Operation Bently Nevada Proximitor, Seismic, Accelerometer, and Velomitor probes are supported by the terminal board. The vibration probes are powered by the VVIB boards in either simplex or TMR mode. The probe signals are returned to VVIB, where they are A/D converted and sent to the controller via the VME bus. For Proximitor power, VVIB supplies -28 V dc to the terminal board. A diode high-select circuit in TMR systems selects the highest -28 V dc bus for redundancy. Individual excitation sources, -23 to -26 V dc, short circuit protected, are provided by regulators. Over discrete time periods, probe inputs are sampled at high speeds of up to 4600 samples per second.

The maximum and minimum values are accumulated, the difference (max-min) is used to calculate vibration, and the results are filtered. The resulting peak-to-peak voltage is scaled to produce engineering units (EU) (peak-to-peak) displacement for Proximitors inputs and EU (pk) velocity inputs from accelerometers, integrated outputs, seismics, and Velomitors. Vibration Monitoring Firmware The Vibration Monitoring on the VVIB is divided into three sections: Channels 3: Position data from Proximitors, wideband vibration data from Proximitors, accelerometers with integrated outputs, Velomitors, and Seismics can all be used on channels 1 through 3. When a Keyphasor probe is utilized, 1X and 2X information can be extracted from Proximitors viewing axial vibration information. In LM applications using accelerometers, tracking filters are commonly employed. Channels : Position information from Proximitors, wideband vibration information from Proximitors, Velomitors, and Seismics can all be found on Channels . When a Keyphasor probe is utilized, 1X and 2X information can be extracted from Proximitors viewing axial vibration information. Channels : Only position information is broadcast on Channels . Channel 13: Position feedback and Keyphasor feedback are supported by Channel 13. Wideband Vibration Filtering If input channels 14 through 21 are specified as vibration channels, the Wideband Vibration Filtering function runs at 4.6 kHz and 2.3 kHz, respectively. The FPGA that controls the A/D and multiplier circuit provide the vibration input for this purpose. The gap or position filter is a low pass filter with two poles and an 8 Hz cutoff frequency. 

The Gap Scaling and Limit Check function use the output of the gap filter, which is given in volts. The wideband vibration information can be shaped or conditioned based on the FilterType configuration parameter. For the Seismic and Velomitor sensor types, FilterTypes of Low-pass, Band-pass, or High-pass are used. All other sensor types use FilterType as None. 

Through the Filtrlpattn parameter, the Low-Pass filter can be configured for 2, 4, 6, or 8 pole attenuation behavior. Filtrlocutoff, a 3 dB cutoff frequency, is also adjustable. The High-pass filter can also be configured for 2, 4, 6, and 8 poles to sharpen the filter's attenuation characteristics via the Filtrhpattn parameter. The cutoff frequency, Filtrhpcutoff, can be configured. Vfout, the wideband filtered vibration output, is subjected to a minimum/maximum peak detect function. For Keyphasor-based speeds greater than 12 rpm, the capture window for the minimum/maximum detect is 160 milliseconds wide. 

The goal is to collect at least two cycles of vibration data in order to obtain an accurate peak-to-peak calculation. The unfiltered wideband vibration output is subjected to a second minimum/maximum peak detect function. Vmax and Vmin outputs are used to clamp the filtered vibration output peak-to-peak. Diagnostics Diagnostics execute a high/low (hardware) input signal limit check as well as a high/low system (software) limit check. In the field, the software limit check can be changed. If one of the X or Y probe pairs exceeds its limitations, a probe fault, alert, or trip condition occurs. Furthermore, if a probe error is discovered based on the dc component, the application software avoids a vibration trip (the ac component).VME VIBRATION CARD


  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives