KONG -Y
NameDescriptionContent
Location:
product
IS210DSCBH1A Manufacturer General Electric Country
❤ Add to collection

IS210DSCBH1A Manufacturer General Electric Country

IS210DSCBH1A
U.S.$96150.00
U.S.$4255.00
U.S.$4042.25
U.S.$3957.15
Weight:7.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS210DSCBH1A

Part Number IS210DSCBH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS210DSCBH1AA is a serial communication I/O board developed by GE. It is a part of Mark VI control system. 

The terminal board serves as a compact interface terminal board, specifically designed for DIN-rail mounting. It plays a crucial role in facilitating communication between various components within the system. FEATURES Connection to VSCA Board: Connects to the VSCA board using a 37-wire cable. The VSCA board serves as the communication hub, providing interfaces for external devices through various serial communication protocols such as RS-232C, RS-422, and RS-485. External Device Integration: Responsible for establishing communication with external devices, including intelligent pressure sensors such as Honeywell Pressure Transducers and Kollmorgen Electric Drives utilized for valve actuation. These devices play vital roles in system operation and control. Wiring Configuration: Wiring to external devices is conducted using shielded twisted pair cables, ensuring optimal signal integrity and minimizing electromagnetic interference. This configuration enhances the reliability and stability of communication between DSCB and external devices. Noise Suppression: Communication signals are equipped with onboard noise suppression mechanisms, which help mitigate interference and ensure reliable data transmission even in noisy environments. ID Chip Integration: An onboard ID chip is incorporated into the DSCB, serving the purpose of identifying the board to the VSCA for system diagnostic purposes. This feature enhances diagnostic capabilities and aids in troubleshooting potential issues within the system. CONFIGURATION The configuration of each of the six channels on the board involves several key aspects aimed at optimizing performance and ensuring reliable communication. Shield Connection Each channel features a jumper mechanism designed to connect the cable shield to ground via a capacitor. This configuration is particularly useful when the shield is grounded at the device end, serving to minimize electromagnetic interference (EMI) and ensure signal integrity. 

The specific jumper positions required for this connection are detailed in the Installation section of the documentation. Configuration Settings Beyond the shield connection, all other configuration settings for the channels are managed centrally on the board and through the designated toolbox interface. These settings encompass a range of parameters such as baud rate, data format, parity, and other communication protocol-related configurations. The board provides a comprehensive platform for adjusting these settings according to the specific requirements of the application. Installation Guidance Following the installation procedures ensures proper functionality and optimal performance of the communication channels. Toolbox Interface The toolbox interface offers a user-friendly platform for configuring and fine-tuning various aspects of channel operation. 

Through the toolbox, users can access and adjust configuration parameters conveniently, facilitating seamless integration and operation within the system. By adhering to the prescribed configuration procedures and leveraging the capabilities of the board and toolbox interface, users can effectively customize channel settings To suit their specific communication requirements while maintaining robustness and reliability. OPERATION The channels, specifically Ports 1 and 2, serve as the primary interfaces between the system and the Honeywell pressure transducers. These channels provide the necessary connectivity and control to facilitate data exchange and monitoring between the transducers and the broader system. To manage the RS422 multidrop signals effectively, three XDSA boards are employed as intermediate distribution boards. These boards play a crucial role in organizing and distributing signals across the system, ensuring seamless communication between the various components. 

The pressure transducers are strategically connected to the XDSA boards via designated ports, including P1, P2, P3, and P4. This configuration allows for a systematic arrangement of the transducers, optimizing signal flow and minimizing potential interference. Through the coordinated utilization of VSCA channels and XDSA boards, the operation achieves robust integration and communication between the Honeywell pressure transducers and the broader system. This setup enables efficient data acquisition, monitoring, and control, contributing to the overall functionality and performance of the system.DIN RAIL T.B.SERIAL



  • VIBRO-METER VM600Mk2/ VM600 XMx16 + XIO16T extended condition monitoring modules
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®