KONG -Y
NameDescriptionContent
Location:
product
IS210DVIBH1B Manufacturer General Electric Country
❤ Add to collection

IS210DVIBH1B Manufacturer General Electric Country

IS210DVIBH1B
U.S.$96150.00
U.S.$7555.00
U.S.$7177.25
U.S.$7026.15
Weight:3.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS210DVIBH1B

Part Number IS210DVIBH1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS210DVIBH1B is a vibration terminal board developed by GE. It is a part of the Mark VI control system. It is specifically designed to facilitate vibration monitoring in demanding industrial environments. 

Engineered for reliability and performance, the board offers versatile connectivity options and robust construction to meet stringent operational requirements. 

FEATURES Compact Design for DIN-Rail Mounting: The board features a compact form factor suitable for DIN-rail mounting, allowing for easy installation and integration within industrial enclosures or control panels. Its space-efficient design optimizes utilization of available space while ensuring compatibility with standard mounting configurations. 

Compliance with UL 1604 Specification: Designed to adhere to the UL 1604 specification, the board is certified for operation in hazardous environments classified as Class 1, Division 2. This certification underscores its suitability for use in areas where flammable gases, vapors, or liquids may be present, ensuring compliance with safety standards and regulations. 

Versatile Input Options: Offers a comprehensive array of input options to accommodate various vibration monitoring requirements. It accepts inputs from 13 vibration probes, comprising eight vibration inputs, four position inputs, and one keyphasor input. 

This versatile configuration enables comprehensive monitoring of vibration parameters critical for asset health assessment and predictive maintenance strategies. Connection to VVIB Processor Board: To facilitate communication and data processing, the board connects to the VVIB (Vibration Processor Board) using a 37-pin cable. This cable serves as the conduit for transmitting vibration data and control signals between the DVIB and VVIB boards, enabling seamless integration and synchronization of vibration monitoring functions. 

Compatibility with TVIB Terminal Board: Notably, the cables used to connect the board to the VVIB processor board are identical to those employed with the larger TVIB (Terminal Vibration Board). 

This standardization ensures compatibility and interchangeability between different terminal board configurations, offering flexibility in system design and scalability in deployment. 

Support for Multiple Boards: The VVIB processor board is capable of accommodating two boards simultaneously, enabling expanded monitoring capabilities within the system. This scalability allows for the simultaneous monitoring of multiple vibration points, enhancing the granularity and depth of vibration analysis for improved asset management and condition monitoring. 

INSTALLATION Mounting the Plastic Holder: Begin by sliding the board into the plastic holder provided. The holder is designed for easy attachment to a DIN-rail, a standard mounting solution in industrial environments. Secure the plastic holder onto the DIN-rail to provide a stable base for the DVIB board. 

Wiring Vibration Probes: The vibration probes, essential for monitoring vibration parameters, are wired directly to the terminal block on the board. This terminal block typically features 42 terminals to accommodate multiple probes. Use 18 AWG shielded twisted triplet wiring for reliable signal transmission and noise immunity. Grounding (SCOM) Connection: Locate the ground (SCOM) connection points on the board. Ensure that the ground connection is established using a suitable wire gauge, following recommended grounding practices. Use two screws for the SCOM connection to ensure a secure and reliable ground connection. 

Considerations for Ground Connection: When establishing the ground connection, prioritize minimizing the distance between the ground points and the SCOM connection. This helps mitigate the risk of signal interference and ensures optimal performance of the vibration monitoring system. Final Checks: Before finalizing the installation, perform thorough checks to ensure all connections are secure and properly terminated. Verify the integrity of the wiring and ground connections to prevent potential issues during operation. 

Integration with System: Once the board is securely mounted and all connections are verified, integrate it into the larger system architecture. Ensure that it is properly connected to the VVIB processor board using the designated 37-pin cable for seamless communication and data transmission. 

Testing and Calibration: After installation, conduct comprehensive testing and calibration procedures to validate the functionality of the board and ensure accurate vibration monitoring. Verify proper communication with the VVIB processor board and confirm the responsiveness of connected vibration probes. 

Documentation and Maintenance: Document the installation process and keep detailed records for future reference. Regular maintenance and inspection of the DVIB board and associated components are essential to ensure continued reliability and performance. 

DIAGNOSTICS Hardware and Software Limit Checks: Diagnostic tests incorporate a high/low limit check on the probe input signals, assessing both hardware and software parameters. These limits are established to detect abnormalities and deviations from expected values. Any breaches of these limits result in the generation of faults, signaling potential issues that require attention. 

Probe Fault Detection: Special attention is given to probe inputs, where fault, alarm, or trip conditions are triggered if either an X or Y probe pair exceeds its predefined limits. This comprehensive monitoring ensures timely detection of anomalies in vibration levels or other measured parameters, facilitating proactive maintenance and troubleshooting. Position Monitoring: Position inputs for thrust wear protection, differential expansion, and eccentricity are meticulously monitored, akin to vibration inputs. However, in this case, only the DC component is utilized for position indication. If the maximum limit is surpassed, a fault is promptly generated, indicating potential issues in machinery operation or component integrity.TERMINAL BOARD & BRACKET



  • Tricon 8120E card is in stock.
  • NE870 Network Router ABB 3BSE080239R1
  • ALSTOM V4561484-0100 Amplifier Module Rev 7 Pcb Circuit Board
  • Model 10959-201 and -203 Wall-Mount Audio Messenger Interfaces
  • HIMA X-SB 01985210207 24VDC System bus module
  • HIMA X-FAN 18 03 High-efficiency cooling plate fan
  • HIMatrix F3 AIO8/4 01 HIMA Compact Controller
  • 3BHE039770R0102 PP D539 A102: AC 800PEC Contr. Device
  • ABB CMC 70, Controller, SW-Vers. 1.61/2.11
  • GE SR760-CASE 750/760Feeder Management Relay® Instruction Manual
  • ABB REG670 C30 Version 2.0 General Information
  • REF543KM127BAAA ABB FEEDER TERMINAL
  • Danaher driver SAM-DA-400/480-07N-P4N-F
  • GE FANUC/ALSTOM LC106-1- LE108 LC105 LC106 Spot model
  • ALSTOM AB121丨AY00000000266/B technical parameter
  • GE ALSTOM LE109A-1 control card data
  • GE ALSTOM IR139-1丨063022350 丨80801419 Control card. data
  • Alstom Control Set-UT150-1 Kongjiang-spot
  • ALSTOM AL132丨AL132A Control Card
  • PM1118丨ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • DEIF DLQ72-PC-PY ROLLS-ROYCE K85240 PITCH INDICATOR 10V
  • Rolls-Royce Marine R10I53S/R10I53S Panel Computer 98H0101A0000I Rev 1.9
  • ROLLS-ROYCE P001240-1 display REV 2
  • ROLLS-ROYCE RRDIO15 I/O ALARM MODULE
  • Rolls-royce UN930 Digital Display Controller 24V
  • ROLLS-ROYCE MARINE LAUER LCA 325.P2 PROFIBUS-DP NET DISPLAY PANEL UN924
  • ROLLS-ROYCE MARINE AS 5880-PC1002 STEERING GEARS-TENFJORD PCB card
  • ROLLS-ROYCE UN31 ECR panel 000127603
  • Rolls-royce ship AS UN991.1 distributing plate
  • ROLLS-ROYCE 5045 K THRUSTER CONTROLLER PANEL
  • Rolls-Royce SLIO 02 Canman controller network
  • Rolls-Royce E-1071 automatically displays 07918 B UN 921 ECR 24VDC
  • ROLLS ROYCE PCC1030C ULSTEIN panel controller card
  • ROLLS-ROYCE KAMEWA PROPELLERS control room panel basic R160637A
  • ROLLS-ROYCE UN925 Panel Controller
  • Rolls-royce Marine AS UN921 OPRETOR panel
  • Rolls-Royce Marine r10I53s/R10I53S Panel Computer 98H0101A0000I
  • ROLLS-ROYCE H1111.0104 ocean controller P/N:75669
  • Rolls-Royce H1111.0203 Marine Controller Version 2.2
  • Rolls-Royce H1111.0102 Marine Controller
  • Rolls-Royce H1127-0101 Marine Controller 00068308H6045/433
  • Rolls-Royce H1111.0103 Marine Controller 75669 Version 2.2
  • EMERSON KJ3221X1-BA2 VE4035S2B1 ATEX Instruction Sheet
  • EMERSON VE4017P0 M-series FOUNDATION™ Fieldbus I/O
  • A6740 16-Channel Output Relay Module for the AMS 6500 Machinery Health Monitor
  • EMERSON A6120 Protection Cards for AMS 6500 Classic Systems
  • A6000 series A6125 electric vibration monitor Emerson
  • EMERSON A6000 series control card A6410
  • EMERSON A6370 Overspeed Protection Monitor
  • ABB 3BHB015651P0001 DKTFM418B Power converter assembly
  • Westingouse Ovation 5X00500G01 Speed detector module
  • Emerson 5X00875G01 Analog input EMOD module
  • UNIOP ETT-VGA-0045 HMI touch unit with colour graphic display and VGA resolution. Available with high-quality TFT
  • General Electric Mark VI series IS200JPDBG1A IS200JPDBG1ABB printed circuit
  • General electric IS200EDISG1A distribution board
  • IS400TDBTH6A Mark* VIe control system Extended product life cycle description
  • DS200DCFBG1BLC General Electric Power Supply Board
