General Electric IS210DTRTH1A GE Manufacturing Policy Series Mark VI/VIe Function Module

IS210DTRTH1A
U.S.$7838.00
U.S.$3085.00
U.S.$2930.75
U.S.$2869.05
Weight:13.800KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS210DTRTH1A

Part Number IS210DTRTH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS210DTRTH1AA is a Primary Trip Relay Interface Board developed by GE. It is a part of Mark VI control system.

The board, designed as a DIN-rail mounted trip transition board, plays a crucial role in facilitating communication and control between the I/O (Input/Output) controller and the DRLY (Relay) board within the system architecture. Its primary function revolves around interfacing these components and redirecting trip functions from the I/O controller to the DRLY board, deviating from the conventional interaction with the TRPG board. Its DIN-rail mounting, interface capabilities between controllers and relays, and support for increased relay control underscore its significance in enhancing system flexibility, control, and capacity within the broader system framework. 

 FEATURES Interface Functionality: The board serves as an intermediary interface, enabling seamless communication between the I/O controller and the DRLY board. Its primary purpose is to redirect or transition three trip functions originating from the I/O controller to the DRLY board, thus bypassing the usual connection with the TRPG board. Mounting and Configuration: It is specifically designed for DIN-rail mounting, allowing for convenient installation and integration into the system's control panel or rack setup. Its configuration enables the connection of two controllers, collectively controlling a total of six relays on the DRLY board. This configuration expands the capacity for relay control beyond what is typically managed by a single controller.Enhanced Trip Functionality: By facilitating the redirection of trip functions to the DRLY board, the board expands the system's trip functionality, allowing for greater flexibility and customization in managing relays and trip-related operations.Inter-Board Communication: The board establishes a communication link between the I/O controller and the DRLY board, ensuring efficient relay control and coordination between these components. 

Role in Redundancy and Control Expansion: Its design supports redundancy and scalability within the system, enabling the connection of multiple controllers to increase relay control capacity, offering a reliable means to manage additional relays for expanded system functionality. 

INSTALLATION Mounting the DTRT Board: Designed to slide into a plastic holder specifically intended for DIN-rail mounting. This holder facilitates the secure attachment of the board onto the DIN-rail within the system's control panel or rack setup. 

Connection Setup with I/O Controller and DRLY Board: Three cables are employed to establish connections between the I/O controller and the DRLY board. These cables are plugged into the DC-37 connector on the board.The connections are organized in such a way that the first three DRLY circuits are controlled by the controller connected to J1 on the board. Meanwhile, the subsequent three DRLY circuits are controlled by the controller connected to J2. 

Grounding Connections on Terminal Block TB1: Terminal Block TB1 features an Euro-Block terminal. Within this terminal block, there are provisions for three screws allocated for the SCOM (ground) connection. To ensure proper grounding, it is recommended to connect the grounding wires to these terminals using the provided screws. It's essential to keep the ground connection as short as possible to minimize potential interference and ensure optimal grounding effectiveness. 

Optimizing Grounding Distance: The SCOM (ground) connection on the Euro-Block terminal block (TB1) should ideally maintain a minimal distance to achieve optimal grounding. A shorter distance reduces the potential for interference and improves the efficiency of the grounding mechanism. 

INPUTS Two DC-37 Pin Connectors (J4): These connectors are designated to receive cables from the VTUR (likely referring to a specific component or system). Each connector accommodates cables via a DC-37 pin configuration. Trip Relays: Each cable connected to the DC-37 pin connectors (J4) carries signals for three trip relays. This setup indicates that a total of three trip relays per cable are processed or controlled by the DTRT board. Therefore, across the two DC-37 pin connectors, there's a capacity for managing multiple trip relays, possibly related to specific functions or systems within the broader setup. 

OUTPUTS One DC-37 Pin Connector for Output (Cable to DRLY): The board features a single DC-37 pin connector designated for output. This connector is linked via a cable to the DRLY (Relay) board. Total of 6 Trip Relays: The output configuration implies that the board manages or controls a total of six trip relays through the cable connection to the DRLY board. These relays are likely responsible for specific trip functions or actions within the system.CARD ASSEMBLY DTRT

  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software
  • Bently 2300/20 and 2300/25 2300 Vibration Monitors
  • ABB NGC8206 Natural Gas Chromatograph Dual Unit
  • MOTOROLA MVME2400 TM VME Processor Modules
  • 5320 Series Foxboro DCS Control Network Ethernet Equipment
  • ExtremeSwitching™ 5420 Series
  • WOODWARD EGCP-3 Engine Generator Control Package LS (Load Sharing)
  • 5520 Series Universal Edge/Aggregation-Switch Platform
  • X440-G2 Series
  • EMERSON FloBoss™ S600 Flow Manager Specification Sheet
  • KONGSBERG RAIV400 Remote Analogue Input, Voltage
  • RMP420-Remote Multipurpose Input/Output Kongsberg
  • 610 serie ABB Feeder Protection REF610 Product Guide
  • Triconex 3351S2 Controller Features
  • HBRF Megamax – Emax2 Air Circuit Breaker ABB
  • ABB MEASUREMENT & ANALYTICS | DATA SHEET LS4000 Diode laser analyzer
  • Pressductor Pillowblock Load Cells Vertical Measuring PFCL 201 User manual
  • PARKER BFR5K Series
  • AC 900F controller ABB
  • Uniop ePAD05 and ePAD06 Technical description
  • Hitachi ABB Communication Unit 560CMR02
  • MOTOROLA MVME5500 Series VME Single-Board Computer
  • ABB Symphony Plus SD Series HPC800 controller
  • ABB AC800M Controller Hardware System
  • ABB AC800M PROFIBUS DP Installation System
  • ABB Freelance 800F AC800F Control systems
  • ABB Compact control system replaces PLC AC700F
  • abb Triguard SC300E 3BNP004720R101 TMR Safety Products
  • ABB Distributed busbar protection REB500
  • ABB Advant Controller 400 series
  • ABB MEASUREMENT & ANALYTICS | PRODUCT GUIDE
  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-