IS210TREGH4B GE Manufacturing Policy Series Mark VI/VIe Function Module
❤ Add to collection

IS210TREGH4B GE Manufacturing Policy Series Mark VI/VIe Function Module

IS210TREGH4B
U.S.$4587.00
U.S.$5985.00
U.S.$5685.75
U.S.$5566.05
Weight:4.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS210TREGH4B

Part Number IS210TREGH4B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS210TREGH4B is an emergency trip terminal board assembly developed by General Electrics. It is a part of Mark VI control system. 

The TREG system plays a critical role in ensuring the safety and functionality of various emergency functions within a larger system. 

Specifically, it serves as the power source for three emergency trip solenoids, all of which are under the precise control of the I/O controller. Features Responsible for supplying power to the three emergency trip solenoids. These solenoids are crucial for triggering essential safety measures in response to specific conditions or events. It is designed to accommodate up to three trip solenoids, and these solenoids are connected between the TREG and TRPG terminal boards. Each solenoid is strategically positioned to respond to distinct emergency scenarios. Provides the positive side of the direct current (DC) power to the connected solenoids. 

This positive power supply is essential for energizing and activating the solenoids when required. It is designed to accommodate up to three trip solenoids, and these solenoids are connected between the TREG and TRPG terminal boards. Each solenoid is strategically To complete the circuit and ensure proper functionality, the TRPG terminal boards come into play by providing the negative side of the DC power. 

This complementary power source from TRPG is essential for enabling the solenoids to perform their emergency trip functions effectively. It is designed to accommodate up to three trip solenoids, and these solenoids are connected between the TREG and TRPG terminal boards. Each solenoid is strategically The I/O controller takes on a central role in the operation of this system. It is responsible for overseeing and managing several critical functions: Emergency Overspeed Protection: The I/O controller monitors the speed of the system and can engage emergency overspeed protection measures to prevent dangerous acceleration. Emergency Stop Functions: In case of any critical issues or emergencies, the I/O controller can initiate emergency stop functions to halt the system immediately. Relay Control: TREG hosts a set of 12 relays, and the I/O controller is in charge of controlling these relays. Nine of these relays are organized into three groups of three. These relay groups work in a voting system, where the inputs are assessed collectively, ensuring redundancy and reliability. 

This mechanism allows for effective control of the three trip solenoids, enhancing safety and response capabilities. Operation The operation of the TREG system is highly streamlined and reliant on the precise control provided by the I/O controller. This control scheme ensures the safety and functionality of the entire system, with minimal external connections to the control modules. I/O Controller Dominance: The I/O controller serves as the central brain of the system, exercising complete authority over its functions. It orchestrates and coordinates all actions and responses, making it a crucial component for the system's overall performance and safety. 

Control Module Connections: TREG maintains a minimalist approach when it comes to external connections. 

The only two connections it has to the control modules are as follows: J2 Power Cable: This cable is responsible for supplying power. It acts as the lifeline that ensures TREG remains operational and ready to respond to emergency situations. This power connection is fundamental to keeping the system active and prepared for action. 

Trip Solenoid Connections: The primary means through which TREG interacts with the wider system is through the trip solenoids. These solenoids are crucial for initiating emergency shutdowns or other critical actions when necessary. The control signals from the I/O controller are transmitted through these solenoids, enabling precise and rapid responses to emergency conditions. 

Simplex System Functionality: In simplex systems, an additional cable, known as the third cable, comes into play. This cable carries a trip signal from J1 to the TSVO terminal board. This trip signal is particularly important because it facilitates a servo valve clamp function when the turbine undergoes a trip event. This feature is critical for ensuring that the turbine is safely brought to a stop or controlled state during emergency scenarios. In essence, TREG's operation is characterized by its reliance on the I/O controller for control and coordination. 

Its connections are kept minimal and purpose-driven, with power supply through the J2 cable and communication via the trip solenoids. In simplex systems, the introduction of the third cable adds an extra layer of safety by enabling precise control of the servo valve during turbine trip events. This careful design and control strategy make TREG an integral component in maintaining the safety and reliability of the larger system it is a part of. 

 Attributes Trip interlock isolation: Optical isolation to 1500 V on all inputs Trip interlock filter: Hardware filter, 4 ms Trip interlock ac voltage rejection: 60 V rms Solenoid response time: Solenoid L/R time constant is 0.1 second Solenoid Trip Tests Solenoid Trip Tests involve the utilization of application software within the controller to execute tests on trip solenoids. 

These tests can be conducted online, enabling the individual tripping of each solenoid sequentially. This can be achieved either through the PTR (Protection, Trip, and Release) relays from the controller or via the ETR (Emergency Trip Relay) relays from the protection module. For confirmation of solenoid operation, a contact from each solenoid circuit is connected back as a contact input, providing a positive indication that the solenoid has indeed tripped. Furthermore, the system incorporates primary and emergency offline overspeed tests. These tests serve the purpose of validating genuine trip occurrences by simulating overspeed conditions through software. 

This verification process ensures the reliability and functionality of the solenoids in response to critical operational parameters, bolstering the overall safety and efficiency of the system.RELAY MODULE

  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software
  • Bently 2300/20 and 2300/25 2300 Vibration Monitors
  • ABB NGC8206 Natural Gas Chromatograph Dual Unit
  • MOTOROLA MVME2400 TM VME Processor Modules
  • 5320 Series Foxboro DCS Control Network Ethernet Equipment
  • ExtremeSwitching™ 5420 Series
  • WOODWARD EGCP-3 Engine Generator Control Package LS (Load Sharing)
  • 5520 Series Universal Edge/Aggregation-Switch Platform
  • X440-G2 Series
  • EMERSON FloBoss™ S600 Flow Manager Specification Sheet
  • KONGSBERG RAIV400 Remote Analogue Input, Voltage
  • RMP420-Remote Multipurpose Input/Output Kongsberg
  • 610 serie ABB Feeder Protection REF610 Product Guide
  • Triconex 3351S2 Controller Features
  • HBRF Megamax – Emax2 Air Circuit Breaker ABB
  • ABB MEASUREMENT & ANALYTICS | DATA SHEET LS4000 Diode laser analyzer
  • Pressductor Pillowblock Load Cells Vertical Measuring PFCL 201 User manual
  • PARKER BFR5K Series
  • AC 900F controller ABB
  • Uniop ePAD05 and ePAD06 Technical description
  • Hitachi ABB Communication Unit 560CMR02
  • MOTOROLA MVME5500 Series VME Single-Board Computer
  • ABB Symphony Plus SD Series HPC800 controller
  • ABB AC800M Controller Hardware System
  • ABB AC800M PROFIBUS DP Installation System
  • ABB Freelance 800F AC800F Control systems
  • ABB Compact control system replaces PLC AC700F
  • abb Triguard SC300E 3BNP004720R101 TMR Safety Products
  • ABB Distributed busbar protection REB500
  • ABB Advant Controller 400 series
  • ABB MEASUREMENT & ANALYTICS | PRODUCT GUIDE
  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-
  • 3BHB007441P0001 LDSTA-01 ABB inverter control CPU driver board