  • 5485C Velocity Sensor Metrix
  • ABB 3BSE031155R1 BC810K02 CEX-bus Interconnection Unit
  • DCS602-0250-51-15 ABB DCS 600 Overload Capability
  • DCS602-0520-51/15 ABB Permanent drive
  • 853-032776-001 Lam Research Paddle Lifter
  • Modbus Plus Communication Module MVI56-MBP
  • PLC board (head) module KEBA CPU IP70
  • DS200DSFBG1A Driver/Shunt Feedback Board technical specifications
  • DS200DPCAG1ADB IOS + Power Connect Board Technical Specifications
  • DS200DPCAG1A IOS & Power Connect Card Assembly
  • Hirschmann MM20-P9P9T1T1SAHH Media Converters
  • Hirschmann MM20-P9P9P9P9SAHH In installation instructions
  • Hirschmann MM4-2TX/SFP Media Converters
  • Hirschmann MM4-4TXSFP-datasheet
  • Hirschmann MM3-1FXL23TX1_techdata MM3-1FXL2/3TX1
  • Hirschmann MM3-4FXS2 PowerMICE series industrial switch products
  • Hirschmann MM3-2FXS2/2TX1 Media Converters
  • MM3-1FXM2/3TX1 Hirschmann Ethernet & Communication Modules
  • Hirschmann MM3-4TX5 Media module
  • Hirschman MM2-2FXM3/2TX1 Media Module article will analyze the technical features of this product in detail
  • Hirschmann MM2-4TX1 Performance parameters of compact and modular managed Ethernet switch
  • MS4128-L3E ATEX Power mouse, modular, managed industrial Ethernet switch
  • Hirschmann MS4128-L2P ATEX 943009101, Power MICE, modular, managed Industrial
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SAHH
  • Hirschmann MM20-T1T1T1T1SZHH Managed Ethernet switch
  • Hirschmann MM20-M4T1T1T1SAHH Media converter
  • Detailed explanation of Hirschmann GMM20-mmmmmev9HHS9 xx.x.xxx Ethernet module
  • Hirschmann MM20-M2M2M2T1SAHH Management Ethernet Switch Function and Configuration Guide
  • Product introduction and technical specifications of Hirschmann MM20-M2M2M2M2EAHH media converter
  • Hirschmann MM20-M4M49999TAHH Media converter
  • Hirschmann MM20-Z6Z6Z6Z6TAHH Media converter
  • Media converter MM20-M2M29999EAHH Data
  • Media converter MM20-G2T1T1T1SAHH Hirschmann
  • Hirschmann Media converter MM20-M2T1T1T1TAHH
  • Hirschmann Ethernet module GMM GMM20-VVVVVVVVSY9HHS999.9.XX
  • Managed Ethernet Switch MM20-M4M4M4M4TAHH
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SSHH
  • Hirschmann Managed Ethernet Switch MM20-Z6Z6Z6Z6SSHH
  • Media converter MM20-T1T1T1T1TAHH Hirschmann
  • Hirschmann Media converter MM20-M4M4T1T1EAHH
  • MM20-M4M4M4M4EAHH Hirschmann Media converter
  • Hirschmann Media converter MM20-M2M2M2M2SAHH
  • Hirschmann Managed Ethernet Switch MM20-S2S2T1T1SYHH
  • ABB SDCS-POW-4 POWER SUPPLY
  • AMAT 0090-35032 ARSINE DETECTOR 0-1000PPB
  • SMC XLFD-100D-X1236 high vacuum valve 0.4 ~ 0.7MPa 5 ~ 60°C
  • 50DW412745 Control Module United Technologies Carrier
  • Carrier 50DW404638 Control module CEAS430189-02
  • TRICONEX 2481 I/O Module
  • WARNER ELECTRIC HMCS2000-PRG Programmer
  • WARNERELECTRIC MCS2000-ECA Digital control
  • Related Manuals for WAGO WAGO-I/O-IPC 758-870 and 58-873Series
  • IOC4T-RLC16 Vibro-Meter company VM600 system and sensor technical data
  • MEGGITT VIBRO-METER 200-510-076-114 VM600 MPC4 Descriptive data
  • IPC704 Signal conditioner MEGGITT VIBRO-METER IPC704 244-704-000-032 AMP
  • GSI127 galvanic separation unit MEGGITT VIBRO-METER GSI 127 244-127-000-017 A1-B02 MODULE
  • ABB Relion® 650series REC650/REL650/RET650/REB 650/REQ 650
  • Rexroth Sercos III analog, axis module R-ILB S3 AI12 AO4 SSI-IN4
  • DS200DMCBG1ABB DOS DUP Processor Board
  • DS200DMCAG1AAA Gen/Log/Key Interface Board
  • DS200DKLBG1ABB Power Connect Board
  • General Electric DS200DENCF1BDE01 EEPROM with Firmware
  • DS200DDTBG2ABB LCI Auxiliary I/O Terminal Board
  • DS200DCVAG1A DC Power and Instrumentation Board
  • DS200DCPAG1 DC Power Board GE General Electric
  • DS200DCFBG1B DC Feedback Power Supply Board
  • DS200DCFBG1AAA DC Power Feedback Board
  • DS200DACAG1 TC/DC AC/DC Convertor Board
  • DS200CVMAG3AEB Cap/Fuse Voltage Monitor Board
  • DS200CVMAG1AEB Capacitor Voltage Monitor Assembly
  • DS200CTBAG1A Analog Termination Module