KONG -Y
NameDescriptionContent
Location:
product
IS220PDOAH1A GE Manufacturing Policy Series Mark VIe Function Module
❤ Add to collection

IS220PDOAH1A GE Manufacturing Policy Series Mark VIe Function Module

IS220PDOAH1A
U.S.$1159.00
U.S.$586.00
U.S.$556.70
U.S.$544.98
Weight:3.550KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS220PDOAH1A

Part Number IS220PDOAH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PDOAH1A is a Discrete Output Pack and is part of the GE Speedtronic Mark VIe gas turbine control system. 

It connects one or two I/O Ethernet networks to a discrete output terminal board via an electrical interface. The pack includes a processor board shared by all Mark VIe distributed I/O packs as well as an acquisition board dedicated to the discrete output function. IS220PDOAH1A Functional Description The pack can control up to 12 relays and accepts feedback from the terminal board. 

There are magnetic relays (TRLYH1B, C, D, and F terminal boards) and solid-state relays (TRLYH1E boards) available. The pack is powered by three-pin power input and two RJ45 Ethernet connectors. Output is via a DC-37 pin connector that is directly connected to the associated terminal board connector. Indicator LEDs provide visual diagnostics, and an infrared port allows for local diagnostic serial communications. Compatibility It works with six different types of discrete (relay) output terminal boards, including TRLY and SRLY boards, but not DIN-rail mounted DRLY boards. The number of I/O packs used in a signal path is referred to as the control mode: Simplex employs a single I/O pack and one or two network connections. Dual employs two I/O packs with one or two network interfaces. TMR employs three I/O packs, each with one network connection. 

 IS220PDOAH1A Installation Installing the PDOA pack: Securely mount the terminal board of choice. Insert one simplex PDOA I/O pack or three TMR PDOA I/O packs directly into the terminal board connectors. Use the threaded studs next to the Ethernet ports to mechanically secure the packs. The studs fit into a terminal board-specific mounting bracket. The bracket should be positioned so that no right-angle force is applied to the DC37 connector between the pack and the terminal board. The adjustment should only be needed once during the product's lifetime. Depending on the system configuration, connect one or two Ethernet cables. The pack will work with either port. When using dual connections, it is common practice to connect ENET1 to the network associated with the R controller. Connect the pack to power by plugging in the connector on the pack's side. 

This connector does not need to be inserted with the power disconnected from the cable because the I/O pack has an inherent soft-start capability that controls current inrush on power application. Configure the I/O pack as required. IS220PDOAH1A Operation Processor The processor board is linked to an acquisition board that is dedicated to the I/O pack function. When input power is applied, the soft-start circuit increases the voltage available on the processor board. The local power supplies are turned on in sequence, and the processor reset is disabled. After completing self-test routines, the processor loads application code specific to the I/O pack type from flash memory. The application code reads board ID information to ensure that the application code, acquisition board, and terminal board are all correctly matched. With a good match, the processor attempts to establish Ethernet communications, beginning with a network address request. The address request employs the industry-standard dynamic host configuration protocol (DHCP) and the terminal board's unique identification. Following Ethernet initialization, the processor programs the onboard logic executes the application, and allows the acquisition board to start up. Relay Command Signals The PDOA relay command signals are used as the first stage of signal conditioning and level shifting to connect terminal board outputs to control logic. 

Each output is an open collector transistor circuit with a current monitor that detects when the output is selected and connected to a load. When an output is picked up and connected to the terminal board, the status LEDs and monitor outputs illuminate. If the output is selected but no load is detected, the status LED will turn off and the monitor line will be false. Output Enable During power application, all outputs are disabled until a series of internal self-tests are completed. An enable line reflects the status of all required operating conditions. This function provides an independent path to ensure that relays remain dropped out during power-up and initialization. IS220PDOAH1A Features The number of relay channels in a single PDOA pack is 12 relays (different types depending on the terminal board) 15-pack inputs are monitored by a relay and a coil. The type of terminal board used, as determined by the ID chip, influences the selection of monitor feedbacks. The I/O pack response time is approximately 6 ms from Ethernet command to output.IO PACK, CONTACT OUT

  • SAUTER AXT 201. 211: Thermal actuator for unit valves with stroke
  • SAUTER AXS 215S: Continuous actuator for unit valves, with stroke
  • SAUTER AXM 217S: Motorised actuator for unit valves with positioner
  • SAUTER AVM 321S, 322S: Valve actuator
  • SAUTER AVM234S: SUT valve actuator with positioner
  • SAUTER AVM 105. 115: Valve actuator
  • SAUTER AVF234S: SUT valve actuator with spring return
  • SAUTER AVF 124: Actuator with spring return
  • SAUTER AKM115SAF332: Smart Actuator for ball valve, BACnet/IP
  • SAUTER AKM115SA: Smart Actuator for ball valve
  • SAUTER AKM105S, 115S: Rotary actuator with SAUTER Universal
  • SAUTER AKM 105. 115: Rotary actuator for ball valve
  • SAUTER AVM234S: SUT valve actuator with positioner
  • SEL SEL-T401L Ultra-High-Speed Line Relay
  • SEL-SEL-T400L Time-Domain Line Protection
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-787 Transformer Protection Relay
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL-SEL-487E Transformer Protection Relay
  • SEL-SEL-400G Advanced Generator Protection System
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700BT Motor Bus Transfer Relay
  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 XMx16 + XIO16T extended condition monitoring modules
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit